Vertical root fracture resistance and dentinal crack formation of root canal-treated teeth instrumented with different nickel-titanium rotary systems: an in-vitro study

被引:10
|
作者
Lin, Galvin Sim Siang [1 ]
Singbal, Kiran Prabhakar [2 ]
Noorani, Tahir Yusuf [1 ]
Penukonda, Raghavendra [2 ]
机构
[1] Univ Sains Malaysia, Sch Dent Sci, Conservat Dent Unit, Hlth Campus, Kota Baharu 16150, Kelantan, Malaysia
[2] Malaysian Allied Hlth Sci Acad MAHSA Univ, Fac Dent, Dept Conservat Dent, Bandar Saujana Putra 42610, Selangor, Malaysia
关键词
Canal taper; Dentinal crack; Nickel-titanium; Root canal; Vertical root fracture; CORONAL FLARING INSTRUMENTS; PROTAPER UNIVERSAL; TAPER; PREVALENCE; QUALITY; FORCES;
D O I
10.1007/s10266-021-00643-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To compare the vertical root fracture (VRF) resistance of root canal-treated teeth instrumented with four different nickel-titanium (NiTi) rotary file systems and examine the dentinal crack pattern and direction using a new classification. Eighty mature mandibular premolars were selected and decoronated, leaving 13 mm of the root. The root samples were mounted in acrylic resin and divided randomly into five groups of different NiTi file systems: Group 1-control, Group 2-T-Pro, Group 3-HyFlex CM, Group 4-TG6 and lastly Group 5-ZenFlex. Samples in Group 2 and Group 3 were instrumented up to size 25/0.04, whereas Group 4 and Group 5 were instrumented up to size 25/0.06. Obturation was performed with AH Plus sealer and gutta-percha using single cone technique. Subsequently, all samples were subjected to occlusal compressive force until they were fractured. The force (N) needed to cause root fracture was recorded. The crack patterns and directions were also inspected under magnification and classified using a new and simple classification. The highest (VRF) resistance was noted in the control group (453.15 +/- 92.23 N), followed by T-Pro (387.43 +/- 76.81 N), HyFlex CM (381.88 +/- 52.73 N), ZenFlex (369.15 +/- 89.41 N) and finally TG6 (346.05 +/- 72.08 N), but there was no significant difference between T-Pro and HyFlex (P = 0.438). A significantly higher prevalence (P = 0.001) of Type 1 crack pattern was observed, especially in samples instrumented with TG6. Majority of the cracks ran buccolingually except in some samples instrumented with ZenFlex (P = 0.898). Smaller file taper increased the VRF resistance of root canal-treated teeth. Majority of the dentinal crack exhibited Type 1 pattern and ran buccolingually.
引用
收藏
页码:106 / 112
页数:7
相关论文
共 31 条
  • [1] Vertical root fracture resistance and dentinal crack formation of root canal-treated teeth instrumented with different nickel–titanium rotary systems: an in-vitro study
    Galvin Sim Siang Lin
    Kiran Prabhakar Singbal
    Tahir Yusuf Noorani
    Raghavendra Penukonda
    Odontology, 2022, 110 : 106 - 112
  • [2] Comparison of the Resistance of Teeth Instrumented with Different Nickel-Titanium Systems to Vertical Root Fracture: An In Vitro Study
    Cicek, Ersan
    Aslan, M. Ali
    Akkocan, Oguzhan
    JOURNAL OF ENDODONTICS, 2015, 41 (10) : 1682 - 1685
  • [3] Vertical root fracture resistance and crack formation of root canal-treated teeth restored with different post-luting systems
    Rathke, Andreas
    Frehse, Henry
    Hrusa, Beatrice
    ODONTOLOGY, 2022, 110 (04) : 719 - 725
  • [4] Vertical root fracture resistance and crack formation of root canal-treated teeth restored with different post-luting systems
    Andreas Rathke
    Henry Frehse
    Beatrice Hrusa
    Odontology, 2022, 110 : 719 - 725
  • [5] Effect of Different Heat-treated Nickel-Titanium Files on Vertical Root Fracture Resistance
    Furuncuoglu, Fatma
    Kalyoncuoglu, Elif
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2021, 22 (02): : 157 - 163
  • [6] Comparative Study of Different Novel Nickel-Titanium Rotary Systems for Root Canal Preparation in Severely Curved Root Canals
    Capar, Ismail Davut
    Ertas, Huseyin
    Ok, Evren
    Arslan, Hakan
    Ertas, Elif Tarim
    JOURNAL OF ENDODONTICS, 2014, 40 (06) : 852 - 856
  • [7] Influence of optimum torque reverse motion on dentinal cracks after root canal preparation with two nickel-titanium rotary systems
    Khallaf, Maram
    Hassan, Reham
    CONTEMPORARY CLINICAL DENTISTRY, 2022, 13 (02) : 183 - 188
  • [8] Unveiling the mechanical performance of partially replaced coronal restorations in root canal-treated teeth: an in-vitro study
    Turky, Mohammed
    Plotino, Gianluca
    Mahmoud, Nermin Alsayed
    BMC ORAL HEALTH, 2024, 24 (01):
  • [9] Potential Relationship between Design of Nickel-Titanium Rotary Instruments and Vertical Root Fracture
    Kim, Hyeon-Cheol
    Lee, Min-Ho
    Yum, Jiwan
    Versluis, Antheunis
    Lee, Chan-Joo
    Kim, Byung-Min
    JOURNAL OF ENDODONTICS, 2010, 36 (07) : 1195 - 1199
  • [10] Root Canal Surface Strain and Canal Center Transportation Induced by 3 Different Nickel-Titanium Rotary Instrument Systems
    Liu, Wenzhe
    Wu, Buling
    JOURNAL OF ENDODONTICS, 2016, 42 (02) : 299 - 303