Improved traceability of pH measurements

被引:0
|
作者
Spitzer, P
Eberhardt, R
Schmidt, I
Sudmeier, U
机构
来源
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traceability is a prerequisite for the comparability and uniformity of measurements. Although pH-measurements are carried out on a large scale in laboratory and industry, the problems involved in the traceability of pH values have not adequately been solved in the past. The comparability of pH measurements is limited, among other parameters, by the accuracy of the pH values of the standard buffer solutions used to calibrate the pH meter-electrode assemblies. The measured pH(X) value must be traceable to primary standard pH(PS) values through an unbroken chain of comparisons, all values having stated uncertainties. A new primary standard measurement device for pH is used to certify primary pH reference materials from which these secondary reference materials can be derived.
引用
收藏
页码:178 / 181
页数:4
相关论文
共 50 条
  • [1] Improved traceability of pH measurements
    Physikalische-Technische, Bundesanstalt , Bundesalle 100, 38116 Braunschweig, Germany
    Fresenius J Anal Chem, 3-4 (178-181):
  • [2] Traceability of pH Measurements
    Camoes, Maria Filomena
    Spitzer, Petra
    SYMPOSIUM IN HONOR OF RICHARD BUCK, 2014, 61 (15): : 31 - 37
  • [3] Improved reliability of pH measurements
    Spitzer, P
    Werner, B
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (05) : 787 - 795
  • [4] Improved reliability of pH measurements
    Petra Spitzer
    Barbara Werner
    Analytical and Bioanalytical Chemistry, 2002, 374 : 787 - 795
  • [5] Traceability of pH to the Mole
    Camoes, Maria Filomena
    Anes, Barbara
    WATER, 2015, 7 (08): : 4247 - 4255
  • [6] Invited Article: Expanded and improved traceability of vibration measurements by laser interferometry
    von Martens, Hans-Juergen
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (12):
  • [7] Traceability of pH measurements by glass electrode cells: performance characteristic of pH electrodes by multi-point calibration
    R. Naumann
    Ch. Alexander-Weber
    R. Eberhardt
    J. Giera
    P. Spitzer
    Analytical and Bioanalytical Chemistry, 2002, 374 : 778 - 786
  • [8] Traceability of pH measurements by glass electrode cells: performance characteristic of pH electrodes by multi-point calibration
    Naumann, R
    Alexander-Weber, C
    Eberhardt, R
    Giera, J
    Spitzer, P
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (05) : 778 - 786
  • [9] The traceability of analytical measurements
    M. Buzoianu
    H. Y. Aboul-Enein
    Accreditation and Quality Assurance, 1997, 2 : 11 - 17
  • [10] Traceability of measurements in chemistry
    Alexandrov, YI