Laboratory results of a 3rd generation roof bolter canopy air curtain for respirable coal mine dust control
被引:15
作者:
Reed, W. R.
论文数: 0引用数: 0
h-index: 0
机构:
NIOSH, Ctr Dis Control & Prevent, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USANIOSH, Ctr Dis Control & Prevent, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USA
Reed, W. R.
[1
]
Joy, G. J.
论文数: 0引用数: 0
h-index: 0
机构:
NIOSH, Ctr Dis Control & Prevent, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USANIOSH, Ctr Dis Control & Prevent, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USA
Joy, G. J.
[1
]
Shahan, M.
论文数: 0引用数: 0
h-index: 0
机构:
NIOSH, Ctr Dis Control & Prevent, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USANIOSH, Ctr Dis Control & Prevent, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USA
Shahan, M.
[1
]
Klima, S.
论文数: 0引用数: 0
h-index: 0
机构:
NIOSH, Ctr Dis Control & Prevent, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USANIOSH, Ctr Dis Control & Prevent, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USA
Klima, S.
[1
]
Ross, G.
论文数: 0引用数: 0
h-index: 0
机构:
JH Fletcher & Co Inc, 402 High St, Huntington, WV 25705 USANIOSH, Ctr Dis Control & Prevent, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USA
Ross, G.
[2
]
机构:
[1] NIOSH, Ctr Dis Control & Prevent, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USA
[2] JH Fletcher & Co Inc, 402 High St, Huntington, WV 25705 USA
来源:
INTERNATIONAL JOURNAL OF COAL SCIENCE & TECHNOLOGY
|
2019年
/
6卷
/
01期
关键词:
Roof bolter;
Respirable dust;
Canopy air curtain;
Coal mining;
D O I:
10.1007/s40789-019-0237-6
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
Testing was completed on an earlier roof bolter CAC that used slots to provide a perimeter airflow. NIOSH tested it due to its unique design that differed from canopies that provided uniform airflow. Based upon NIOSH recommendations from the earlier testing, a 3rd generation roof bolter CAC has been developed by J.H. Fletcher & Co. The changes to this CAC involve design modifications to the plenum outlets, using a single row of outlets on the perimeter and a different material for the plenum. This laboratory testing was a continuation of the original perimeter slotted CAC design. Using gravimetric and instantaneous sampling of respirable dust concentrations underneath and outside of the CAC, the laboratory testing was completed using three different blower fans that delivered differing airflows. The maximum plenum airflow velocities ranged from 2.34 to 3.64 m/s (460-716 fpm). Results showed plenum respirable dust concentrations ranging from 34.6% to 49.3% lower than respirable dust concentrations outside the plenum protection zone, thus showing an improvement in protection for the roof bolter operators.