Scatter Correction Requirements for Likelihood-Based Attenuation Artifact Correction in PET

被引:5
作者
Laymon, C. M. [1 ]
Bowsher, J. E. [2 ]
Carney, J. P. J. [1 ]
Blodgett, T. M. [1 ]
机构
[1] Univ Pittsburgh, Pittsburgh, PA 15260 USA
[2] Duke Univ, Durham, NC 27706 USA
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
Positron emission tomography; Xray tomography; Image reconstruction; Attenuation measurement;
D O I
10.1109/NSSMIC.2006.354340
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Artifacts have been observed in CT-based, 511keV attenuation images for PET attenuation correction. Artifact detection and correction algorithms are being developed based on the Poisson loglikelihood function (LLF). The LLF quantifies the level of consistency between an activity and attenuation image pair and the measured emission sinogram. We have shown that the LLF can discriminate more-artifactual from less-artifactual attenuation images at clinical noise levels. Here we use a digital anthropomorphic phantom to examine the effect of scatter on LLF performance. Base sinograms were formed by forward projecting a true activity distribution through a true attenuation distribution. Scatter was simulated by filtering the base sinograms. Noise was considered by producing 128 Poisson-randomized variates of the filtered base sinograms for each of 7 assumed count levels. An artifactual attenuation image was produced by modifying mu-values of regions of the true attenuation image. For each sinogram, two OSEM reconstructions were performed and two LLF values obtained using the artifactual and true attenuation. Accuracy was calculated as the fraction of cases in which the LLF preferred the artifact-free attenuation image. Additional studies were performed to test several scatter correction procedures. Findings show that scatter may render the LLF unreliable even in the limit of high-count scans but that its usefulness is restored by applying an appropriate correction.
引用
收藏
页码:2151 / 2154
页数:4
相关论文
共 50 条
  • [21] Evaluation of simulation-based scatter correction for 3-D PET cardiac imaging
    Watson, CC
    Newport, D
    Casey, ME
    DeKemp, RA
    Beanlands, RS
    Schmand, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (01) : 90 - 97
  • [22] Gamma camera PET with low energy collimators: Characterization and correction of scatter
    Di Bella, EVR
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2067 - 2073
  • [23] Impact of CT-based Attenuation Correction on the Registration Between Dual-gated Cardiac PET and High-Resolution CT
    Turco, A.
    Gheysens, O.
    Nuyts, J.
    Duchenne, J.
    Voigt, J. U.
    Claus, P.
    Vunckx, K.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (01) : 180 - 192
  • [24] An effective scatter correction method based on single scatter simulation for a 3D whole-body PET scanner
    高飞
    Yamada Ryoko
    Watanabe Mitsuo
    刘华锋
    [J]. Chinese Physics B, 2009, 18 (07) : 3066 - 3072
  • [25] An effective scatter correction method based on single scatter simulation for a 3D whole-body PET scanner
    Gao Fei
    Ryoko, Yamada
    Mitsuo, Watanabe
    Liu Hua-Feng
    [J]. CHINESE PHYSICS B, 2009, 18 (07) : 3066 - 3072
  • [26] Bias in PET Images of Solid Phantoms Due to CT-Based Attenuation Correction
    Byrd, Darrin W.
    Sunderland, John J.
    Lee, Tzu-Cheng
    Kinahan, Paul E.
    [J]. TOMOGRAPHY, 2019, 5 (01) : 154 - 160
  • [27] Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
    Hofmann, Matthias
    Pichler, Bernd
    Schoelkopf, Bernhard
    Beyer, Thomas
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : 93 - 104
  • [28] Impact of Different Metal Artifact Reduction Techniques on Attenuation Correction of Normal Organs in 18F-FDG-PET/CT
    Morawitz, Janna
    Martin, Ole
    Boos, Johannes
    Sawicki, Lino M.
    Wingendorf, Katrin
    Sedlmair, Martin
    Mamlins, Eduards
    Antke, Christina
    Antoch, Gerald
    Schaarschmidt, Benedikt M.
    [J]. DIAGNOSTICS, 2022, 12 (02)
  • [29] Revealing Anatomical Structures in PET to Generate CT for Attenuation Correction
    Pan, Yongsheng
    Liu, Feihong
    Jiang, Caiwen
    Huang, Jiawei
    Xia, Yong
    Shen, Dinggang
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT X, 2023, 14229 : 24 - 33
  • [30] ACCURATE ATTENUATION CORRECTION DESPITE MOVEMENT DURING PET IMAGING
    ANDERSSON, JLR
    VAGNHAMMAR, BE
    SCHNEIDER, H
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (04) : 670 - 678