Scatter Correction Requirements for Likelihood-Based Attenuation Artifact Correction in PET

被引:5
|
作者
Laymon, C. M. [1 ]
Bowsher, J. E. [2 ]
Carney, J. P. J. [1 ]
Blodgett, T. M. [1 ]
机构
[1] Univ Pittsburgh, Pittsburgh, PA 15260 USA
[2] Duke Univ, Durham, NC 27706 USA
来源
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6 | 2006年
关键词
Positron emission tomography; Xray tomography; Image reconstruction; Attenuation measurement;
D O I
10.1109/NSSMIC.2006.354340
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Artifacts have been observed in CT-based, 511keV attenuation images for PET attenuation correction. Artifact detection and correction algorithms are being developed based on the Poisson loglikelihood function (LLF). The LLF quantifies the level of consistency between an activity and attenuation image pair and the measured emission sinogram. We have shown that the LLF can discriminate more-artifactual from less-artifactual attenuation images at clinical noise levels. Here we use a digital anthropomorphic phantom to examine the effect of scatter on LLF performance. Base sinograms were formed by forward projecting a true activity distribution through a true attenuation distribution. Scatter was simulated by filtering the base sinograms. Noise was considered by producing 128 Poisson-randomized variates of the filtered base sinograms for each of 7 assumed count levels. An artifactual attenuation image was produced by modifying mu-values of regions of the true attenuation image. For each sinogram, two OSEM reconstructions were performed and two LLF values obtained using the artifactual and true attenuation. Accuracy was calculated as the fraction of cases in which the LLF preferred the artifact-free attenuation image. Additional studies were performed to test several scatter correction procedures. Findings show that scatter may render the LLF unreliable even in the limit of high-count scans but that its usefulness is restored by applying an appropriate correction.
引用
收藏
页码:2151 / 2154
页数:4
相关论文
共 50 条
  • [1] A log likelihood based method for recovery of localized defects in PET attenuation-correction images
    Laymon, CM
    Bowsher, JE
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2710 - 2714
  • [2] Anomaly Detection and Artifact Recovery in PET Attenuation-Correction Images Using the Likelihood Function
    Laymon, Charles M.
    Bowsher, James E.
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2013, 7 (01) : 137 - 146
  • [3] The Effect of Attenuation and Scatter Correction in Rat Brain PET
    Yu, A. Ram
    Kim, Jin Su
    Moon, Jisook
    Kim, Hee Joung
    Lim, Sang Moo
    Kim, Kyeong Min
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 751 - 757
  • [4] Evaluation of Attenuation and Scatter Correction Requirements as a Function of Object Size in Small Animal PET Imaging
    Konik, A.
    Koesters, T.
    Madsen, M. T.
    Sunderland, J. J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2308 - 2314
  • [5] Recovery of localized defects in PET attenuation-correction images
    Laymon, CA
    Bowsher, JE
    Turkington, TG
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1949 - 1952
  • [6] Occurrence of an Artifact in Brain F-18-FDG PET with Calculated Attenuation Correction
    von Borczyskowski, Daniel
    Schulte, Ulrike
    Brenner, Winfried
    Clausen, Malte
    Buchert, Ralph
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2006, 34 (04) : 232 - 234
  • [7] Motion Correction and Attenuation Correction for Respiratory Gated PET Images
    Bai, Wenjia
    Brady, Michael
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 351 - 365
  • [8] Deep Scatter Estimation in PET: Fast Scatter Correction Using a Convolutional Neural Network
    Berker, Yannick
    Maier, Joscha
    Kachelriess, Marc
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [9] Interpolated average CT for cardiac PET/CT attenuation correction
    Mok, Greta S. P.
    Ho, Cobie Y. T.
    Yang, Bang-Hung
    Wu, Tung-Hsin
    JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (05) : 1072 - 1079
  • [10] Attenuation Correction of the Cerebellum in PET/MR Data
    Kops, Elena Rota
    Alrakh, Heba
    Brambilla, Claudia Regio
    Scheins, Jurgen
    Herzog, Hans
    Shah, N. Jon
    Lerche, Christoph
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2024, 8 (06) : 618 - 631