New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: system description and validation

被引:49
作者
Mercier, Laurence [1 ]
Del Maestro, Rolando F. [2 ]
Petrecca, Kevin [2 ]
Kochanowska, Anna [1 ]
Drouin, Simon [1 ]
Yan, Charles X. B. [1 ]
Janke, Andrew L. [3 ]
Chen, Sean Jy-Shyang [1 ]
Collins, D. Louis [1 ]
机构
[1] McGill Univ, Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ, Canada
[2] McGill Univ, Montreal Neurol Hosp & Inst, Brain Tumour Res Ctr, Montreal, PQ, Canada
[3] Australian Natl Univ, Dept Geriatr Med, Canberra, SA, Australia
基金
加拿大健康研究院;
关键词
Application accuracy; Image-guided surgery; Intraoperative imaging; Intraoperative ultrasound; Neuronavigation; Registration; BRAIN-SHIFT; 3-D ULTRASOUND; 3D ULTRASOUND; GUIDED NEUROSURGERY; TUMOR RESECTION; 3-DIMENSIONAL ULTRASOUND; REGISTRATION; CALIBRATION; MRI; ACCURACY;
D O I
10.1007/s11548-010-0535-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose The aim of this report is to present IBIS (Interactive Brain Imaging System) NeuroNav, a new prototype neuronavigation system that has been developed in our research laboratory over the past decade that uses tracked intraoperative ultrasound to address surgical navigation issues related to brain shift. The unique feature of the system is its ability, when needed, to improve the initial patient-to-preoperative image alignment based on the intraoperative ultrasound data. Parts of IBIS Neuronav source code are now publicly available on-line. Methods Four aspects of the system are characterized in this paper: the ultrasound probe calibration, the temporal calibration, the patient-to-image registration and the MRI-ultrasound registration. In order to characterize its real clinical precision and accuracy, the system was tested in a series of adult brain tumor cases. Results Three metrics were computed to evaluate the precision and accuracy of the ultrasound calibration. 1) Reproducibility: 1.77mm and 1.65mm for the bottom corners of the ultrasound image, 2) point reconstruction precision 0.62-0.90mm: and 3) point reconstruction accuracy: 0.49-0.74mm. The temporal calibration error was estimated to be 0.82 ms. The mean fiducial registration error (FRE) of the homologous-point-based patient-to-MRI registration for our clinical data is 4.9 +/- 1.1mm. After the skin landmark-based registration, the mean misalignment between the ultrasound and MR images in the tumor region is 6.1 +/- 3.4 mm. Conclusions The components and functionality of a new prototype system are described and its precision and accuracy evaluated. It was found to have an accuracy similar to other comparable systems in the literature.
引用
收藏
页码:507 / 522
页数:16
相关论文
共 50 条
  • [31] A compact system for intraoperative specimen imaging based on edge illumination x-ray phase contrast
    Havariyoun, Glafkos
    Vittoria, Fabio A.
    Hagen, Charlotte K.
    Basta, Dario
    Kallon, Gibril K.
    Endrizzi, Marco
    Massimi, Lorenzo
    Munro, Peter
    Hawker, Sam
    Smit, Bennie
    Astolfo, Alberto
    Larkin, Oliver J.
    Waltham, Richard M.
    Shah, Zoheb
    Duffy, Stephen W.
    Nelan, Rachel L.
    Peel, Anthony
    Suaris, Tamara
    Jones, J. Louise
    Haig, Ian G.
    Bate, David
    Olivo, Alessandro
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (23)
  • [32] Technique for a hybrid system of real-time transrectal ultrasound with preoperative magnetic resonance imaging in the guidance of targeted prostate biopsy
    Ukimura, Osamu
    Hirahara, Naoki
    Fujihara, Atsuko
    Yamada, Takeshi
    Iwata, Tsuyoshi
    Kamoi, Kazumi
    Okihara, Koji
    Ito, Hirotoshi
    Nishimura, Tsunehiko
    Miki, Tsuneharu
    INTERNATIONAL JOURNAL OF UROLOGY, 2010, 17 (10) : 890 - 893
  • [33] Accuracy of pedicle screw placement based on preoperative computed tomography versus intraoperative data set acquisition for spinal navigation system
    Liu, Hao
    Chen, Weikai
    Liu, Tao
    Meng, Bin
    Yang, Huilin
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (02):
  • [34] Ultrasound-based steatosis grading system using 2D-attenuation imaging: An individual patient data meta-analysis with external validation
    Hobeika, Christian
    Ronot, Maxime
    Guiu, Boris
    Ferraioli, Giovanna
    Iijima, Hiroko
    Tada, Toshifumi
    Lee, Dong Ho
    Kuroda, Hidekatsu
    Lee, Young Hwan
    Lee, Jeong Min
    Kim, So Yeon
    Cassinotto, Christophe
    Maiocchi, Laura
    Raimondi, Ambra
    Nishimura, Takashi
    Kumada, Takashi
    Kwon, Eun Young
    Jang, Jong Keon
    Correas, Jean-Michel
    Valla, Dominique
    Vilgrain, Valerie
    Burgio, Marco Dioguardi
    HEPATOLOGY, 2025, 81 (01) : 212 - 227
  • [35] Image quality and dose characteristics for an O-arm intraoperative imaging system with model-based image reconstruction
    Uneri, A.
    Zhang, X.
    Yi, T.
    Stayman, J. W.
    Helm, P. A.
    Theodore, N.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2018, 45 (11) : 4857 - 4868
  • [36] Radiation dose reduction in thoracic and lumbar spine instrumentation using navigation based on an intraoperative cone beam CT imaging system: a prospective randomized clinical trial
    Pireau, Nathalie
    Cordemans, Virginie
    Banse, Xavier
    Irda, Nadia
    Lichtherte, Sbastien
    Kaminski, Ludovic
    EUROPEAN SPINE JOURNAL, 2017, 26 (11) : 2818 - 2827
  • [37] Contrast-enhanced ultrasound liver imaging reporting and data system: clinical validation in a prospective multinational study in North America and Europe
    Lyshchik, Andrej
    Wessner, Corinne E.
    Bradigan, Kristen
    Eisenbrey, John R.
    Forsberg, Flemming
    Yi, Misung
    Keith, Scott W.
    Kono, Yuko
    Wilson, Stephanie R.
    Medellin, Alexandra
    Rodgers, Shuchi K.
    Planz, Virginia
    Kamaya, Aya
    Finch, Lisa
    Fetzer, David T.
    Berzigotti, Annalisa
    Sidhu, Paul S.
    Piscaglia, Fabio
    HEPATOLOGY, 2024, 79 (02) : 380 - 391
  • [38] New Grading System Based on Magnetic Resonance Imaging in a Mouse Model of Subarachnoid Hemorrhage
    Egashira, Yusuke
    Shishido, Hajime
    Hua, Ya
    Keep, Richard F.
    Xi, Guohua
    STROKE, 2015, 46 (02) : 582 - 584
  • [39] Tumor size-based validation of contrast-enhanced ultrasound liver imaging reporting and data system (CEUS LI-RADS) 2017 for hepatocellular carcinoma characterizing
    Pan, Jia-Min
    Chen, Wei
    Zheng, Yan-Ling
    Cheng, Mei-Qing
    Zeng, Dan
    Huang, Hui
    Huang, Yang
    Xie, Xiao-Yan
    Lu, Ming-De
    Kuang, Ming
    Hu, Hang-Tong
    Chen, Li-Da
    Wang, Wei
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1126)
  • [40] First ground-based, high-field, cryogen-free, mobile intraoperative magnetic resonance imaging system
    Lang, Michael L.
    Zhang, Qiang
    Chen, Xiaolei
    Yan, Niandong
    Zhu, Haoqin
    Martin, Melanie
    Yu, Feng
    Niu, Chaoshi
    Zhang, Gong
    Zeng, Qiang
    MAGNETIC RESONANCE IMAGING, 2023, 99 : 1 - 7