Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography

被引:69
作者
Han, Hyonyoung [1 ]
Kim, Min-Joon [2 ]
Kim, Jung [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Mech Engn, Taejon 305701, South Korea
[2] H3 Syst, Daejeon, South Korea
来源
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16 | 2007年
关键词
D O I
10.1109/IEMBS.2007.4352596
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a motion artifact reduction algorithm for a real-time, wireless and wearable photoplethysmography (PPG) device for measuring heart beats. A wearable finger band PPG device consists of a 3-axis accelerometer, infrared LED, photo diode, a microprocessor and wireless module. Sources of the motion artifacts were investigated from the hand motions, through computing the correlations between the three directional finger motions and distorted PPG signals. A two-dimensional active noise cancellation algorithm was applied to compensate the distorted signals by motions, using the directional accelerometer data. NLMS (Normalized Least Mean Square) adaptive filter (4th order) was employed in the algorithm. As a result, the signals' distortion rates were reduced from 52.34% to 3.53%, at frequencies between 1 and 2.5 Hz, which representing daily motions such walking and jogging. The wearable health monitoring device equipped with the motion artifact reduction algorithm can be integrated as a terminal in a so-called ubiquitous healthcare system, which provides a continuous health monitoring without interrupting a daily life.
引用
收藏
页码:1538 / +
页数:2
相关论文
共 10 条
[1]  
Asada HH, 2004, P ANN INT IEEE EMBS, V26, P2157
[2]   Mobile monitoring with wearable photoplethysmographic biosensors [J].
Asada, HH ;
Shaltis, P ;
Reisner, A ;
Rhee, S ;
Hutchinson, RC .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2003, 22 (03) :28-40
[3]  
CHAN KW, 2002, ADAPTIVE REDUCTION M
[4]   Motion artifact reduction in photoplethysmography using independent component analysis [J].
Kim, BS ;
Yoo, SK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) :566-568
[5]  
KUNESCH E, 1989, EXP BRAIN RES, V78, P539
[6]  
Kuo Sen M., 1996, ACTIVE NOISE CONTROL
[7]  
RENEVEY RVP, 2001, 23 ANN EMBS INT C IS
[8]  
Webster J. G., 1997, DESIGN PULSE OXIMETE
[9]   Hand motion gesture frequency properties and multimodal discourse analysis [J].
Xiong, Yingen ;
Quek, Francis .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2006, 69 (03) :353-371
[10]   Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution [J].
Yan Y.-S. ;
Poon C.C.Y. ;
Zhang Y.-T. .
Journal of NeuroEngineering and Rehabilitation, 2 (1)