Preparation and evaluation of a bacitracin-bonded silica stationary phase for hydrophilic interaction liquid chromatography

被引:8
|
作者
Zhang, Zuoling [1 ]
Xia, Min [1 ]
Huang, Pengfei [1 ]
Di, Bin [1 ,2 ,3 ]
Su, Mengxiang [1 ,2 ,3 ]
机构
[1] China Pharmaceut Univ, Dept Pharmaceut Anal, 24 Tongjiaxiang Rd, Nanjing 210009, Peoples R China
[2] Minist Educ, Key Lab Drug Qual Control & Pharmacovigilance, Nanjing 210009, Peoples R China
[3] NMPA Key Lab Res & Evaluat Pharmaceut Preparat &, Nanjing 210009, Peoples R China
基金
中国国家自然科学基金;
关键词
Bacitracin; Silica particles; Stationary phase; Polar analytes; HILIC; SEPARATION; PEPTIDES; ACIDS; RETENTION; COLUMN;
D O I
10.1016/j.microc.2021.106661
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New stationary-phase materials are of great interest for use in hydrophilic interaction liquid chromatography (HILIC), a relatively new technique capable of separating highly polar compounds. In this study, a new strategy was established to prepare a novel Sil-Bac stationary phase by bonding bacitracin to silanised silica particles using hexamethylene diisocyanate as a spacer arm. The obtained material was characterised by Fourier transform infrared spectroscopy, Brunauer-Emmett-Teller analysis, transmission electron microscopy (TEM), and elemental analysis. The network layers observed through TEM and change in specific surface area from 315.0820 to 169.6758 m(2).g(-1) after modification reflected the addition of bacitracin. The chromatographic behaviour of the Sil-Bac column showed that it can be used for HILIC. The influence of the chromatographic conditions on substance retention was explored by varying the acetonitrile content, column temperature, buffer concentration, and pH of the mobile phase. Using cytosine, uracil, nicotinamide, and isonicotinic acid as probes, the Sil-Bac column was demonstrated to have acceptable repeatability and stability, with a relative standard deviation of the retention time in the ranges of 0.05-0.18% for intra-day precision (n = 3) and 0.16-3.28% for inter-day precision (n = 3). Finally, the stationary phase was applied in separating basic nucleosides, water-soluble vitamins, and amino acids. A variety of bases and nucleosides could be separated within 7 min in a mobile phase of ACN/ammonium acetate (pH 3.0) = 90/10 (v/v), T = 30 degrees C. The Sil-Bac column was also compared with three commercial columns, and the results indicated that the analytes retained on the Sil-Bac column showed better retention and selectivity from an overall view. This novel stationary phase has a good separation ability and selectivity in HILIC mode and provides new ideas for the separation of polar compounds.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Preparation, Characterization and Evaluation of Magnolol-bonded Silica Gel Stationary Phase for Reversed-phase Liquid Chromatography
    Li Lai-Sheng
    Chen Hong
    Ma Hai-Ping
    Fang Yi-Shan
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2012, 33 (04): : 707 - 713
  • [22] Dipeptide-bonded stationary phases for hydrophilic interaction liquid chromatography
    Skoczylas, Magdalena
    Bocian, Szymon
    Buszewski, Boguslaw
    RSC ADVANCES, 2016, 6 (98): : 96389 - 96397
  • [23] A new nano-on-micro stationary phase based on nanodiamond bonded on silica for hydrophilic interaction chromatography
    Cai, Tianpei
    Zhang, Haijuan
    Li, Zhan
    Rahman, A. F. M. Mustafizur
    Qiu, Hongdeng
    RSC ADVANCES, 2016, 6 (39): : 32757 - 32760
  • [24] Preparation of xylitol and maltitol modified silica as novel stationary phases for hydrophilic interaction liquid chromatography and evaluation of their separation performance
    Yong Tian
    Wu Fan
    Xiao Hongbin
    Wan Boshun
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2015, 33 (09) : 910 - 916
  • [25] Covalently bonded polysaccharide-modified stationary phase for per aqueous liquid chromatography and hydrophilic interaction chromatography
    Li, Yuanyuan
    Li, Jiao
    Chen, Tong
    Liu, Xiaoyan
    Zhang, Haixia
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (11) : 1503 - 1508
  • [26] Preparation of pH-responsive stationary phase for reversed-phase liquid chromatography and hydrophilic interaction chromatography
    Ma, Qiao
    Chen, Ming
    Yin, Hong-Rui
    Shi, Zhi-Guo
    Feng, Yu-Qi
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1212 (1-2) : 61 - 67
  • [27] Low-Bleed Silica-Based Stationary Phase for Hydrophilic Interaction Liquid Chromatography
    Qian, Kun
    Yang, Zhanqiang
    Zhang, Feifang
    Yang, Bingcheng
    Dasgupta, Purnendu K.
    ANALYTICAL CHEMISTRY, 2018, 90 (15) : 8750 - 8755
  • [28] Chromatographic evaluation of a newly designed peptide-silica stationary phase in reverse phase liquid chromatography and hydrophilic interaction liquid chromatography: Mixed mode behavior
    Ray, Sudipta
    Takafuji, Makoto
    Ihara, Hirotaka
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1266 : 43 - 52
  • [29] Preparation and chromatographic evaluation of the hydrophilic interaction chromatography stationary phase based on nucleosides or nucleotides
    Tang, Tingfeng
    Guo, Dandan
    Huang, Shaohua
    ANALYTICAL METHODS, 2021, 13 (03) : 419 - 425
  • [30] Tetra-proline modified calix[4]arene bonded silica gel: A novel stationary phase for hydrophilic interaction liquid chromatography
    Zhang, Wenfen
    Zhang, Yanhao
    Zhang, Yongming
    Lan, Chen
    Miao, Ying
    Deng, Zhifen
    Ba, Xin
    Zhao, Wuduo
    Zhang, Shusheng
    TALANTA, 2019, 193 : 56 - 63