Monte Carlo simulation code for confocal 3D micro-beam X-ray fluorescence analysis of stratifiedmaterials

被引:25
|
作者
Czyzycki, Mateusz [1 ]
Wegrzynek, Dariusz [1 ]
Wrobel, Pawel [1 ]
Lankosz, Andmarek [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Phys & Appl Comp Sci, PL-30059 Krakow, Poland
关键词
TRACE-ELEMENT ANALYSIS; COMET; 81P/WILD-2; PAINT LAYERS; MU-XRF; MICROFLUORESCENCE; SPECTROSCOPY; PARTICLES; OPTICS;
D O I
10.1002/xrs.1300
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Stratified materials are of great importance for many branches of modern industry, e. g. electronics or optics and for biomedical applications. Examination of chemical composition of individual layers and determination of their thickness helps to get information on their properties and function. A confocal 3D micro X-ray fluorescence (3D mu XRF) spectroscopy is an analytical method giving the possibility to investigate 3D distribution of chemical elements in a sample with spatial resolution in the micrometer regime in a non-destructive way. Thin foils of Ti, Cu and Au, a bulk sample of Cu and a three-layered sandwich sample, made of two thin Fe/Ni alloy foils, separated by polypropylene, were used as test samples. A Monte Carlo (MC) simulation code for the determination of elemental concentrations and thickness of individual layers in stratified materials with the use of confocal 3D mu XRF spectroscopy was developed. The X-ray intensity profiles versus the depth below surface, obtained from 3D mu XRF experiments, MC simulation and an analytical approach were compared. Correlation coefficients between experimental versus simulated, and experimental versus analytical model X-ray profiles were calculated. The correlation coefficients were comparable for both methods and exceeded 99%. The experimental X-ray intensity profiles were deconvoluted with iterative MC simulation and by using analytical expression. The MC method produced slightly more accurate elemental concentrations and thickness of successive layers as compared to the results of the analytical approach. This MC code is a robust tool for simulation of scanning confocal 3D mu XRF experiments on stratified materials and for quantitative interpretation of experimental results. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:88 / 95
页数:8
相关论文
共 50 条
  • [21] Development of a new confocal 3D-XRF instrument with an X-ray tube
    Tsuji, Kouichi
    Nakano, Kazuhiko
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (02) : 305 - 309
  • [22] Size-Resolved Source Apportionment of Aerosol Particles with a Confocal Micro X-Ray Fluorescence Spectrometer
    Sun, Tianxi
    Liu, Zhiguo
    Li, Yude
    Ma, Yongzhong
    Wang, Guangfu
    Zhu, Guanghua
    Xu, Qing
    Lin, Xiaoyan
    Luo, Ping
    Pan, Qiuli
    Liu, Hui
    Teng, Yuepeng
    Ding, Xunliang
    APPLIED SPECTROSCOPY, 2011, 65 (12) : 1398 - 1402
  • [23] Gold Nanoparticles at the Liquid-Liquid Interface: X-ray Study and Monte Carlo Simulation
    Kubowicz, Stephan
    Hartmann, Markus A.
    Daillant, Jean
    Sanyal, Milan K.
    Agrawal, Ved V.
    Blot, Christian
    Konovalov, Oleg
    Moehwald, Helmuth
    LANGMUIR, 2009, 25 (02) : 952 - 958
  • [24] A multiplatform code for the analysis of energy-dispersive X-ray fluorescence spectra
    Sole, V. A.
    Papillon, E.
    Cotte, M.
    Walter, Ph.
    Susini, J.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (01) : 63 - 68
  • [25] A deep view in cultural heritage-confocal micro X-ray spectroscopy for depth resolved elemental analysis
    Kanngiesser, B.
    Malzer, W.
    Mantouvalou, I.
    Sokaras, D.
    Karydas, A. G.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2012, 106 (02): : 325 - 338
  • [26] A new micro X-ray fluorescence spectrometer for in vivo elemental analysis in plants
    Fittschen, U. E. A.
    Kunz, H. -H.
    Hohner, R.
    Tyssebotn, I. M. B.
    Fittschen, A.
    X-RAY SPECTROMETRY, 2017, 46 (05) : 374 - 381
  • [27] Elemental depth imaging of solutions for monitoring corrosion process of steel sheet by confocal micro X-ray fluorescence
    Hirano, S.
    Akioka, K.
    Doi, T.
    Arai, M.
    Tsuji, K.
    X-RAY SPECTROMETRY, 2014, 43 (04) : 216 - 220
  • [28] Chemical U-Th-Pb dating of monazite by 3D-Micro X-ray fluorescence analysis with synchrotron radiation
    Schmitz, Sylvia
    Moeller, Andreas
    Wilke, Max
    Malzer, Wolfgang
    Kanngiesser, Birgit
    Bousquet, Romain
    Berger, Alfons
    Schefer, Senecio
    EUROPEAN JOURNAL OF MINERALOGY, 2009, 21 (05) : 927 - 945
  • [29] Characterization of the new mobile confocal micro X-ray fluorescence (CXRF) system for in situ non-destructive cultural heritage analysis at the CNA: μXRF-CONCHA
    Laclavetine, Kilian
    Ager, Francisco J.
    Arquillo, Joaquin
    Angel Respaldiza, Miguel
    Scrivano, Simona
    MICROCHEMICAL JOURNAL, 2016, 125 : 62 - 68
  • [30] 3D analysis of TRISO fuel compacts via X-ray computed tomography
    Kane, Joshua J.
    Marshall, Douglas W.
    Cordes, Nikolaus L.
    Chuirazzi, William C.
    Kombaiah, Boopathy
    van Rooyen, Isabella
    Stempien, John D.
    JOURNAL OF NUCLEAR MATERIALS, 2022, 565