摘要
Background Interrupted aortic arch (IAA) is a rare but severe congenital abnormality often associated with bicuspid aortic valve (BAV). Complex re-interventions are often needed despite surgical advances, but the impact of aortic hemodynamics in repaired patients is unknown. Objective Investigate effect of IAA repairs on aortic hemodynamics, wall shear stress and flow derangements via 4-D flow MRI. Materials and methods We retrospectively analyzed age- and gender-matched cohorts (IAA [n=6], BAV alone [n=6], controls [n=6]) undergoing cardiac MRI including 4-D flow. Aortic dimensions were measured from standard MR angiography. We quantified peak systolic velocities, regurgitant fractions and wall shear stress in the ascending aorta (AAo), transverse arch and descending aorta (DAo) from 4-D flow, and we graded helix/vortex flow patterns from 3-D blood flow visualization. Results Children and young adults with IAA had a wide range of arch dimensions, peak systolic velocities, regurgitant fractions and flow grades. Peak transverse arch systolic velocities were higher in patients with IAA versus controls (P=0.02). Flow derangements in the AAo were found in patients with IAA (median grade=2, 5/6 patients, P=0.04) and BAV (median grade=3, 5/6 patients, P=0.03) versus controls. Flow derangements in the DAo were only seen in patients with IAA (median grade=1, 5/6 patients, P=0.04), and 5/6 people with IAA had helical flow in head and neck vessels. Wall shear stress was increased in people with IAA along the superior transverse arch and proximal DAo versus controls (P=0.02). Conclusion Complex congenital aortic arch repairs can change aortic hemodynamics. Associated cardiac defects can further alter findings. Studies are warranted to investigate clinical implications in larger cohorts.
引用
收藏
页码:17 / 27
页数:11
相关论文
共 50 条
  • [31] Novel Insights into Complex Cardiovascular Pathologies using 4D Flow Analysis by Cardiovascular Magnetic Resonance Imaging
    Lewandowski, Adam James
    Raman, Betty
    Banerjee, Rajarshi
    Milanesi, Matteo
    CURRENT PHARMACEUTICAL DESIGN, 2017, 23 (22) : 3262 - 3267
  • [32] Additional value and new insights by four-dimensional flow magnetic resonance imaging in congenital heart disease: application in neonates and young children
    Geiger, Julia
    Callaghan, Fraser M.
    Burkhardt, Barbara E. U.
    Buechel, Emanuela R. Valsangiacomo
    Kellenberger, Christian J.
    PEDIATRIC RADIOLOGY, 2021, 51 (08) : 1503 - 1517
  • [33] Additional value and new insights by four-dimensional flow magnetic resonance imaging in congenital heart disease: application in neonates and young children
    Julia Geiger
    Fraser M. Callaghan
    Barbara E. U. Burkhardt
    Emanuela R. Valsangiacomo Buechel
    Christian J. Kellenberger
    Pediatric Radiology, 2021, 51 : 1503 - 1517
  • [34] Intracranial 4D flow magnetic resonance imaging reveals altered haemodynamics in sickle cell disease
    Vaclavu, Lena
    Baldew, Zelonna A. V.
    Gevers, Sanna
    Mutsaerts, Henri J. M. M.
    Fijnvandraat, Karin
    Cnossen, Marjon H.
    Majoie, Charles B.
    Wood, John C.
    VanBavel, Ed
    Biemond, Bart J.
    van Ooij, Pim
    Nederveen, Aart J.
    BRITISH JOURNAL OF HAEMATOLOGY, 2018, 180 (03) : 432 - 442
  • [35] Blood flow characteristics in the ascending aorta after aortic valve replacement-a pilot study using 4D-flow MRI
    von Knobelsdorff-Brenkenhoff, Florian
    Trauzeddel, Ralf F.
    Barker, Alex J.
    Gruettner, Henriette
    Markl, Michael
    Schulz-Menger, Jeanette
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 170 (03) : 426 - 433
  • [36] Magnetic resonance imaging of complex congenital heart disease
    Yoo, SJ
    Kim, YM
    Choe, YH
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1999, 15 (02): : 151 - 160
  • [37] Blood flow measurement by magnetic resonance imaging in congenital heart disease
    Powell, AJ
    Geva, T
    PEDIATRIC CARDIOLOGY, 2000, 21 (01) : 47 - 58
  • [38] Magnetic resonance imaging of complex congenital heart disease
    Shi-Joon Yoo
    Yang Min Kim
    Yeon Hyeon Choe
    The International Journal of Cardiac Imaging, 1999, 15 : 151 - 160
  • [39] Congenital aortic disease: 4D magnetic resonance segmentation and quantitative analysis
    Zhao, Fei
    Zhang, Honghai
    Wahle, Andreas
    Thomas, Matthew T.
    Stolpen, Alan H.
    Scholz, Thomas D.
    Sonka, Milan
    MEDICAL IMAGE ANALYSIS, 2009, 13 (03) : 483 - 493
  • [40] 4-D flow MRI aortic 3-D hemodynamics and wall shear stress remain stable over short-term follow-up in pediatric and young adult patients with bicuspid aortic valve
    Michael J. Rose
    Cynthia K. Rigsby
    Haben Berhane
    Emilie Bollache
    Kelly Jarvis
    Alex J. Barker
    Susanne Schnell
    Bradley D. Allen
    Joshua D. Robinson
    Michael Markl
    Pediatric Radiology, 2019, 49 : 57 - 67