Altered 4-D magnetic resonance imaging flow characteristics in complex congenital aortic arch repair

被引:3
|
作者
Desai, Lajja P. [1 ,2 ]
Berhane, Haben [1 ]
Husain, Nazia [1 ,2 ]
Robinson, Joshua D. [1 ,2 ]
Rigsby, Cynthia K. [1 ,2 ]
Markl, Michael [2 ]
机构
[1] Ann & Robert H Lurie Childrens Hosp Chicago, 225 E Chicago Ave, Chicago, IL 60611 USA
[2] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
Aorta; Children; Congenital heart disease; Four-dimensional flow; Heart; Interrupted aortic arch; Magnetic resonance imaging; VENTRICULAR SEPTAL-DEFECT; WALL SHEAR-STRESS; INTRACRANIAL ANEURYSMS; OUTCOMES; VALVE; MORPHOLOGY; PATTERNS; HEMODYNAMICS; COARCTATION; MORTALITY;
D O I
10.1007/s00247-019-04507-0
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background Interrupted aortic arch (IAA) is a rare but severe congenital abnormality often associated with bicuspid aortic valve (BAV). Complex re-interventions are often needed despite surgical advances, but the impact of aortic hemodynamics in repaired patients is unknown. Objective Investigate effect of IAA repairs on aortic hemodynamics, wall shear stress and flow derangements via 4-D flow MRI. Materials and methods We retrospectively analyzed age- and gender-matched cohorts (IAA [n=6], BAV alone [n=6], controls [n=6]) undergoing cardiac MRI including 4-D flow. Aortic dimensions were measured from standard MR angiography. We quantified peak systolic velocities, regurgitant fractions and wall shear stress in the ascending aorta (AAo), transverse arch and descending aorta (DAo) from 4-D flow, and we graded helix/vortex flow patterns from 3-D blood flow visualization. Results Children and young adults with IAA had a wide range of arch dimensions, peak systolic velocities, regurgitant fractions and flow grades. Peak transverse arch systolic velocities were higher in patients with IAA versus controls (P=0.02). Flow derangements in the AAo were found in patients with IAA (median grade=2, 5/6 patients, P=0.04) and BAV (median grade=3, 5/6 patients, P=0.03) versus controls. Flow derangements in the DAo were only seen in patients with IAA (median grade=1, 5/6 patients, P=0.04), and 5/6 people with IAA had helical flow in head and neck vessels. Wall shear stress was increased in people with IAA along the superior transverse arch and proximal DAo versus controls (P=0.02). Conclusion Complex congenital aortic arch repairs can change aortic hemodynamics. Associated cardiac defects can further alter findings. Studies are warranted to investigate clinical implications in larger cohorts.
引用
收藏
页码:17 / 27
页数:11
相关论文
共 50 条
  • [21] Importance of complex blood flow in the assessment of aortic regurgitation severity using phase contrast magnetic resonance imaging
    Truedsson, Frida
    Polte, Christian L.
    Gao, Sinsia A.
    Johnsson, Ase A.
    Bech-Hanssen, Odd
    Lagerstrand, Kerstin M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (12) : 3561 - 3572
  • [22] Blood flow measured by magnetic resonance imaging at rest and exercise after surgical bypass of aortic arch obstruction
    Pedersen, Lia Mendes
    Pedersen, Thais Almeida Lins
    Pedersen, Erik Morre
    Hojmyr, Hilde
    Emmertsen, Kristian
    Hjortdal, Vibeke Etisabeth
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 37 (03) : 658 - 661
  • [23] Double aortic arch in D-transposition of the great arteries - Confirmation of dominant arch by magnetic resonance imaging
    McMahon, CJ
    Bezold, LI
    Vick, GW
    TEXAS HEART INSTITUTE JOURNAL, 2000, 27 (04) : 398 - 400
  • [24] Clinical Applications of Aortic 4D Flow Imaging
    Hope M.D.
    Wrenn S.J.
    Dyverfeldt P.
    Current Cardiovascular Imaging Reports, 2013, 6 (2) : 128 - 139
  • [25] Traveling Volunteers: A Multi-Vendor, Multi-Center Study on Reproducibility and Comparability of 4D Flow Derived Aortic Hemodynamics in Cardiovascular Magnetic Resonance
    Demir, Aylin
    Wiesemann, Stephanie
    Erley, Jennifer
    Schmitter, Sebastian
    Trauzeddel, Ralf Felix
    Pieske, Burkert
    Hansmann, Jochen
    Kelle, Sebastian
    Schulz-Menger, Jeanette
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 211 - 222
  • [26] Altered left ventricular vortex ring formation by 4-dimensional flow magnetic resonance imaging after repair of atrioventricular septal defects
    Calkoen, Emmeline E.
    Elbaz, Mohammed S. M.
    Westenberg, Jos J. M.
    Kroft, Lucia J. M.
    Hazekamp, Mark G.
    Roest, Arno A. W.
    van der Geest, Rob J.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (05) : 1233 - +
  • [27] Changes of Brain Magnetic Resonance Imaging Findings After Congenital Aortic Arch Anomaly Repair Using Regional Cerebral Perfusion in Neonates and Young Infants
    Kwak, Jae Gun
    Kim, Woong-Han
    Kim, Jin Tae
    Kim, In-One
    Chae, Jong-Hee
    ANNALS OF THORACIC SURGERY, 2010, 90 (06) : 1996 - 2000
  • [28] Interdependencies of aortic arch secondary flow patterns, geometry, and age analysed by 4-dimensional phase contrast magnetic resonance imaging at 3 Tesla
    Frydrychowicz, Alex
    Berger, Alexander
    del Rio, Alejandro Munoz
    Russe, Maximilian F.
    Bock, Jelena
    Harloff, Andreas
    Markl, Michael
    EUROPEAN RADIOLOGY, 2012, 22 (05) : 1122 - 1130
  • [29] Cardiac magnetic resonance imaging in a premature baby with interrupted aortic arch and aortopulmonary window
    Tzifa, Aphrodite
    Komnou, Areti
    Loggitsi, Dimitra
    CARDIOLOGY IN THE YOUNG, 2013, 23 (05) : 742 - 745
  • [30] Aortopulmonary window with interrupted aortic arch and pulmonary artery sling: Diagnosis by echocardiography and magnetic resonance imaging: Case report and literature review
    Teo, ELHJ
    Goldberg, CS
    Strouse, PJ
    Vermilion, RP
    Bove, EL
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1999, 16 (02): : 147 - 150