Interobserver and Intraobserver Reliabilities of Three-Dimensional Postoperative Evaluation Software in Total Hip Arthroplasty

被引:1
作者
Konno, Kenta [1 ]
Hagiwara, Shigeo [1 ]
Nakamura, Junichi [1 ]
Kawarai, Yuya [1 ]
Orita, Sumihisa [1 ]
Eguchi, Yawara [1 ]
Ohtori, Seiji [1 ]
机构
[1] Chiba Univ, Grad Sch Med, Dept Orthopaed Surg, Chuo Ku, 1-8-1 Inohana, Chiba 2608670, Japan
关键词
ACETABULAR COMPONENT ORIENTATION; LEG-LENGTH; STEM; REPLACEMENT; DISLOCATION; SYSTEM; CUP; ANTEVERSION; ACCURACY; MOTION;
D O I
10.1155/2021/3705789
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. In primary and revision total hip arthroplasty, to prevent perioperative complications, the prediction of the optimal implant size is essential. Using three-dimensional computed tomography-based postoperative evaluation software, we explored the accuracy and the precision of measurement of the size, alignment, and position of the prosthetic components after total hip arthroplasty. Methods. Using postoperative evaluation software, the postoperative computed tomography data from 20 hips in 20 patients were evaluated. The component size, alignment, and three-dimensional positioning of the cup and stem were assessed. The concordance rates of the component, repeatability (intraobserver reliability), and reproducibility (interobserver reliability) of postoperative evaluation were calculated. The radiographic inclination and radiographic anteversion of the cup, anteversion, varus-valgus angle, and flexion-extension angles of the stem were measured for alignment. The implant positioning was measured along three axes, namely, X-axis (transverse), Y-axis (sagittal), and Z-axis (longitudinal). Results. The concordance rates of all parts are above 94%. The intraobserver and interobserver intraclass correlation coefficients of alignment measurement were very good for both cup (0.879-0.964) and stem (0.973-0.996). The intraobserver and interobserver intraclass correlation coefficients of cup positioning were very good (0.961-0.987) for all axes. The intraobserver and interobserver intraclass correlation coefficients of implant positioning were very good for the stem (0.879-0.995) for all axes. Conclusions. Computed tomography-based postoperative evaluation software was able to evaluate the size and position of total hip implants with high reproducibility.
引用
收藏
页数:9
相关论文
共 35 条
[1]  
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[2]   The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[3]  
Delp SL, 1996, CLIN ORTHOP RELAT R, P137
[4]   Inter-Rater and Intra-Rater Repeatability and Reliability of EOS 3-Dimensional Imaging Analysis Software [J].
Demzik, Alysen L. ;
Alvi, Hasham M. ;
Delagrammaticas, Dimitri E. ;
Martell, John M. ;
Beal, Matthew D. ;
Manning, David W. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (05) :1091-1095
[5]   A Comparison of Surgeon Estimation and Computed Tomographic Measurement of Femoral Component Anteversion in Cementless Total Hip Arthroplasty [J].
Dorr, Lawrence D. ;
Wan, Zhinian ;
Malik, Aamer ;
Zhu, Jinjun ;
Dastane, Manish ;
Deshmane, Prashant .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (11) :2598-2604
[6]   POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[7]   Reliability of a New Method for Evaluating Femoral Stem Positioning After Total Hip Arthroplasty Based on Stereoradiographic 3D Reconstruction [J].
Guenoun, Benjamin ;
El Hajj, Firass ;
Biau, David ;
Anract, Philippe ;
Courpied, Jean-Pierre .
JOURNAL OF ARTHROPLASTY, 2015, 30 (01) :141-144
[8]  
Huddleston HD, 1997, ORTHOPEDICS, V20, P331
[9]   Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement [J].
Kalteis, T ;
Handel, M ;
Herold, T ;
Perlick, L ;
Paetzel, C ;
Grifka, J .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 58 (02) :294-300
[10]   Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration [J].
Kennedy, JG ;
Rogers, WB ;
Soffe, KE ;
Sullivan, RJ ;
Griffen, DG ;
Sheehan, LJ .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :530-534