摘要
Phase-shifting transformers (PSTs) provide an economical solution to control the power flow in the electric grids. However, the PSTs vitiate the conventional protection system applied. This paper studies the impact of the delta-hexagonal phase-shifting transformer on the performance of the distance protection relays for the transmission lines. Modified distance protection formulas are derived for both phase and ground faults. The proposed method uses the local measurements at the relay point and does not require voltage or current measurements from a remote substation. Alternatively, the tap position of the phase-shifting transformer is the data needs to be shared between substations which can be accomplished using a simple communication method. The proposed method is evaluated on a simulated transmission line using MATLAB/Simulink packages. The results show the ability of the proposed method to compensate for the PST effect on the distance protection relays.
引用
收藏
页数:8
相关论文
共 29 条
[1]   A faulted side identification scheme-based integrated distance protection for series-compensated transmission lines [J].
Abd el-Ghany, Hossam A. ;
Elsadd, Mahmoud A. ;
Ahmed, Eman S. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 113 :664-673
[2]   Realistic insights into impedance seen by distance relays of a SSSC-compensated transmission line incorporating shunt capacitance of line [J].
Abdollahzadeh, Hamed ;
Mozafari, Babak ;
Jazaeri, Mostafa .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 65 :394-407
[3]   Compensation of the Current-Transformer Saturation Effects for Digital Relays [J].
Ajaei, Firouz Badrkhani ;
Sanaye-Pasand, Majid ;
Davarpanah, Mahdi ;
Rezaei-Zare, Afshin ;
Iravani, Reza .
IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) :2531-2540
[4]  
Albasri FA, 2006, 2006 POWER SYSTEMS CONFERENCE ADVANCED METERING, PROTECTION, CONTROL, COMMUNICATION, AND DISTRIBUTED RESOURCES, P247
[5]   Multiobjective generation and transmission expansion planning of renewable dominated power systems using stochastic normalized normal constraint [J].
Arasteh, Hamidreza ;
Kia, Mohsen ;
Vahidinasab, Vahid ;
Shafie-khah, Miadreza ;
Catalao, Joao P. S. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 121
[6]  
Calero F, 2009, P 36 ANN W PROT REL, P1
[7]   Distance protection of shunt compensated transmission line using a sparse S-transform [J].
Dash, Pradipta Kishore ;
Das, Sahasransu ;
Moirangthem, Joymala .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (12) :1264-1274
[8]   Adaptive distance protection scheme for shunt-FACTS compensated line connecting wind farm [J].
Dubey, Rahul ;
Samantaray, Subhransu Ranjan ;
Panigrahi, Bijay Ketan .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (01) :247-256
[9]   Simultaneous impact of unified power flow controller and off-shore wind penetration on distance relay characteristics [J].
Dubey, Rahul ;
Samantaray, Subhransu Ranjan ;
Panigrahi, Bijay Ketan .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (11) :1869-1880
[10]   Ground distance relay compensation in the presence of delta-hexagonal phase shifting transformer [J].
Ghorbani, Amir ;
Arablu, Masoud .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (15) :2091-2098