High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates

被引:49
|
作者
Goetti, Robert [2 ]
Feuchtner, Gudrun [2 ]
Stolzmann, Paul [2 ,3 ]
Desbiolles, Lotus [2 ]
Fischer, Michael Alexander [2 ]
Karlo, Christoph [2 ]
Baumueller, Stephan [2 ]
Scheffel, Hans [2 ,3 ]
Alkadhi, Hatem [2 ,3 ]
Leschka, Sebastian [1 ,2 ]
机构
[1] Kantonsspital, Inst Radiol, CH-9007 St Gallen, Switzerland
[2] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[3] Massachusetts Gen Hosp, Cardiac MR PET CT Program, Boston, MA 02114 USA
关键词
High-pitch; Computed tomography; Systolic reconstruction; Coronary arteries; Heart rate; Radiation dose; SOURCE COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; RADIATION-EXPOSURE; IMAGE QUALITY; ROW CT; WINDOWS; AORTA;
D O I
10.1007/s00330-010-1838-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess the effect of systolic data acquisition for electrocardiography (ECG)-triggered high-pitch computed tomography (CT) on motion artefacts of coronary arteries in patients with high heart rates (HRs). Eighty consecutive patients (15 women, age 67 +/- 14 years) with HR a parts per thousand yen70 bpm underwent CT angiography of the thoracic aorta (CTA) on 128-slice dual-source CT in ECG-triggered high-pitch acquisition mode (pitch = 3.2) set at 60% (group A, n = 40) or 30% (group B, n = 40) of the RR interval. Two blinded readers graded coronary artery image quality on a three-point scale. Radiation doses were calculated. Inter-observer agreement in grading image quality of the 1,154 coronary segments was good (kappa = 0.62). HRs were similar in groups A and B (85 +/- 13 bpm vs 85 +/- 14 bpm, p not significant). Significantly fewer coronary segments with non-diagnostic image quality occurred (i.e. score 3) in group B than in group A [2.8% (16/579) vs 8.3% (48/575), p < 0.001]. Seventeen patients (42.5%) of group A and 12 patients (30.0%) of group B had at least one non-diagnostic segment. Effective radiation doses were 2.3 +/- 0.3 mSv for chest CTA. A systolic acquisition window for high-pitch dual-source CTA in patients with high HRs (a parts per thousand yen70 bpm) significantly improves coronary artery image quality at a low radiation dose.
引用
收藏
页码:2565 / 2571
页数:7
相关论文
共 50 条
  • [31] Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: first experience
    Leschka, Sebastian
    Stolzmann, Paul
    Desbiolles, Lotus
    Baumueller, Stephan
    Goetti, Robert
    Schertler, Thomas
    Scheffel, Hans
    Plass, Andre
    Falk, Volkmar
    Feuchtner, Gudrun
    Marincek, Borut
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2009, 19 (12) : 2896 - 2903
  • [32] High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    Beeres, Martin
    Schell, Boris
    Mastragelopoulos, Aristidis
    Herrmann, Eva
    Kerl, Josef Matthias
    Gruber-Rouh, Tatjana
    Lee, Clara
    Siebenhandl, Petra
    Bodelle, Boris
    Zangos, Stephan
    Vogl, Thomas J.
    Jacobi, Volkmar
    Bauer, Ralf W.
    EUROPEAN RADIOLOGY, 2012, 22 (01) : 129 - 137
  • [33] High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience
    Martin Beeres
    Boris Schell
    Aristidis Mastragelopoulos
    Eva Herrmann
    Josef Matthias Kerl
    Tatjana Gruber-Rouh
    Clara Lee
    Petra Siebenhandl
    Boris Bodelle
    Stephan Zangos
    Thomas J. Vogl
    Volkmar Jacobi
    Ralf W. Bauer
    European Radiology, 2012, 22 : 129 - 137
  • [34] Feasibility of high-pitch spiral dual-source CT angiography in children with complex congenital heart disease compared to retrospective-gated spiral acquisition
    Li, T.
    Zhao, S.
    Liu, J.
    Yang, L.
    Huang, Z.
    Li, J.
    Luo, C.
    Li, X.
    CLINICAL RADIOLOGY, 2017, 72 (10) : 864 - 870
  • [35] Radiation doses from phantom measurements at high-pitch dual-source computed tomography coronary angiography
    Goetti, Robert
    Leschka, Sebastian
    Boschung, Markus
    Mayer, Sabine
    Wyss, Christophe
    Stolzmann, Paul
    Frauenfelder, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : 773 - 779
  • [36] Evaluating Low-kV Dual-source CT Angiography by High-pitch Spiral Acquisition and Iterative Reconstruction in Pediatric Congenital Heart Disease Patients
    Marukawa, Yohei
    Sato, Shuhei
    Tanaka, Takashi
    Tada, Akihiro
    Kanie, Yuichiro
    Kanazawa, Susumu
    ACTA MEDICA OKAYAMA, 2017, 71 (05) : 407 - 412
  • [37] Feasibility and Radiation Dose of High-Pitch Acquisition Protocols in Patients Undergoing Dual-Source Cardiac CT
    Sommer, Wieland H.
    Albrecht, Edda
    Bamberg, Fabian
    Schenzle, Jan C.
    Johnson, Thorsten R.
    Neumaier, Klement
    Reiser, Maximilian F.
    Nikolaou, Konstatin
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : 1306 - 1312
  • [38] Is ECG triggering for motion artefact reduction in dual-source CT angiography of the ascending aorta still required with high-pitch scanning? The role of ECG-gating in high-pitch dual-source CT of the ascending aorta
    Wielandner, Alice
    Beitzke, Dietrich
    Schernthaner, Ruediger
    Wolf, Florian
    Langenberger, Christina
    Stadler, Alfred
    Loewe, Christian
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1064):
  • [39] Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography
    Araoz, Philip A.
    Kirsch, Jacobo
    Primak, Andrew N.
    Braun, Natalie N.
    Saba, Osama
    Williamson, Eric E.
    Harmsen, W. Scott
    Mandrekar, Jayawant N.
    McCollough, Cynthia H.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (08): : 837 - 845
  • [40] Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography
    Philip A. Araoz
    Jacobo Kirsch
    Andrew N. Primak
    Natalie N. Braun
    Osama Saba
    Eric E. Williamson
    W. Scott Harmsen
    Jayawant N. Mandrekar
    Cynthia H. McCollough
    The International Journal of Cardiovascular Imaging, 2009, 25 : 837 - 845