MRI for the assessment of malignancy in BI-RADS 4 mammographic microcalcifications

被引:28
作者
Bennani-Baiti, Barbara [1 ,2 ]
Dietzel, Matthias [3 ]
Baltzer, Pascal A. [2 ]
机构
[1] Univ Vienna, Dept Pharmaceut Chem, Vienna, Austria
[2] Med Univ Vienna, Vienna Gen Hosp AKH, Dept Biomed Imaging & Image Guided Therapy, Vienna, Austria
[3] Univ Erlangen Nurnberg, Dept Radiol, Nurnberg, Germany
关键词
HIGH-SPATIAL-RESOLUTION; CARCINOMA IN-SITU; BREAST MRI; SCREENING MAMMOGRAPHY; LESIONS; CANCER; RISK; METAANALYSIS; ENHANCEMENT; MULTICENTER;
D O I
10.1371/journal.pone.0188679
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose Assess the performance of breast MRI to diagnose breast cancer in BI-RADS 4 microcalcifications detected by mammography. Materials and methods This retrospective, IRB-approved study included 248 consecutive contrast-enhanced breast MRI (1.5T, protocol in accordance with EUSOBI recommendations) performed to further diagnose BI-RADS 4 microcalcifications detected at mammography during a 3-year period. Standard of reference had to be established by histopathology. Routine consensus reading results by two radiologists were dichotomized as positive or negative and compared with the reference standard (benign vs malignant) to calculate diagnostic parameters. Results There were 107 malignant and 141 benign microcalcifications. Malignancy rates were 18.3% (23/126 BI-RADS 4a), 41.7% (25/60 BI-RADS 4b) and 95% (59/62 BI-RADS 4c). There were 103 true-positive, 116 true-negative, 25 false-positive, and 4 false-negative (one invasive cancer, three DCIS; 2 BI-RADS 4c, 1 BI-RADS 4b on mammography) breast MRI findings, effecting a sensitivity, specificity, PPV, and NPV of 96.3% (95%-CI 90.7-99.0%), 82.3% (95%-CI 75.0-88.2%), 80.5% (95%-CI 72.5-87.0%) and 96.7% (95%-CI 91.7-99.1%), respectively. Conclusion MRI is an accurate tool to further diagnose BI-RADS 4a and 4b microcalcifications and may be helpful to avoid unnecessary biopsies in BI-RADS 4a and 4b lesions. BI-RADS 4c microcalcifications should be biopsied irrespective of MRI findings.
引用
收藏
页数:10
相关论文
共 35 条
[1]  
[Anonymous], ACR PRACTICE PARAMET
[2]   Lesion type and reader experience affect the diagnostic accuracy of breast MRI: A multiple reader ROC study [J].
Baltzer, Pascal A. T. ;
Kaiser, Werner Alois ;
Dietzel, Matthias .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (01) :86-91
[3]   False-Positive Findings at Contrast-Enhanced Breast MRI: A BI-RADS Descriptor Study [J].
Baltzer, Pascal A. T. ;
Benndorf, Matthias ;
Dietzel, Matthias ;
Gajda, Mieczyslaw ;
Runnebaum, Ingo B. ;
Kaiser, Werner A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (06) :1658-1663
[4]  
Bennani-Baiti B, 2016, RADIOLOGY
[5]   Diagnostic Performance of Breast Magnetic Resonance Imaging in Non-Calcified Equivocal Breast Findings: Results from a Systematic Review and Meta-Analysis [J].
Bennani-Baiti, Barbara ;
Bennani-Baiti, Nabila ;
Baltzer, Pascal A. .
PLOS ONE, 2016, 11 (08)
[6]   Comparison of Digital Screening Mammography and Screen-Film Mammography in the Early Detection of Clinically Relevant Cancers: A Multicenter Study [J].
Bluekens, Adriana M. J. ;
Holland, Roland ;
Karssemeijer, Nico ;
Broeders, Mireille J. M. ;
den Heeten, Gerard J. .
RADIOLOGY, 2012, 265 (03) :707-714
[7]  
Castronovo V, 1998, INT J ONCOL, V12, P305
[8]   A new method to reduce false positive results in breast MRI by evaluation of multiple spectral regions in proton MR-spectroscopy [J].
Clauser, Paola ;
Marcon, Magda ;
Dietzel, Matthias ;
Baltzer, Pascal A. T. .
EUROPEAN JOURNAL OF RADIOLOGY, 2017, 92 :51-57
[9]  
DOrsi C., 2013, ACR BIRADS. atlas, breast imaging reporting and data sys-tem, V5th
[10]   The natural history of ductal carcinoma in situ of the breast:: a review [J].
Erbas, B ;
Provenzan, E ;
Armes, J ;
Gertig, D .
BREAST CANCER RESEARCH AND TREATMENT, 2006, 97 (02) :135-144