Outcome of zirconia partial fixed dental prostheses made by predoctoral dental students: A clinical retrospective study after 3 to 7 years of clinical service

被引:26
作者
Pihlaja, Juha [1 ,2 ]
Napankangas, Ritva [1 ,2 ]
Raustia, Aune [1 ,2 ]
机构
[1] Univ Oulu, Fac Med, Res Ctr Oral Hlth Sci, Oulu, Finland
[2] Med Res Ctr, Oulu, Finland
关键词
PARTIAL DENTURES; SINGLE CROWNS; MONOLITHIC ZIRCONIA; SURVIVAL; PERFORMANCE; RATES; COMPLICATIONS; DESIGN; FDPS;
D O I
10.1016/j.prosdent.2015.10.026
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Zirconia has an established role in fixed prosthodontics, especially for single crowns. Whether it is durable enough for fixed dental prostheses (FDPs) in the long term is yet unclear. Purpose. The purpose of this retrospective study was to evaluate the outcome of FDPs made by predoctoral students after 3 to 7 years of clinical service. Material and methods. A total of 102 patients received 120 zirconia FDPs (range, 3-12 units; mean, 4.5 units) between 2007 and 2010. Materials used were Zirkonzahn Zirconia (Zirkonzahn), Nobel-Procera Zirconia (Nobel Biocare), and Prettau Zirconia (Zirkonzahn). Veneering porcelain was hand layered on Zirkonzahn Zirconia (GC Initial Zr; GC Europe) and Nobel Procera Zirconia (VITA VM 9; VITA Zahnfabrik). Prettau Zirconia was monolithic and had no veneering porcelain. Success and survival rates were calculated using Kaplan-Meier survival analysis. Ethics approval was obtained from the Ethical Committee of the Northern Ostrobothnia Hospital District (100/2013). Results. The 76 participants examined (75%) had received 88 zirconia FDPs. The mean follow-up period was 4.9 years (range, 3-7 years). The most common complication was chipping of the veneering porcelain in 13 of 88 FDPs (14.7%). The success rate of the zirconia-based partial FDPs after 4.9 years was 89%, and the survival rate was 100%. Conclusions. The success rate of the zirconia-based partial FDPs after 4.9 years was 89%, and the survival rate was 100%.
引用
收藏
页码:40 / 46
页数:7
相关论文
共 36 条
  • [1] Agustín-Panadero R, 2012, INT J PROSTHODONT, V25, P294
  • [2] Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses
    Anusavice, Kenneth J.
    [J]. DENTAL MATERIALS, 2012, 28 (01) : 102 - 111
  • [3] Current theories of crown contour, margin placement, and pontic design
    Becker, CM
    Kaldahl, WB
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (02) : 107 - 115
  • [4] Ten-year clinical outcome of three-unit posterior FDPs made from a glass-infiltrated zirconia reinforced alumina ceramic (In-Ceram Zirconia)
    Chaar, M. Sad
    Passia, Nicole
    Kern, Matthias
    [J]. JOURNAL OF DENTISTRY, 2015, 43 (05) : 512 - 517
  • [5] Survival Rates of a Lithium Disilicate-Based Core Ceramic for Three-Unit Esthetic Fixed Partial Dentures: A 10-Year Prospective Study
    Fernanda Sola-Ruiz, M.
    Lagos-Flores, Elena
    Luis Roman-Rodriguez, Juan
    Del Rio Highsmith, Jaime
    Fons-Font, Antonio
    Granell-Ruiz, Maria
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (02) : 175 - 180
  • [6] A prospective evaluation of zirconia anterior partial fixed dental prostheses: Clinical results after seven years
    Fernanda Sola-Ruiz, Maria
    Agustin-Panadero, Ruben
    Fons-Font, Antonio
    Labaig-Rueda, Carlos
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (06) : 578 - 584
  • [7] Griggs Jason A, 2007, Dent Clin North Am, V51, P713, DOI 10.1016/j.cden.2007.04.006
  • [8] Effect of core design and veneering technique on damage and reliability of Y-TZP-supported crowns
    Guess, Petra C.
    Bonfante, Estevam A.
    Silva, Nelson R. F. A.
    Coelho, Paulo G.
    Thompson, Van P.
    [J]. DENTAL MATERIALS, 2013, 29 (03) : 307 - 316
  • [9] FDI World Dental Federation: clinical criteria for the evaluation of direct and indirect restorations-update and clinical examples
    Hickel, Reinhard
    Peschke, Arnd
    Tyas, Martin
    Mjoer, Ivar
    Bayne, Stephen
    Peters, Mathilde
    Hiller, Karl-Anton
    Randall, Ross
    Vanherle, Guido
    Heintze, Siegward D.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2010, 14 (04) : 349 - 366
  • [10] Bonding to oxide ceramics-Laboratory testing versus clinical outcome
    Kern, Matthias
    [J]. DENTAL MATERIALS, 2015, 31 (01) : 8 - 14