The influence of location on solar photo-Fenton: Process performance, photoreactor scaling-up and treatment cost

被引:33
作者
Cabrera Reina, A. [1 ]
Miralles-Cuevas, S. [1 ]
Cornejo, L. [1 ]
Pomares, L. [2 ]
Polo, J. [3 ]
Oller, I. [4 ,5 ]
Malato, S. [4 ,5 ]
机构
[1] Univ Tarapaca, Univ Sch Mech Engn EUDIM, Avda Gen Velasquez, Arica, Chile
[2] Hamad Bin Khalifa Univ, Qatar Environm & Energy Res Inst, POB 5825, Doha, Qatar
[3] Ctr Invest Energet Medioambientales & Tecnol, Madrid, Spain
[4] Plataforma Solar Almeria CIEMAT, Carretera Senes,Km 4, Tabernas, Spain
[5] Joint Ctr Univ Almeria CIEMAT, CIESOL, Ctra Sacramento S-N, Almeria, Spain
关键词
Solar photo-Fenton; Wastewater; Cost analysis; Advanced oxidation processes; Photoreactor; ADVANCED OXIDATION PROCESSES; WASTE-WATER; PESTICIDES; MICROCONTAMINANTS; DECONTAMINATION; PHOTOCATALYSIS; NANOFILTRATION; TECHNOLOGIES; STRATEGIES;
D O I
10.1016/j.renene.2019.07.113
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The efficiency of solar photo-Fenton treatment is related to ambient conditions, as it depends on solar irradiance levels and operation temperature, consequently, it is highly influenced by plant location. In this context, solar photo-Fenton feasibility in three Sunbelt cities (Tabernas -Spain-, Arica -Chile- and Doha -Qatar-) for the treatment of industrial wastewater has been analysed. Process performance was simulated by means of a semi-empirical photo-Fenton model comparing the results obtained with yearly average ambient conditions and the most unfavourable monthly ambient conditions. This data was used with scaling-up purposes in order to determine the photoreactor size and reservoir tank volume needed for each case. Finally, an economical assessment was carried out. Doha presented the lowest total costs (TC), 2.23 (sic)/m(3), followed by Arica with 2.45 (sic)/m(3) and Tabernas with 2.67 (sic)/m(3) for the method based on yearly averages. For the most unfavourable ambient conditions method, the TCs were slightly higher resulting in 2.29, 2.55 and 3.11 (sic)/m(3), respectively. Cost breakdowns were analogous independently of scaling-up method and location, being amortization costs (ACs) more influenced by location than operation costs (OCs). (c) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1890 / 1900
页数:11
相关论文
共 35 条
  • [1] [Anonymous], 2013, 2013 ISES SOL WORLD
  • [2] Antonakaki T., 2014, VALIDATION REPORT MA
  • [3] Effects of environmental variables on the photo-Fenton plant design
    Cabrera Reina, A.
    Casas Lopez, J. L.
    Maldonado Rubio, M. I.
    Santos-Juanes Jorda, L.
    Garcia Sanchez, J. L.
    Sanchez Perez, J. A.
    [J]. CHEMICAL ENGINEERING JOURNAL, 2014, 237 : 469 - 477
  • [4] Cost analysis of different hydrogen peroxide supply strategies in the solar photo-Fenton process
    Carra, Irene
    Ortega-Gomez, Elisabet
    Santos-Juanes, Lucas
    Casas Lopez, Jose Luis
    Sanchez Perez, Jose Antonio
    [J]. CHEMICAL ENGINEERING JOURNAL, 2013, 224 : 75 - 81
  • [5] A through analysis of solar irradiation measurements in the region of Arica Parinacota, Chile
    Cornejo, Lorena
    Martin-Pomares, Luis
    Alarcon, Diego
    Blanco, Julian
    Polo, Jesus
    [J]. RENEWABLE ENERGY, 2017, 112 : 197 - 208
  • [6] Kinetic study of the photo-Fenton degradation of formic acid Combined effects of temperature and iron concentration
    Farias, Jorgelina
    Albizzati, Enrique D.
    Alfano, Orlando M.
    [J]. CATALYSIS TODAY, 2009, 144 (1-2) : 117 - 123
  • [7] Solar photo-Fenton treatment -: Process parameters and process control
    Gernjak, W
    Fuerhacker, M
    Fernández-Ibañez, P
    Blanco, J
    Malato, S
    [J]. APPLIED CATALYSIS B-ENVIRONMENTAL, 2006, 64 (1-2) : 121 - 130
  • [8] A review of imperative technologies for wastewater treatment I: oxidation technologies at ambient conditions
    Gogate, PR
    Pandit, AB
    [J]. ADVANCES IN ENVIRONMENTAL RESEARCH, 2004, 8 (3-4): : 501 - 551
  • [9] Clear-sky irradiance predictions for solar resource mapping and large-scale applications: Improved validation methodology and detailed performance analysis of 18 broadband radiative models
    Gueymard, Christian A.
    [J]. SOLAR ENERGY, 2012, 86 (08) : 2145 - 2169
  • [10] Supported Fe/C and Fe/Nafion/C catalysts for the photo-Fenton degradation of Orange II under solar irradiation
    Gumy, D
    Fernández-Ibánez, P
    Malato, S
    Pulgarin, C
    Enea, O
    Kiwi, J
    [J]. CATALYSIS TODAY, 2005, 101 (3-4) : 375 - 382