Crowding can impact both low and high contrast visual acuity measurements

被引:0
作者
Pluhacek, Frantisek [1 ]
Siderov, John [2 ]
Machacova, Ivana [1 ]
机构
[1] Palacky Univ Olomouc, Dept Opt, Olomouc, Czech Republic
[2] Univ Huddersfield, Ctr Vis Across Life Span, Dept Optometry & Vis Sci, Huddersfield HD1 3DH, W Yorkshire, England
关键词
FOVEAL CONTOUR INTERACTION; VISION; REPEATABILITY; INTERFERENCE; VARIABILITY; VALIDITY; DESIGN; CHARTS; TESTS;
D O I
10.1038/s41598-022-20479-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The adverse impact of adjacent contours on letter visual acuity is known as crowding but there is conflicting evidence that foveal crowding may be reduced or disappears under low contrast conditions. Potential differences in foveal crowding with contrast on clinical measurements of visual acuity, including test-retest repeatability, were assessed. Visual acuity was measured at the fovea on adult participants with normal vision under three different contrast levels (- 90, - 10 and - 5%). Three rows of 5 letters, each row differing in size by 0.05 logarithm of the minimum angle of resolution (logMAR) from largest to smallest were displayed at the center of a monitor. Crowding was varied by varying the separation between horizontally adjacent letters from 100% optotype size to 50%, 20% and 10% optotype size. Inter-row spacing was proportional to optotype size. Observers read the letters on the middle row only. Measurements continued by reducing the size of the letters until 3 or more errors were made and were repeated on two separate days. Visual acuity worsened as both letter contrast decreased and inter-optotype separation reduced (expressed as a percentage of letter width). When expressed in minutes of arc of separation the impact of crowding was the same across all contrasts. Crowding occurs for both high and low contrast charts and should be considered when assessing low contrast visual acuity. Test-retest repeatability showed little or no dependence on either contrast or inter-optotype separation.
引用
收藏
页数:9
相关论文
共 59 条
  • [1] Atkinson J., 1986, Doc Ophthalmol Proc Ser, V45, P201
  • [2] Bailey I. L., 2020, OPHTH VIS OPT NON AS
  • [3] Bailey IL., 1998, BORISHS CLIN REFRACT, P179
  • [4] Validity of low-contrast letter acuity as a visual performance outcome measure for multiple sclerosis
    Balcer, Laura J.
    Raynowska, Jenelle
    Nolan, Rachel
    Galetta, Steven L.
    Kapoor, Raju
    Benedict, Ralph
    Phillips, Glenn
    LaRocca, Nicholas
    Hudson, Lynn
    Rudick, Richard
    [J]. MULTIPLE SCLEROSIS JOURNAL, 2017, 23 (05) : 734 - 747
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] HIGH AND LOW CONTRAST ACUITY AND CLINICAL CONTRAST SENSITIVITY TESTED IN A NORMAL POPULATION
    BROWN, B
    LOVIEKITCHIN, JE
    [J]. OPTOMETRY AND VISION SCIENCE, 1989, 66 (07) : 467 - 473
  • [7] INTERFERENCE WITH STEREOSCOPIC ACUITY - SPATIAL, TEMPORAL, AND DISPARITY TUNING
    BUTLER, TW
    WESTHEIMER, G
    [J]. VISION RESEARCH, 1978, 18 (10) : 1387 - 1392
  • [8] Exact Parametric Confidence Intervals for Bland-Altman Limits of Agreement
    Carkeet, Andrew
    [J]. OPTOMETRY AND VISION SCIENCE, 2015, 92 (03) : E71 - E80
  • [9] Repeatability of the Waterloo four-contrast LogMAR visual acuity chart and near vision test card on a group of normal young adults
    Cho, P
    Woo, GC
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2004, 24 (05) : 427 - 435
  • [10] Spatial-frequency and contrast properties of crowding
    Chung, STL
    Levi, DM
    Legge, GE
    [J]. VISION RESEARCH, 2001, 41 (14) : 1833 - 1850