A new method to measure air-borne pyrogens based on human whole blood cytokine response

被引:24
作者
Kindinger, I
Daneshian, M
Baur, H
Gabrio, T
Hofmann, A
Fennrich, S
von Aulock, S
Hartung, T
机构
[1] Univ Konstanz, D-78457 Constance, Germany
[2] Landwirtschaft Berufsgenossenschaft Baden Wurttem, D-70199 Stuttgart, Germany
[3] Landesgesundheitsamt Baden Wurttemberg, D-70174 Stuttgart, Germany
[4] Phytos, D-89231 Ulm, Germany
[5] EU Joint Res Ctr, ECVAM, I-21020 Ispra, Italy
关键词
air-borne pyrogens; pyrogen test; air quality;
D O I
10.1016/j.jim.2005.01.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Air-borne microorganisms, as well as their fragments and components, are increasingly recognized to be associated with pulmonary diseases, e.g. organic dust toxic syndrome, humidifier lung, building-related illness, "Monday sickness." We have previously described and validated a new method for the detection of pyrogenic (fever-inducing) microbial contaminations in injectable drugs, based on the inflammatory reaction of human blood to pyrogens. We have now adapted this test to evaluate the total inflammatory capacity of air samples. Air was drawn onto PTFE membrane filters, which were incubated with human whole blood from healthy volunteers inside the collection device. Cytokine release was measured by ELISA. The test detects endotoxins and non-endotoxins, such as fungal spores, Gram-positive bacteria and their lipoteichoic acid moiety and pyrogenic dust particles with high sensitivity, thus reflecting the total inflammatory capacity of a sample. When air from different surroundings such as working environments and animal housing was assayed, the method yielded reproducible data which correlated with other parameters of microbial burden tested. We further developed a standard material for quantification and showed that this assay can be performed with cryopreserved as well as fresh blood. The method offers a test to measure the integral inflammatory capacity of air-borne microbial contaminations relevant to humans. It could thus be employed to assess air quality in different living and work environments. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:143 / 153
页数:11
相关论文
共 18 条
[1]   ASSESSMENT OF DUST AND ENDOTOXIN LEVELS IN THE WORKING ENVIRONMENT OF DUTCH PIG FARMERS - A PRELIMINARY-STUDY [J].
ATTWOOD, P ;
VERSLOOT, P ;
HEEDERIK, D ;
DEWIT, R ;
BOLEIJ, JSM .
ANNALS OF OCCUPATIONAL HYGIENE, 1986, 30 (02) :201-208
[2]  
Boneberg EM, 2002, EUR J IMMUNOL, V32, P1717, DOI 10.1002/1521-4141(200206)32:6<1717::AID-IMMU1717>3.0.CO
[3]  
2-N
[4]   Relevance of airborne fungi and their secondary metabolites for environmental, occupational and indoor hygiene [J].
Fischer, G ;
Dott, W .
ARCHIVES OF MICROBIOLOGY, 2003, 179 (02) :75-82
[5]   Comparison and validation of novel pyrogen tests based on the human fever reaction [J].
Hartung, T .
ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2002, 30 :49-51
[6]  
Hartung Thomas, 1995, ALTEX, V12, P70
[7]   A model of human whole blood lymphokine release for in vitro and ex vivo use [J].
Hermann, C ;
von Aulock, S ;
Graf, K ;
Hartung, T .
JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 275 (1-2) :69-79
[8]  
HOFFMANN S, 2005, TOXICOL SCI 0202
[9]  
KENNEDY SM, 1987, AM REV RESPIR DIS, V135, P194
[10]  
Milton DK, 1996, AM J IND MED, V29, P3, DOI 10.1002/(SICI)1097-0274(199601)29:1<3::AID-AJIM2>3.0.CO