Comparative study of floating and dynamic injection modes in electrokinetic separative microsystems

被引:2
作者
Blas, Maximilien [1 ]
Delaunay, Nathalie [1 ]
Rocca, Jean-Louis [1 ]
机构
[1] Univ Lyon 1, CNRS, UMR 5180, Sci Analyt Lab, F-69622 Villeurbanne, France
关键词
amino acid; electrokinetic injection; electrophoresis; separation chip;
D O I
10.1002/elps.200700011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Miniaturization of analytical instruments has attracted a wide interest in analytical chemistry over the past decade because of the advantages of reduced reagent consumption, better analytical performance, and shorter analysis time. The widespread interest in this field has resulted in efforts to develop chips. For chips involving separation, injection is a key step to achieve efficient and sensitive analysis. This work presents a comparative study of two electrokinetic injection modes in chips: the floating, which has been mainly used up to now, and the dynamic. This study was done with a crossjunction, either with numerical simulations or with experiments. Experiments were carried out with homemade PDMS-glass microsystems involving zonal electrophoresis analysis of five derivatized amino acids. Injected amount, reproducibility, separation efficiency, and analyte discrimination were evaluated and discussed. The experimental results were successfully correlated with numerical simulations. It appeared that the dynamic injection mode is much more appropriate than the floating mode as it is faster (reduction by a factor 2 of the total analysis time here), more reproducible (RSD of peak areas equal to 1.3% (n = 4) instead of 10% (n = 4)), and leads to more efficient separation (about 20% with 3 cm separation channel length) for the same injected amount, whatever the amount, because the sample plug is less dispersed.
引用
收藏
页码:4629 / 4637
页数:9
相关论文
共 42 条
[1]  
Alarie JP, 2000, ELECTROPHORESIS, V21, P100, DOI 10.1002/(SICI)1522-2683(20000101)21:1<100::AID-ELPS100>3.3.CO
[2]  
2-G
[3]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[4]  
Bharadwaj R, 2002, ELECTROPHORESIS, V23, P2729, DOI 10.1002/1522-2683(200208)23:16<2729::AID-ELPS2729>3.0.CO
[5]  
2-I
[6]   Numerical simulations of the second-order electrokinetic bias observed with the gated injection mode in chips [J].
Blas, Maximilien ;
Delaunay, Nathalie ;
Ferrigno, Rosaria ;
Rocca, Jean-Louis .
ELECTROPHORESIS, 2007, 28 (17) :2961-2970
[7]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[8]  
2-M
[9]  
Deshpande M, 2000, MESA MG, P339
[10]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984