Importance of saline contrast transthoracic echocardiography for evaluating large right-to-left shunt in patent foramen ovale associated with cryptogenic stroke

被引:9
作者
Takaya, Yoichi [1 ]
Nakayama, Rie [1 ]
Akagi, Teiji [1 ]
Yokohama, Fumi [1 ]
Miki, Takashi [1 ]
Nakagawa, Koji [1 ]
Toh, Norihisa [1 ]
Ito, Hiroshi [1 ]
机构
[1] Okayama Univ, Grad Sch Med, Dept Cardiovasc Med Dent & Pharmaceut Sci, Kita Ku, 2-5-1 Shikata Cho, Okayama 7008558, Japan
关键词
Patent foramen ovale; Right-to-left shunt; Cryptogenic stroke; Transthoracic echocardiography; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; CLOSURE; RISK; EMBOLISM; THERAPY;
D O I
10.1007/s10554-021-02418-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transcatheter closure of patent foramen ovale (PFO) is an effective therapy for preventing recurrent stroke in very specific patient cohorts, such as cryptogenic stroke (CS). The identification of high-risk PFO, which is more likely to be linked to CS, is essential. This study aimed to assess the accuracy of saline contrast transthoracic echocardiography (TTE) for evaluating large right-to-left (RL) shunt. We enrolled 119 patients with or without CS who were confirmed to have PFO by transesophageal echocardiography (TEE) or catheterization. The severity of RL shunt evaluated by TTE and TEE was classified as follows: small (< 10 microbubbles), moderate (10-20 microbubbles), and large (> 20 microbubbles). With TTE, large RL shunt was observed in 94 (79%) of 119 patients, including 66 of 74 with CS and 28 of 45 without CS. With TEE, large RL shunt was observed in 33 (28 %) patients, including 26 with CS and 7 without CS. TTE showed large RL shunt more frequently than TEE (p < 0.01). Large RL shunt evaluated by TTE had a sensitivity of 89 % and an accuracy of 70 % for the association with CS, whereas large RL shunt evaluated by TEE had a sensitivity of 35% and an accuracy of 56 %. Accuracy was significantly greater in TTE than in TEE (p = 0.02). In conclusion, TTE identified large RL shunt associated with CS with higher sensitivity and accuracy compared to TEE. Our findings suggest that the decision for device closure should be made based on the severity of RL shunt by TTE.
引用
收藏
页码:515 / 520
页数:6
相关论文
共 23 条
[1]  
Clarke N R A, 2004, Eur J Echocardiogr, V5, P176, DOI 10.1016/S1525-2167(03)00076-3
[2]   Morphological and functional characteristics of patent foramen ovale and their embolic implications [J].
De Castro, S ;
Cartoni, D ;
Fiorelli, M ;
Rasura, M ;
Anzini, A ;
Zanette, EM ;
Beccia, M ;
Colonnese, C ;
Fedele, F ;
Fieschi, C ;
Pandian, NG .
STROKE, 2000, 31 (10) :2407-2413
[3]   Platypnea-orthodeoxia syndrome related to an aortic aneurysm combined with an aneurysm of the atrial septum [J].
Faller, M ;
Kessler, R ;
Chaouat, A ;
Ehrhart, M ;
Petit, H ;
Weitzenblum, E .
CHEST, 2000, 118 (02) :553-557
[4]   Morphology of the Patent Foramen Ovale in Asymptomatic Versus Symptomatic (Stroke or Transient Ischemic Attack) Patients [J].
Goel, Sachin S. ;
Tuzcu, E. Murat ;
Shishehbor, Mehdi H. ;
de Oliveira, Eduardo F. ;
Borek, Przernyslaw P. ;
Krasuski, Richard A. ;
Rodriguez, Leonardo L. ;
Kapadia, Sarnir R. .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (01) :124-129
[5]   Patent foramen ovale: Current pathology, pathophysiology, and clinical status [J].
Hara, H ;
Virmani, R ;
Ladich, E ;
Mackey-Bojack, S ;
Titus, J ;
Reisman, M ;
Gray, W ;
Nakamura, M ;
Mooney, M ;
Poulose, A ;
Schwartz, RS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (09) :1768-1776
[6]   CHARACTERISTICS OF PATENT FORAMEN OVALE ASSOCIATED WITH CRYPTOGENIC STROKE - A BIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHIC STUDY [J].
HOMMA, S ;
DITULLIO, MR ;
SACCO, RL ;
MIHALATOS, D ;
MANDRI, GL ;
MOHR, JP .
STROKE, 1994, 25 (03) :582-586
[7]   COMPARISON OF TRANSCRANIAL CONTRAST DOPPLER SONOGRAPHY AND TRANSESOPHAGEAL CONTRAST ECHOCARDIOGRAPHY FOR THE DETECTION OF PATENT FORAMEN OVALE IN YOUNG STROKE PATIENTS [J].
JOB, FP ;
RINGELSTEIN, EB ;
GRAFEN, Y ;
FLACHSKAMPF, FA ;
DOHERTY, C ;
STOCKMANNS, A ;
HANRATH, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (04) :381-384
[8]   Patent foramen ovale: A review of associated conditions and the impact of physiological size [J].
Kerut, EK ;
Norfleet, WT ;
Plotnick, GD ;
Giles, TD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (03) :613-623
[9]   The Effect of Patent Foramen Ovale Closure on Visual Aura Without Headache or Typical Aura With Migraine Headache [J].
Khessali, Hamidreza ;
Mojadidi, M. Khalid ;
Gevorgyan, Rubine ;
Levinson, Ralph ;
Tobis, Jonathan .
JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (06) :682-687
[10]   Transthoracic echocardiography using second harmonic imaging -: Diagnostic alternative to transesophageal echocardiography for the detection of atrial right to left shunt in patients with cerebral embolic events [J].
Kühl, HP ;
Hoffmann, R ;
Merx, MW ;
Franke, A ;
Klötzsch, C ;
Lepper, W ;
Reineke, T ;
Noth, J ;
Hanrath, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (06) :1823-1830