Systematic prediction error correction: A novel strategy for maintaining the predictive abilities of multivariate calibration models

被引:39
作者
Chen, Zeng-Ping
Li, Li-Mei [1 ]
Yu, Ru-Qin [1 ]
Littlejohn, David [2 ]
Nordon, Alison [2 ]
Morris, Julian [3 ]
Dann, Alison S. [4 ]
Jeffkins, Paul A. [4 ]
Richardson, Mark D. [4 ]
Stimpson, Sarah L. [4 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
[2] Univ Strathclyde, Dept Pure & Appl Chem, WestCHEM, Ctr Proc Analyt & Control Technol, Glasgow G1 1XL, Lanark, Scotland
[3] Newcastle Univ, Sch Chem Engn & Adv Mat, Ctr Proc Analyt & Control Technol, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[4] GlaxoSmithKline Inc, Worthing BN14 8QH, W Sussex, England
基金
英国工程与自然科学研究理事会;
关键词
INFRARED SPECTROMETRIC INSTRUMENTS; STANDARDIZATION PROCEDURE; ORTHOGONAL PROJECTION; SPECTRAL VARIATIONS; GENETIC REGRESSION; SCATTER-CORRECTION; NIR SPECTROSCOPY; NEURAL-NETWORKS; IMPROVEMENT; TRANSFERABILITY;
D O I
10.1039/c0an00171f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of reliable multivariate calibration models for spectroscopic instruments in on-line/in-line monitoring of chemical and bio-chemical processes is generally difficult, time-consuming and costly. Therefore, it is preferable if calibration models can be used for an extended period, without the need to replace them. However, in many process applications, changes in the instrumental response (e.g. owing to a change of spectrometer) or variations in the measurement conditions (e.g. a change in temperature) can cause a multivariate calibration model to become invalid. In this contribution, a new method, systematic prediction error correction (SPEC), has been developed to maintain the predictive abilities of multivariate calibration models when e.g. the spectrometer or measurement conditions are altered. The performance of the method has been tested on two NIR data sets (one with changes in instrumental responses, the other with variations in experimental conditions) and the outcomes compared with those of some popular methods, i.e. global PLS, univariate slope and bias correction (SBC) and piecewise direct standardization (PDS). The results show that SPEC achieves satisfactory analyte predictions with significantly lower RMSEP values than global PLS and SBC for both data sets, even when only a few standardization samples are used. Furthermore, SPEC is simple to implement and requires less information than PDS, which offers advantages for applications with limited data.
引用
收藏
页码:98 / 106
页数:9
相关论文
共 41 条
[1]   Transfer by orthogonal projection: making near-infrared calibrations robust to between-instrument variation [J].
Andrew, A ;
Fearn, T .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2004, 72 (01) :51-56
[2]   Applications of maximum likelihood principal component analysis: incomplete data sets and calibration transfer [J].
Andrews, DT ;
Wentzell, PD .
ANALYTICA CHIMICA ACTA, 1997, 350 (03) :341-352
[3]   Transfer of near-infrared multivariate calibrations without standards [J].
Blank, TB ;
Sum, ST ;
Brown, SD ;
Monfre, SL .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2987-2995
[4]   Standardisation of near-infrared spectrometric instruments: A review [J].
Bouveresse, E ;
Massart, DL .
VIBRATIONAL SPECTROSCOPY, 1996, 11 (01) :3-15
[5]   CALIBRATION TRANSFER ACROSS NEAR-INFRARED SPECTROMETRIC INSTRUMENTS USING SHENKS ALGORITHM - EFFECTS OF DIFFERENT STANDARDIZATION SAMPLES [J].
BOUVERESSE, E ;
MASSART, DL ;
DARDENNE, P .
ANALYTICA CHIMICA ACTA, 1994, 297 (03) :405-416
[6]   Standardization of near-infrared spectrometric instruments [J].
Bouveresse, E ;
Hartmann, C ;
Massart, DL ;
Last, IR ;
Prebble, KA .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :982-990
[7]   MODIFIED ALGORITHM FOR STANDARDIZATION OF NEAR-INFRARED SPECTROMETRIC INSTRUMENTS [J].
BOUVERESSE, E ;
MASSART, DL ;
DARDENNE, P .
ANALYTICAL CHEMISTRY, 1995, 67 (08) :1381-1389
[8]   Improvement of the piecewise direct standardisation procedure for the transfer of NIR spectra for multivariate calibration [J].
Bouveresse, E ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 32 (02) :201-213
[9]   Correction of temperature-induced spectral variations by loading space standardization [J].
Chen, ZP ;
Morris, J ;
Martin, E .
ANALYTICAL CHEMISTRY, 2005, 77 (05) :1376-1384
[10]   Transfer of calibrations of near-infrared spectra using neural networks [J].
Despagne, F ;
Walczak, B ;
Massart, DL .
APPLIED SPECTROSCOPY, 1998, 52 (05) :732-745