Comparison of an analog and digital quantitative and qualitative analysis for the fit of dental copings

被引:26
作者
Kuhn, Katharina [1 ]
Ostertag, Silke [2 ]
Ostertag, Michael [2 ]
Walter, Michael H. [2 ]
Luthardt, Ralph G. [1 ,2 ]
Rudolph, Heike [1 ,2 ]
机构
[1] Univ Ulm, Ctr Dent, Dept Prosthet Dent, D-89081 Ulm, Germany
[2] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Sch Dent, Dept Prosthet Dent, D-01309 Dresden, Germany
关键词
Digitizing; CAD; CAM; Point cloud; Data density; Computer-assisted; Three-dimensional analysis; Dental restoration fit; Replica-technique; INTERNAL FIT; CLINICAL FIT; MARGINAL FIT; CROWNS; ACCURACY; ADAPTATION; TITANIUM;
D O I
10.1016/j.compbiomed.2014.11.017
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Precision in fit is crucial for dental crowns and bridges. Most analyses of fit are based on analog 2D techniques. Aim of this in-vitro study was to compare an analog and a digital quantitative and qualitative analysis for the fit of CAD/CAM fabricated dental copings. Methods: A prepared steel canine served as master die. CAD surface models, varying in data density, were purposely enlarged in height (Ez), circumference (Exy) and both of these aspects at once (Exyz). Two titanium copings for each variation were produced. The silicone-replica-technique was applied to analyze the fit by means of a 2D analog light microscope measurement (LMM) and a 3D computer-assisted measurement using an optical digitizing system (ODKM97), respectively. Results: In most cases, restorations based on the low data density showed a better fit than those based on high data density. Original size low density data showed the lowest marginal and axial values in the quantitative 2D analyses (LMM and ODKM97). The 3D measurements (ODKM97) revealed best fit of the low density original size specimens, whereas the Ez specimens showed the highest values. Noticeable variations in fit were detected marginally and axially depending on the specific measurement point (mesial, distal, oral, or buccal) for both measurement systems. Discussion: The analog 2D replica technique revealed a loss of information due to the necessary cutting process. By contrast, the digital computer-based method provided 3D quantitative and qualitative results without data loss over the complete surface. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:32 / 41
页数:10
相关论文
共 40 条
[1]  
Barone Monfrin S., 2006, MINERVA STOMATOL, V55, P381
[2]  
Beuer F, 2009, QUINTESSENCE INT, V40, P243
[3]   Clinical fit of Procera AllCeram crowns [J].
Boening, KW ;
Wolf, BH ;
Schmidt, AE ;
Kästner, K ;
Walter, MH .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (04) :419-424
[4]  
Chan C, 1989, Quintessence Int, V20, P189
[5]   Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining [J].
Contreras, EFR ;
Henriques, GEP ;
Giolo, SR ;
Nobilo, MAA .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 88 (05) :467-472
[6]  
Cook K T, 2012, Int J Comput Dent, V15, P315
[7]  
Gassino G, 2004, INT J PROSTHODONT, V17, P218
[8]   Determination of the minimum number of marginal gap measurements required for practical in vitro testing [J].
Groten, M ;
Axmann, D ;
Pröbster, L ;
Weber, H .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (01) :40-49
[9]   MARGINAL ACCURACY AND INTERNAL FIT OF MACHINE-MILLED AND CAST TITANIUM CROWNS [J].
Han, Hyun-Sook ;
Yang, Hong-So ;
Lim, Hyun-Pil ;
Park, Yeong-Joon .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (03) :191-197
[10]  
Hickel R, 1997, Int Dent J, V47, P247