Study Design. Directions of the C1-C2 posterior transarticular screw trajectories making the longest path or violating the transverse foramen were measured by using an objective measuring method. Objectives. To clarify the directions of the screw trajectory marking the longest paths without violating the transverse foramen. To achieve this, diverse directions of the screw trajectories were objectified by measuring the locations of the points of screw intersection on the superior articular surface of C2. Summary of Background Data. The principal limitation of posterior C1-C2 posterior transarticular screw fixation is the location of the vertebral artery. Because of the lack of an objective measuring method, surgical unsuitability has been decided on the basis of individual experiences as reported in 18% to 23% of cases. Methods. Sagittal reconstructed computed tomographic images were made at 3.5 mm and 6 mm from the spinal canal. C2-C2 transarticular screw trajectories making the longest path or violating the transverse foramen (dangerous trajectory) were drawn, and their points of screw intersection on the superior articular surface of C2 were measured from the posterior rim of the superior articular surface of C2. When the space I: available for the screw behind the points of screw intersection by the dangerous trajectory was equal to or less than 3.5 mm, the case was defined as "unacceptable"; wen the space available for the screw was more than 3.5 mm but equal to or less than 4.5 mm, it was defined as "risky" for the placement of the screw. Results. Trajectories make the longest paths when they pass an average of 3.6 mm and 2.8 mm anterior to the posterior rim of the posterior articular surface of C2 at 3.5-mm lateral images and 6-mm lateral images, respectively. Four of 64 cases were unacceptable or risky unilaterally on 3.5-mm lateral images, and 21 cases were unacceptable or risky on 6-mm lateral images. A sigmoid-shaped increment curve of the risk was noted as the increasing forward inclination of the screw trajectories increased. Conclusions. The areas on the superior articular surface of C2 intersected by the trajectories making the longest paths without violating the transverse foramen are clarified as a guide to the ideal and safe trajectories, The theoretical minimal risk and usual risk of the posterior C1-C2 transarticular screw fixation are presented as well.
引用
收藏
页码:1703 / 1707
页数:5
相关论文
共 50 条
  • [31] Anatomic variation of the vertebral artery: a case involving a persistent first intersegmental artery at C1-C2
    Zeng, Tao
    Qiao, Jinsheng
    Su, Changrui
    Zeng, Yixuan
    Sun, Guodong
    Dang, Zhenhua
    Zhang, Guohong
    Tang, Wenlong
    SURGICAL AND RADIOLOGIC ANATOMY, 2024, 46 (11) : 1795 - 1799
  • [32] Biomechanical Evaluation of an Atlantoaxial Lateral Mass Fusion Cage With C1-C2 Pedicle Fixation
    Li, Songkai
    Ni, Bin
    Xie, Ning
    Wang, Mingfei
    Guo, Xiang
    Zhang, Feng
    Wang, Jian
    Zhao, Weidong
    SPINE, 2010, 35 (14) : E624 - E632
  • [33] Isocentric C-arm three-dimensional navigation versus conventional C-arm assisted C1–C2 transarticular screw fixation for atlantoaxial instability
    Yongliang Yang
    Fu Wang
    Shumei Han
    Yonghui Wang
    Jinlei Dong
    Lianxin Li
    Dongsheng Zhou
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 1083 - 1092
  • [34] Computed Tomography-Based Feasibility Study of C1 Posterior Arch Crisscrossing Screw Fixation
    Sangondimath, Gururaj
    Mallepally, Abhinandan Reddy
    Salimath, Suman
    ASIAN SPINE JOURNAL, 2020, 14 (03) : 298 - 304
  • [35] Rod Migration into the Posterior Cranial Fossa after C1-C2-C3-C4 Screw Fixation: Case Report and Review of the Literature
    Basankin, Igor Vadimovich
    Porkhanov, Vladimir Alekseevich
    Giulzatyan, Abram Akopovich
    Nesterenko, Pavel Borisovich
    Khurshudyan, Eduard Romanovich
    Tomina, Marina Igorevna
    Gritsaev, Ivan Evgenievich
    Takhmazyan, Karapet Karapetovich
    Malakhov, Sergey Borisovich
    INDIAN JOURNAL OF NEUROSURGERY, 2024, 13 (01) : 73 - 75
  • [36] The dimensions of the posterior arch of C2 for instrumented screw fixation. A radiological study in the Spanish population
    Vazquez-Garcia, B.
    Villas, C.
    Pueyo, J.
    Broncano, J.
    Donat-Vargas, C.
    Alfonso, M.
    ANALES DEL SISTEMA SANITARIO DE NAVARRA, 2020, 43 (03) : 323 - 331
  • [37] Biomechanical comparison of a C1 posterior arch clamp with C1 lateral mass screws in constructs for C1-C2 fusion
    Lasswell, Timothy L.
    Medley, John B.
    Callaghan, Jack P.
    Cronin, Duane S.
    McKinnon, Colin D.
    Singh, Supriya
    Rasoulinejad, Parham
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2021, 235 (12) : 1463 - 1470
  • [38] Biomechanical Study of Horizontal Screw-screw Crosslink in C1-2 Pedicle Screw-rod Fixation
    Ouyang, Beiping
    Zou, Xiaobao
    Luo, Chunshan
    Lu, Tingsheng
    Ma, Xiangyang
    CLINICAL SPINE SURGERY, 2023, 36 (10): : E519 - E523
  • [39] Applied anatomy of a minimally invasive muscle-splitting approach to posterior C1-C2 fusion: an anatomical feasibility study
    Bodon, Gergely
    Lajos Patonay
    Baksa, Gabor
    Olerud, Claes
    SURGICAL AND RADIOLOGIC ANATOMY, 2014, 36 (10) : 1063 - 1069
  • [40] Disappearance of degenerative, non-inflammatory, retro-odontoid pseudotumor following posterior C1-C2 fixation: case series and review of the literature
    Barbagallo, Giuseppe M. V.
    Certo, Francesco
    Visocchi, Massimiliano
    Palmucci, Stefano
    Sciacca, Giovanni
    Albanese, Vincenzo
    EUROPEAN SPINE JOURNAL, 2013, 22 : S879 - S888