Filtered backprojection formula for exact image reconstruction from cone-beam data along a general scanning curve

被引:74
作者
Ye, YB
Wang, G
机构
[1] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Math, Iowa City, IA 52242 USA
关键词
cone-beam CT; filtered backprojection; image reconstruction; Katsevich formula; general scanning curve;
D O I
10.1118/1.1828673
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, Katsevich proved a filtered backprojection formula for exact image reconstruction from cone-beam data along a helical scanning locus, which is an important breakthrough since 1991 when the spiral cone-beam scanning mode was proposed. In this paper, we prove a generalized Katsevich's formula for exact image reconstruction from cone-beam data collected along a rather flexible curve. We will also give a general condition on filtering directions. Based on this condition, we suggest a natural choice of filtering directions, which is more convenient than Katsevich's choice and can be applied to general scanning curves. In the derivation, we use analytical techniques instead of geometric arguments. As a result, we do not need the uniqueness of the PI lines. In fact, our formula can be used to reconstruct images on any chord as long as a scanning curve runs from one endpoint of the chord to the other endpoint. This can be considered as a generalization of Orlov's classical theorem. Specifically, our formula can be applied to (i) nonstandard spirals of variable radii and pitches (with PI- or n-PI-windows), and (ii) saddlelike curves. (C) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:42 / 48
页数:7
相关论文
共 37 条
  • [31] Volume-of-Interest Reconstruction from Severely Truncated Data in Dental Cone-Beam CT
    Zhang, Zheng
    Kusnoto, Budi
    Han, Xiao
    Sidky, E. Y.
    Pan, Xiaochuan
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [32] A weighted rebinned backprojection-filtration algorithm from partially beam-blocked data for a single-scan cone-beam CT with hybrid type scatter correction
    Min, Jonghwan
    Pua, Rizza
    Kim, Changhwan
    Park, Miran
    Lee, Jongha
    Ye, Sung-Joon
    Cho, Seungryong
    MEDICAL PHYSICS, 2019, 46 (03) : 1182 - 1197
  • [33] Feldkamp-type VOI reconstruction from super-short-scan cone-beam data
    Yu, HY
    Wang, G
    MEDICAL PHYSICS, 2004, 31 (06) : 1357 - 1362
  • [34] Image reconstruction for cone-beam computed tomography using total p-variation plus Kullback-Leibler data divergence
    Cai, Ai-Long
    Li, Lei
    Wang, Lin-Yuan
    Yan, Bin
    Zheng, Zhi-Zhong
    Zhang, Han-Ming
    Hu, Guo-En
    CHINESE PHYSICS B, 2017, 26 (07)
  • [35] Image reconstruction for cone-beam computed tomography using total p-variation plus Kullback-Leibler data divergence
    蔡爱龙
    李磊
    王林元
    闫镔
    郑治中
    张瀚铭
    胡国恩
    Chinese Physics B, 2017, (07) : 465 - 477
  • [36] 3D Region-of-Interest (ROI) Reconstruction from Truncated Data in Circular Cone-beam CT
    Li, Liang
    Kang, Kejun
    Chen, Zhiqiang
    Zhang, Li
    Xing, Yuxiang
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4409 - 4412
  • [37] Technical Note: 4D cone-beam CT reconstruction from sparse-view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS-PT)
    den Otter, Lydia A.
    Chen, Kuanling
    Janssens, Guillaume
    Meijers, Arturs
    Both, Stefan
    Langendijk, Johannes A.
    Rosen, Lane R.
    Wu, Hsinshun T.
    Knopf, Antje-Christin
    MEDICAL PHYSICS, 2020, 47 (12) : 6381 - 6387