MEASURING ACTIVITY IN PATIENTS WITH SARCOIDOSIS - A PILOT TRIAL OF TWO WRIST-WORN ACCELEROMETER DEVICES

被引:0
作者
Atkins, Christopher P. [1 ,2 ]
Jones, Andy P. [1 ]
Wilson, Andrew M. [1 ,2 ]
机构
[1] Univ East Anglia, Norwich Med Sch, Norwich NR4 7TJ, Norfolk, England
[2] Norfolk & Norwich Univ Hosp, Colney Lane, Norwich NR4 7UQ, Norfolk, England
关键词
sarcoidosis; activity; accelerometers; PHYSICAL-ACTIVITY; SEDENTARY BEHAVIOR; UNITED-STATES; FATIGUE; FEATURES; TIME; HIP;
D O I
暂无
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Increasing physical activity is associated with health benefits. Reduced physical activity has been noted in sarcoidosis, particularly where fatigue co-exists. Monitoring physical activity is possible with wrist-worn devices. This study compared two available devices to determine patient preference and compare wear-time, with a secondary outcome of comparing device outputs with fatigue scores. Methods: Patients with sarcoidosis wore two wrist-worn activity monitors (GENEActiv actiwatch and Actigraph GT3X-bt) separately for seven days each. Participants were randomly allocated to receive either device first. Participants completed the Fatigue Assessment Scale (FAS) questionnaire immediately before wearing the first device. All participants completed a questionnaire of their perception regarding each device after the wear period. Data from the devices was analysed for total wear time, time spent in moderate or vigorous activity (MVPA) and for time spent in sedentary behaviours. Results: Twelve patients with sarcoidosis were included. The GENEActiv device was preferred by ten (83.3%) participants. Wear time was greater with the GENEActiv device (1354 minutes/day vs 1079 minutes/day). Time spent in MVPA was slightly higher when recorded by the GENEActiv compared with the Actigraph. Moderately strong correlation was seen between FAS scores and sedentary time (r=-0.554), light activity (r=-0.585) and moderate activity (r=0.506). Discussion: A clear preference was demonstrated for the GENEActiv. This was reflected in higher wear time and suggests the device can be comfortably worn 24 hours per day. Data from this small cohort also suggests there is correlation between fatigue and activity scores in patients with sarcoidosis.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 50 条
  • [31] Comparison of wrist-worn Fitbit Flex and waist-worn ActiGraph for measuring steps in free-living adults
    Chu, Anne H. Y.
    Ng, Sheryl H. X.
    Paknezhad, Mahsa
    Gauterin, Alvaro
    Koh, David
    Brown, Michael S.
    Muller-Riemenschneider, Falk
    PLOS ONE, 2017, 12 (02):
  • [32] Comparison of physical activity assessed using hip- and wrist-worn accelerometers
    Kamada, Masamitsu
    Shiroma, Eric J.
    Harris, Tamara B.
    Lee, I-Min
    GAIT & POSTURE, 2016, 44 : 23 - 28
  • [33] Comparison of the Wrist-Worn Fitbit Charge 2 and the Waist-Worn Actigraph GTX3 for Measuring Steps Taken in Occupational Settings
    Garza, Jennifer L.
    Wu, Zhao H.
    Singh, Manjot
    Cherniack, Martin G.
    ANNALS OF WORK EXPOSURES AND HEALTH, 2022, 66 (02) : 281 - 284
  • [34] Number of Days Required to Estimate Habitual Activity Using Wrist-Worn GENEActiv Accelerometer: A Cross-Sectional Study
    Dillon, Christina B.
    Fitzgerald, Anthony P.
    Kearney, Patricia M.
    Perry, Ivan J.
    Rennie, Kirsten L.
    Kozarski, Robert
    Phillips, Catherine M.
    PLOS ONE, 2016, 11 (05):
  • [35] Normative wrist-worn accelerometer values for self-paced walking and running: a walk in the park
    Dawkins, Nathan P.
    Yates, Tom
    Soczawa-Stronczyk, Artur A.
    Bocian, Mateusz
    Edwardson, Charlotte L.
    Maylor, Ben
    Davies, Melanie J.
    Khunti, Kamlesh
    Rowlands, Alex, V
    JOURNAL OF SPORTS SCIENCES, 2022, 40 (01) : 81 - 88
  • [36] Validation of a physical activity accelerometer device worn on the hip and wrist against polysomnography
    Full, Kelsie M.
    Kerr, Jacqueline
    Grandner, Michael A.
    Malhotra, Atul
    Moran, Kevin
    Godoble, Suneeta
    Natarajan, Loki
    Soler, Xavier
    SLEEP HEALTH, 2018, 4 (02) : 209 - 216
  • [37] Physische Aktivität bei älteren Menschen mit AugenerkrankungenAnwendbarkeit von ArmbandakzelerometernPhysical activity in older persons with eye diseasesApplicability of wrist-worn accelerometer
    M. Heinemann
    S. G. Welker
    F. G. Holz
    R. P. Finger
    Der Ophthalmologe, 2019, 116 (4): : 351 - 356
  • [38] Physical Activity Intensity Cut-Points for Wrist-Worn GENEActiv in Older Adults
    Fraysse, Francois
    Post, Dannielle
    Eston, Roger
    Kasai, Daiki
    Rowlands, Alex V.
    Parfitt, Gaynor
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2021, 2
  • [39] Separating Bedtime Rest from Activity Using Waist or Wrist-Worn Accelerometers in Youth
    Tracy, Dustin J.
    Xu, Zhiyi
    Choi, Leena
    Acra, Sari
    Chen, Kong Y.
    Buchowski, Maciej S.
    PLOS ONE, 2014, 9 (04):
  • [40] Validity of Wrist-Worn Activity Tracker Heart Rate Detection in Fontan Patients during Exercise
    Pierick, Alyson R.
    Burke, Kelly J.
    Prusi, Megan
    Largent, Bethany
    Yu, Sunkyung
    Lowery, Ray E.
    Duimstra, Ashley
    Hansen, Jesse E.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2025, 57 (02) : 280 - 284