Failure analysis of transmission line tower subjected to combined wind and dust loads

被引:2
作者
Salaam, Shaik Esub [1 ]
Rao, N. Prasad [2 ]
Raju, P. Krishnam [1 ]
机构
[1] Gayatri Vidya Parishad Coll Engn Autonomous, Dept Civil Engn, Visakhapatnam 530048, Andhra Pradesh, India
[2] CSIR Struct Engn Res Ctr, Chennai 600113, Tamil Nadu, India
来源
CURRENT SCIENCE | 2021年 / 121卷 / 04期
关键词
Dust storms; failure analysis; power supply; transmission line towers; COLLAPSE ANALYSIS; SYSTEM;
D O I
10.18520/cs/v121/i4/511-520
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Towers play a vital role in the transmission line (TL) system. The main objective of the present study is to analyse the failure of towers subjected to dust storms. This study, analyses the failure of a 765 kV single-circuit delta-type horizontal configuration tower in the river delta region near Agra. TL towers are designed based on IS 802 Part 1/Sec 1 and 2 standards. Dust particles of soil may be lighter individually, but have definite density. The wind carrying dust particles may increase the wind pressure on the tower line system. The increased wind pressure significantly affects the sag and tension of ground wire and conductor and results in additional loads on the tower, thus causing failure. It also increases wind load on the tower body and insulator string. There is literature related to numerical and wind tunnel studies on the combined effect of wind and rain loads, but no information is available on the wind and dust loads at present. The density variation method is used in the present study for calculation of additional wind pressure due to dust particles during storms. A relation between density of air mix, volume fraction of dust and density of dust particles is considered. Using FEM software, the tower is analysed for existing design loads and verified for its strength adequacy. The tower stability is studied by analysing for additional loads considering the presence of dust particles in the wind for three different volume fractions of 0.01%/m(3), 0.02%/m(3) and 0.03%/m(3). The wind pressure increases by about 10% for an increase of every 0.01% of dust particles in the wind. The tension in the conductor and ground wire increases by 8%. The existing tower design is inadequate to withstand the additional forces from wind storms associated even with a small fraction of dust particles and may be the reason for the failure of towers in northern India during a particular period of the year.
引用
收藏
页码:511 / 520
页数:10
相关论文
共 49 条
  • [31] Collapse analysis of a wind turbine tower with initial-imperfection subjected to near-field ground motions
    Xu, Yazhou
    Ren, Qianqian
    Zhang, Hui
    Shi, Wenhao
    STRUCTURES, 2021, 29 : 373 - 382
  • [32] Failure Analysis of Small Composite Sandwich Turbine Blade Subjected to Extreme Wind Load
    Chen, C. P.
    Kam, T. Y.
    PROCEEDINGS OF THE TWELFTH EAST ASIA-PACIFIC CONFERENCE ON STRUCTURAL ENGINEERING AND CONSTRUCTION (EASEC12), 2011, 14
  • [33] Structural failure analysis of a river-crossing transmission line impacted by the super typhoon Rammasun
    An, Liqiang
    Guan, Yongyu
    Zhu, Zhijian
    Wu, Jiong
    Zhang, Ronglun
    ENGINEERING FAILURE ANALYSIS, 2019, 104 : 911 - 931
  • [34] Seismic response and collapse analysis of a transmission tower-line system considering uncertainty factors
    Fu, Zhaoyang
    Tian, Li
    Liu, Juncai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 189
  • [35] Numerical and Experimental Failure Analysis of Steel Components in a High-Voltage Transmission Tower Structure
    Lashgari, H. R.
    Zangeneh, Sh.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2024, 24 (03) : 1030 - 1045
  • [36] Full-scale test and numerical failure analysis of a latticed steel tubular transmission tower
    Tian, Li
    Pan, Haiyang
    Ma, Ruisheng
    Zhang, Lijuan
    Liu, Zhengwei
    ENGINEERING STRUCTURES, 2020, 208
  • [37] Collapse and Pull - Down Analysis of High Voltage Electricity Transmission Towers Subjected to Cyclonic Wind
    Ahmed, Ammar
    Arthur, Craig
    Edwards, Mark
    9TH WORLD CONGRESS ON COMPUTATIONAL MECHANICS AND 4TH ASIAN PACIFIC CONGRESS ON COMPUTATIONAL MECHANICS, 2010, 10
  • [38] Wind-induced probabilistic failure analysis of super large cooling tower with random field properties
    Liang, Yan-Ping
    Ren, Xiaodan
    Feng, De-Cheng
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2023, 233
  • [39] Failure Analysis and Process Capability Study of Transmission System at the End of Assembly Line
    Panse, Aman
    Kane, Prasad, V
    RELIABILITY, SAFETY AND HAZARD ASSESSMENT FOR RISK-BASED TECHNOLOGIES, 2020, : 599 - 606
  • [40] Failure analysis and curvature-based failure criterion of super large cooling tower under strong equivalent static wind load
    Liang, Yan-Ping
    Ren, Xiaodan
    ENGINEERING FAILURE ANALYSIS, 2022, 142