A Novel Detector for 2D Ion Detection in Low-Pressure Gas and its Applications

被引:18
作者
Bashkirov, V. A. [1 ]
Hurley, R. F. [1 ]
Schulte, R. W.
机构
[1] Loma Linda Univ, Loma Linda, CA 92354 USA
来源
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2009年
关键词
D O I
10.1109/NSSMIC.2009.5402061
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A detector array for single-ion registration was developed and studied. The detector array was operated with various working gases, including propane, air, and water vapor at low gas pressure (a few mbar) in a limited Geiger mode, providing single ion sensitivity. The patterned detector structure, comprising sub-millimeter hole diameter, millimeter pitch, ground and 2D readout electrodes, were manufactured using standard PCB technology. A glass cathode was utilized to allow the limited discharge mode of operation. Essentially, the new detector is a combination of a hole-type micro-pattern detector and a resistive plate counter operating at reverse polarity in a low pressure gas. It was demonstrated that the unique combined properties of these well established individual detectors in the low pressure gas environment allows for single ion registration through ion-impact induced discharge confined inside an individual cell (hole) of the detector array. Possible applications of the new ion detector in gas chromatography - mass spectrometry and track structure imaging for radiation protection and hadron therapy are briefly discussed.
引用
收藏
页码:694 / 698
页数:5
相关论文
共 5 条
  • [1] BIRKINSHAW K, 2002, INT J MASS SPECTROME, V215
  • [2] Development of new hole-type avalanche detectors and the first results of their applications
    Charpak, G.
    Benaben, P.
    Breuil, P.
    Di Mauro, A.
    Martinengo, P.
    Peskov, V.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 1657 - 1663
  • [3] The performance of a novel ion-counting nanodosimeter
    Garty, G
    Shchemelinin, S
    Breskin, A
    Chechik, R
    Assaf, G
    Orion, I
    Bashkirov, V
    Schulte, R
    Grosswendt, B
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 492 (1-2) : 212 - 235
  • [4] On the physical origin of tails in the time response of spark counters
    Mangiarotti, A
    Gobbi, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 482 (1-2) : 192 - 215
  • [5] PAKA H, 1992, APPL PHYS, V71, P1