Wireless Power Transfer With Zero-Phase-Difference Capacitance Control

被引:21
作者
Iguchi, Shunta [1 ]
Yeon, Pyungwoo [1 ]
Fuketa, Hiroshi [1 ]
Ishida, Koichi [1 ,2 ]
Sakurai, Takayasu [1 ]
Takamiya, Makoto [1 ]
机构
[1] Univ Tokyo, Tokyo 1538505, Japan
[2] Tech Univ Dresden, D-01069 Dresden, Germany
关键词
Magnetic resonance; power amplifier; wireless power transmission; zero-phase-difference capacitance control; COUPLED RESONATORS; TRANSMISSION; ADAPTATION; DESIGN;
D O I
10.1109/TCSI.2015.2388832
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Wireless power transfer enables the frequent and ubiquitous charging of electronic devices. However, the variation of the efficiency and the received power with the transmission distance is an outstanding issue. To solve the problem of efficiency degradation of the magnetic resonance at short distances, zero-phase-difference capacitance control (ZPDCC), which is suitable for integration in large scale integrations (LSIs) is proposed in this paper. The proposed ZPDCC achieves adaptive capacitance control by a newly proposed control algorithm with a current-sensing circuit to control variable capacitors at a fixed frequency. Additionally, a theoretical analysis of the total DC-DC power transmission efficiency including a power amplifier, coupled resonators, and a rectifier is demonstrated in this paper. The analysis indicates that the frequency (and capacitance) splitting of is mainly due to the power amplifier; additionally, the efficiency of the power amplifier is maximized at the split peaks when the transmission distance is short. A wireless power transfer system in magnetic resonance with ZPDCC is fabricated in a 3.3 V, 180 nm CMOS. By introducing ZPDCC, the measured at 13.56 MHz increases 1.7 times from 16% to 27% at d = 2.5 mm.
引用
收藏
页码:938 / 947
页数:10
相关论文
共 30 条
[1]   Wireless Power Transmission With Self-Regulated Output Voltage for Biomedical Implant [J].
Ahn, Dukju ;
Hong, Songcheol .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (05) :2225-2235
[2]   A Transmitter or a Receiver Consisting of Two Strongly Coupled Resonators for Enhanced Resonant Coupling in Wireless Power Transfer [J].
Ahn, Dukju ;
Hong, Songcheol .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (03) :1193-1203
[3]  
[Anonymous], FREQ ALL AM SAT SERV
[4]  
[Anonymous], WID ULTR LOW NOIS VO
[5]  
[Anonymous], VIRT MULT SIM SPECTR
[6]  
Awai I., 2012, 2012 IEEE MTT-S International Microwave Workshop Series on Innovative Wireless Power Transmission: Technologies, Systems, and Applications (IMWS 2012), P105, DOI 10.1109/IMWS.2012.6215770
[7]   Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems [J].
Baker, Michael W. ;
Sarpeshkar, Rahul .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2007, 1 (01) :28-38
[8]   Automated Impedance Matching System for Robust Wireless Power Transfer via Magnetic Resonance Coupling [J].
Beh, Teck Chuan ;
Kato, Masaki ;
Imura, Takehiro ;
Oh, Sehoon ;
Hori, Yoichi .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (09) :3689-3698
[9]  
Brown W., P 1958 IRE INT CONV, P8, DOI [10.1109/IRECON.1964.1147324, DOI 10.1109/IRECON.1964.1147324]
[10]   Design and Optimization of a Class-E Amplifier for a Loosely Coupled Planar Wireless Power System [J].
Casanova, Joaquin J. ;
Low, Zhen Ning ;
Lin, Jenshan .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2009, 56 (11) :830-834