Predictors for the risk of permanent pacemaker implantation after transcatheter aortic valve replacement: A systematic review and meta-analysis

被引:9
|
作者
Wang, Tongyu [1 ]
Ou, Aixin [2 ]
Xia, Ping [1 ]
Tian, Jiahu [1 ]
Wang, Hongchang [3 ]
Cheng, Zeyi [4 ]
机构
[1] China Med Univ, Dept Cardiovasc Med, Affiliated Hosp 4, Shenyang, Liaoning, Peoples R China
[2] China Med Univ, Dept Radiol, Shengjing Hosp, Shenyang, Liaoning, Peoples R China
[3] Lanzhou Med Univ, Dept Emergency Med, Affiliated Hosp 1, Lanzhou 730030, Peoples R China
[4] Sichuan Univ, West China Hosp, Dept Cardiac Surg, Guoxue Alley, Chengdu 610041, Sichuan, Peoples R China
关键词
cardiac conduction abnormal; patient-prosthesis mismatch; surgical approach; valve implantation depth; valve selection; BUNDLE-BRANCH BLOCK; PROSTHESIS-PATIENT MISMATCH; CONDUCTION DISTURBANCES; MEDTRONIC COREVALVE; CLINICAL-OUTCOMES; EDWARDS SAPIEN; FOLLOW-UP; IMPACT; NEED; CALCIUM;
D O I
10.1111/jocs.16129
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transcatheter aortic valve replacement (TAVR) is a less invasive treatment than surgery for severe aortic stenosis. However, its use is restricted by the fact that many patients eventually require permanent pacemaker implantation (PPMI). This meta-analysis was performed to identify predictors of post-TAVR PPMI. Methods The PubMed, Embase, Web of Science, and Cochrane Library databases were systematically searched. Relevant studies that met the inclusion criteria were included in the pooling analysis after quality assessment. Results After pooling 67 studies on post-TAVR PPMI risk in 97,294 patients, balloon-expandable valve use was negatively correlated with PPMI risk compared with self-expandable valve (SEV) use (odds ratio [OR]: 0.44, 95% confidence interval [CI]: 0.37-0.53). Meta-regression analysis revealed that history of coronary artery bypass grafting and higher Society of Thoracic Surgeons (STS) risk score increased the risk of PPMI with SEV utilization. Patients with pre-existing cardiac conduction abnormalities in 28 pooled studies also had a higher risk of PPMI (OR: 2.33, 95% CI: 1.90-2.86). Right bundle branch block (OR: 5.2, 95% CI: 4.37-6.18) and first-degree atrioventricular block (OR: 1.97, 95% CI: 1.38-2.79) also increased PPMI risk. Although the trans-femoral approach was positively correlated with PPMI risk, the trans-apical pathway showed no statistical difference to the trans-femoral pathway. The approach did not increase PPMI risk in patients with STS scores >8. Patient-prosthesis mismatch did not influence post-TAVR PPMI risk (OR: 0.88, 95% CI: 0.67-1.16). We also analyzed implantation depth and found no difference between patients with PPMI after TAVR and those without. Conclusions SEV selection, pre-existing cardiac conduction abnormality, and trans-femoral pathway selection are positively correlated with PPMI after TAVR. Pre-existing left bundle branch block, patient-prosthesis mismatch, and implantation depth did not affect the risk of PPMI after TAVR.
引用
收藏
页码:377 / 405
页数:29
相关论文
共 50 条
  • [31] Predictors of ventricular pacing burden after permanent pacemaker implantation following transcatheter aortic valve replacement
    Elzeneini, Mohammed
    Assaf, Yazan
    Aalaei-Andabili, Seyed Hossein
    Mahmoud, Ahmad
    Hamburger, Robert
    Goel, Ramil
    Bavry, Anthony A.
    CLINICAL CARDIOLOGY, 2020, 43 (11) : 1334 - 1342
  • [32] Prognostic impact of permanent pacemaker implantation after transcatheter aortic valve replacement
    Sharobeem, Sam
    Boulmier, Dominique
    Leurent, Guillaume
    Bedossa, Marc
    Leclercq, Christophe
    Mabo, Philippe
    Martins, Raphael P.
    Tomasi, Jacques
    Verhoye, Jean-Philippe
    Donal, Erwan
    Sost, Gwenaelle
    Le Guellec, Marielle
    Le Breton, Herve
    Auffret, Vincent
    HEART RHYTHM, 2022, 19 (07) : 1124 - 1132
  • [33] A prediction model for permanent pacemaker implantation after transcatheter aortic valve replacement
    Qi, Yiming
    Lin, Xiaolei
    Pan, Wenzhi
    Zhang, Xiaochun
    Ding, Yuefan
    Chen, Shasha
    Zhang, Lei
    Zhou, Daxin
    Ge, Junbo
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2023, 28 (01)
  • [34] Incidence and determinants of permanent pacemaker implantation after transcatheter aortic valve replacement
    Bellantoni, Antonio
    Sorrentino, Sabato
    Boccuto, Fabiola
    Carabett, Nicole
    Giordano, Salvatore
    Cacia, Michele Antonio
    Polimeni, Alberto
    Leo, Isabella
    Varano, Ylenia
    Augusto, Florinda Maria
    Mongiardo, Annalisa
    De Rosa, Salvatore
    Indolfi, Ciro
    Spaccarotella, Carmen
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (SUPPL G)
  • [35] Reduction of permanent pacemaker implantation by using the cusp overlap technique in transcatheter aortic valve replacement: a meta-analysis
    Elias Rawish
    Sascha Macherey
    Dominik Jurczyk
    Toni Pätz
    John Jose
    Thomas Stiermaier
    Ingo Eitel
    Christian Frerker
    Tobias Schmidt
    Clinical Research in Cardiology, 2023, 112 : 633 - 644
  • [36] Incidence and determinants of permanent pacemaker implantation after transcatheter aortic valve replacement
    Bellantoni, Antonio
    Sorrentino, Sabato
    Boccuto, Fabiola
    Carabett, Nicole
    Giordano, Salvatore
    Cacia, Michele Antonio
    Polimeni, Alberto
    Leo, Isabella
    Varano, Ylenia
    Augusto, Florinda Maria
    Mongiardo, Annalisa
    De Rosa, Salvatore
    Indolfi, Ciro
    Spaccarotella, Carmen
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (0G) : G196 - G196
  • [37] Reduction of permanent pacemaker implantation by using the cusp overlap technique in transcatheter aortic valve replacement: a meta-analysis
    Rawish, Elias
    Macherey, Sascha
    Jurczyk, Dominik
    Paetz, Toni
    Jose, John
    Stiermaier, Thomas
    Eitel, Ingo
    Frerker, Christian
    Schmidt, Tobias
    CLINICAL RESEARCH IN CARDIOLOGY, 2023, 112 (05) : 633 - 644
  • [38] Permanent Pacemaker Implantation after Transcatheter Aortic Valve Replacement - National Experience
    Dhoble, Abhijeet
    Bhise, Viraj
    Balan, Prakash
    Nguyen, Tuyen C.
    Loyalka, Pranav
    Kar, Biswajit
    Smalling, Richard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B293 - B293
  • [39] Quality Control for Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement
    Yazdchi, Farhang
    Hirji, Sameer
    Kaneko, Tsuyoshi
    ANNALS OF THORACIC SURGERY, 2020, 110 (01): : 347 - 348
  • [40] A prediction model for permanent pacemaker implantation after transcatheter aortic valve replacement
    Yiming Qi
    Xiaolei Lin
    Wenzhi Pan
    Xiaochun Zhang
    Yuefan Ding
    Shasha Chen
    Lei Zhang
    Daxin Zhou
    Junbo Ge
    European Journal of Medical Research, 28