Predictors for the risk of permanent pacemaker implantation after transcatheter aortic valve replacement: A systematic review and meta-analysis

被引:9
作者
Wang, Tongyu [1 ]
Ou, Aixin [2 ]
Xia, Ping [1 ]
Tian, Jiahu [1 ]
Wang, Hongchang [3 ]
Cheng, Zeyi [4 ]
机构
[1] China Med Univ, Dept Cardiovasc Med, Affiliated Hosp 4, Shenyang, Liaoning, Peoples R China
[2] China Med Univ, Dept Radiol, Shengjing Hosp, Shenyang, Liaoning, Peoples R China
[3] Lanzhou Med Univ, Dept Emergency Med, Affiliated Hosp 1, Lanzhou 730030, Peoples R China
[4] Sichuan Univ, West China Hosp, Dept Cardiac Surg, Guoxue Alley, Chengdu 610041, Sichuan, Peoples R China
关键词
cardiac conduction abnormal; patient-prosthesis mismatch; surgical approach; valve implantation depth; valve selection; BUNDLE-BRANCH BLOCK; PROSTHESIS-PATIENT MISMATCH; CONDUCTION DISTURBANCES; MEDTRONIC COREVALVE; CLINICAL-OUTCOMES; EDWARDS SAPIEN; FOLLOW-UP; IMPACT; NEED; CALCIUM;
D O I
10.1111/jocs.16129
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transcatheter aortic valve replacement (TAVR) is a less invasive treatment than surgery for severe aortic stenosis. However, its use is restricted by the fact that many patients eventually require permanent pacemaker implantation (PPMI). This meta-analysis was performed to identify predictors of post-TAVR PPMI. Methods The PubMed, Embase, Web of Science, and Cochrane Library databases were systematically searched. Relevant studies that met the inclusion criteria were included in the pooling analysis after quality assessment. Results After pooling 67 studies on post-TAVR PPMI risk in 97,294 patients, balloon-expandable valve use was negatively correlated with PPMI risk compared with self-expandable valve (SEV) use (odds ratio [OR]: 0.44, 95% confidence interval [CI]: 0.37-0.53). Meta-regression analysis revealed that history of coronary artery bypass grafting and higher Society of Thoracic Surgeons (STS) risk score increased the risk of PPMI with SEV utilization. Patients with pre-existing cardiac conduction abnormalities in 28 pooled studies also had a higher risk of PPMI (OR: 2.33, 95% CI: 1.90-2.86). Right bundle branch block (OR: 5.2, 95% CI: 4.37-6.18) and first-degree atrioventricular block (OR: 1.97, 95% CI: 1.38-2.79) also increased PPMI risk. Although the trans-femoral approach was positively correlated with PPMI risk, the trans-apical pathway showed no statistical difference to the trans-femoral pathway. The approach did not increase PPMI risk in patients with STS scores >8. Patient-prosthesis mismatch did not influence post-TAVR PPMI risk (OR: 0.88, 95% CI: 0.67-1.16). We also analyzed implantation depth and found no difference between patients with PPMI after TAVR and those without. Conclusions SEV selection, pre-existing cardiac conduction abnormality, and trans-femoral pathway selection are positively correlated with PPMI after TAVR. Pre-existing left bundle branch block, patient-prosthesis mismatch, and implantation depth did not affect the risk of PPMI after TAVR.
引用
收藏
页码:377 / 405
页数:29
相关论文
共 108 条
  • [1] Comparison of Balloon-Expandable vs Self-expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement The CHOICE Randomized Clinical Trial
    Abdel-Wahab, Mohamed
    Mehilli, Julinda
    Frerker, Christian
    Neumann, Franz-Josef
    Kurz, Thomas
    Toelg, Ralph
    Zachow, Dirk
    Guerra, Elena
    Massberg, Steffen
    Schaefer, Ulrich
    El-Mawardy, Mohamed
    Richardt, Gert
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (15): : 1503 - 1514
  • [2] Association Between Body Mass Index and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement (TAVR) with Edwards SAPIEN™ 3 TAVR Valves: A Single-Center Experience
    Ahmad, Mansoor
    Patel, Jay N.
    Loc, Brian L.
    Vipparthy, Sharath C.
    Divecha, Chirag
    Barzallo, Pablo X.
    Kim, Minchul
    Baman, Timir
    Barzallo, Marco
    Mungee, Sudhir
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (07)
  • [3] The influence of native aortic valve calcium and transcatheter valve oversize on the need for pacemaker implantation after transcatheter aortic valve insertion
    Al-Azzam, Fu'ad
    Greason, Kevin L.
    Krittanawong, Chayakrit
    Williamson, Eric E.
    McLeod, Christopher J.
    King, Katherine S.
    Mathew, Verghese
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (05) : 1056 - +
  • [4] Usefulness of membranous septum length in the prediction of major conduction disturbances in patients undergoing transcatheter aortic valve replacement with different devices
    Aslan, Serkan
    Demir, Ali R.
    Celik, Omer
    Kalkan, Ali K.
    Uzun, Fatih
    Guner, Ahmet
    Topel, Cagdas
    Erturk, Mehmet
    [J]. KARDIOLOGIA POLSKA, 2020, 78 (10) : 1020 - 1028
  • [5] Conduction Disturbances After Transcatheter Aortic Valve Replacement Current Status and Future Perspectives
    Auffret, Vincent
    Puri, Rishi
    Urena, Marina
    Chamandi, Chekrallah
    Rodriguez-Gabella, Tania
    Philippon, Francois
    Rodes-Cabau, Josep
    [J]. CIRCULATION, 2017, 136 (11) : 1049 - +
  • [6] Clinical Impact of Baseline Right Bundle Branch Block in Patients Undergoing Transcatheter Aortic Valve Replacement
    Auffret, Vincent
    Webb, John G.
    Eltchaninoff, Helene
    Munoz-Garcia, Antonio J.
    Himbert, Dominique
    Tamburino, Corrado
    Nombela-Franco, Luis
    Nietlispach, Fabian
    Moris, Cesar
    Ruel, Marc
    Dager, Antonio E.
    Serra, Vicenc
    Cheema, Asim N.
    Amat-Santos, Ignacio J.
    de Brito, Fabio Sandoli, Jr.
    Lemos, Pedro Alves
    Abizaid, Alexandre
    Sarmento-Leite, Rogerio
    Dumont, Eric
    Barbanti, Marco
    Durand, Eric
    Alonso Briales, Juan H.
    Vahanian, Alec
    Bouleti, Claire
    Imme, Sebastiano
    Maisano, Francesco
    del Valle, Raquel
    Miguel Benitez, Luis
    Garcia del Blanco, Bruno
    Puri, Rishi
    Philippon, Francois
    Urena, Marina
    Rodes-Cabau, Josep
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (15) : 1564 - 1574
  • [7] Temporal Trends in Transcatheter Aortic Valve Replacement in France FRANCE 2 to FRANCE TAVI
    Auffret, Vincent
    Lefevre, Thierry
    Van Belle, Eric
    Eltchaninoff, Helene
    Iung, Bernard
    Koning, Rene
    Motreff, Pascal
    Leprince, Pascal
    Verhoye, Jean Philippe
    Manigold, Thibaut
    Souteyrand, Geraud
    Boulmier, Dominique
    Joly, Patrick
    Pinaud, Frederic
    Himbert, Dominique
    Collet, Jean Philippe
    Rioufol, Gilles
    Ghostine, Said
    Bar, Olivier
    Dibie, Alain
    Champagnac, Didier
    Leroux, Lionel
    Collet, Frederic
    Teiger, Emmanuel
    Darremont, Olivier
    Folliguet, Thierry
    Leclercq, Florence
    Lhermusier, Thibault
    Olhmann, Patrick
    Huret, Bruno
    Lorgis, Luc
    Drogoul, Laurent
    Bertrand, Bernard
    Spaulding, Christian
    Quilliet, Laurent
    Cuisset, Thomas
    Delomez, Maxence
    Beygui, Farzin
    Claudel, Jean-Philippe
    Hepp, Alain
    Jegou, Arnaud
    Gommeaux, Antoine
    Mirode, Anfani
    Christiaens, Luc
    Christophe, Charles
    Cassat, Claude
    Metz, Damien
    Mangin, Lionel
    Isaaz, Karl
    Jacquemin, Laurent
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (01) : 42 - 55
  • [8] Ball TN., 2018, P BAYL U MED CENT, V31, P1
  • [9] Aortoventricular annulus shape as a predictor of pacemaker implantation following transcatheter aortic valve replacement
    Barkagan, Michael
    Topilsky, Yan
    Steinvil, Arie
    Aviram, Galit
    Ben-Shoshan, Jeremy
    Finkelstein, Ariel
    Banai, Shmuel
    Keren, Gad
    Shmilovich, Haim
    [J]. JOURNAL OF CARDIOVASCULAR MEDICINE, 2017, 18 (06) : 425 - 429
  • [10] Multicentre propensity-matched comparison of transcatheter aortic valve implantation using the ACURATE TA/neo self-expanding versus the SAPIEN 3 balloon-expandable prosthesis
    Barth, Sebastian
    Reents, Wilko
    Zacher, Michael
    Kerber, Sebastian
    Diegeler, Anno
    Schieffer, Bernhard
    Schreiber, Matthias
    Lauer, Bernward
    Kuntze, Thomas
    Dahmer, Marko
    Hamm, Christian
    Hamm, Karsten
    [J]. EUROINTERVENTION, 2019, 15 (10) : 884 - +