Experimental and shear bearing capacity studies of the assembled composite wall with bolted connections

被引:20
|
作者
Huang, Wei [1 ]
Miao, Xinwei [1 ]
Hu, Gaoxing [1 ]
Fan, Zhenhui [1 ]
Zhang, Jiarui [1 ]
Ling, Ke [1 ]
机构
[1] Xian Univ Architecture & Technol, Coll Civil Engn, Xian 710055, Shaanxi, Peoples R China
关键词
assembled composite wall; bolted connection; monotonic loading; numerical analysis; seismic performance; shear bearing capacity; SEISMIC PERFORMANCE; PRECAST; BEHAVIOR; DESIGN;
D O I
10.1002/tal.1722
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To realize the dry connection of an assembled composite wall structure, a bolted connection based on the horizontal joint of an assembled composite wall is proposed. Five specimens were designed under monotonic loading. The failure modes, the seismic performance of the specimens, and the strains and slip of the connectors were studied. The plate thickness and the high-strength bolts diameter are the key points of research. Moreover, the finite element model for experiment is also established, and the parameters are analyzed based on the numerical models. The results of the experiments and the simulations show that the bolted connection is feasible and the specimens have good deformation capacity. Increasing the plate thickness can improve the bearing capacity of the specimens. Finally, the formula for the shear bearing capacity of the specimen is obtained.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Block shear failure planes of bolted connections - Direct experimental verifications
    Teh, Lip H.
    Uz, Mehmet E.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 111 : 70 - 74
  • [32] Block Shear Capacity of Bolted Connections in Cold-Reduced Steel Sheets
    Teh, Lip H.
    Clements, Drew D. A.
    JOURNAL OF STRUCTURAL ENGINEERING, 2012, 138 (04) : 459 - 467
  • [33] Shear capacity of additively manufactured stainless steel bolted connections after fire
    Kong, Zhengyi
    Li, Rui
    Wang, Xiaofei
    Hu, Ningning
    Jin, Ya
    Tao, Qinglin
    Vasdravellis, George
    ENGINEERING STRUCTURES, 2025, 322
  • [34] Seismic Performance Assessment of Bolt Connection-based Assembled Composite Shear-wall
    Yi Wang
    Zhaochen Wang
    Peibo You
    Jin Zhao
    Xuedong Hao
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2022, 46 : 3723 - 3737
  • [35] Experimental Study of Aluminium-Timber Composite Bolted Connections Strengthened with Toothed Plates
    Chybinski, Marcin
    Polus, Lukasz
    MATERIALS, 2022, 15 (15)
  • [36] Bearing factors for single shear bolted connections of thin sheet steels at elevated temperatures
    Yan, Shu
    Young, Ben
    THIN-WALLED STRUCTURES, 2012, 52 : 126 - 142
  • [37] Generalised component method for bolted bearing type connections incorporating block shear failure
    Zhou, Jingsheng
    Rasmussen, Kim J. R.
    Yan, Shen
    Deierlein, Gregory G.
    Zhang, Hao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 220
  • [38] New modular precast composite shear wall structural system and experimental study on its seismic performance
    Zhao, Bin
    Wu, Di
    Zhu, Huiqing
    ENGINEERING STRUCTURES, 2022, 264
  • [39] Calculation Method Research of Shear Bearing Capacity for Frame-sparse Gridiron Composite Wall
    Jiang Xufeng
    Guo Meng
    Wu Chenghao
    EMERGING MATERIALS AND MECHANICS APPLICATIONS, 2012, 487 : 232 - +
  • [40] Bearing capacity of bolted-mortar infill connections in bamboo and yield model formulation
    Correal, Juan F.
    Prada, Esteban
    Suarez, Ana
    Moreno, Daniela
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 305