Experimental and shear bearing capacity studies of the assembled composite wall with bolted connections

被引:20
|
作者
Huang, Wei [1 ]
Miao, Xinwei [1 ]
Hu, Gaoxing [1 ]
Fan, Zhenhui [1 ]
Zhang, Jiarui [1 ]
Ling, Ke [1 ]
机构
[1] Xian Univ Architecture & Technol, Coll Civil Engn, Xian 710055, Shaanxi, Peoples R China
关键词
assembled composite wall; bolted connection; monotonic loading; numerical analysis; seismic performance; shear bearing capacity; SEISMIC PERFORMANCE; PRECAST; BEHAVIOR; DESIGN;
D O I
10.1002/tal.1722
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To realize the dry connection of an assembled composite wall structure, a bolted connection based on the horizontal joint of an assembled composite wall is proposed. Five specimens were designed under monotonic loading. The failure modes, the seismic performance of the specimens, and the strains and slip of the connectors were studied. The plate thickness and the high-strength bolts diameter are the key points of research. Moreover, the finite element model for experiment is also established, and the parameters are analyzed based on the numerical models. The results of the experiments and the simulations show that the bolted connection is feasible and the specimens have good deformation capacity. Increasing the plate thickness can improve the bearing capacity of the specimens. Finally, the formula for the shear bearing capacity of the specimen is obtained.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Experimental and numerical investigations of aluminium-timber composite beams with bolted connections
    Chybinski, Marcin
    Polus, Lukasz
    STRUCTURES, 2021, 34 : 1942 - 1960
  • [22] Experimental study on seismic behavior of composite coupling beams in assembled hollow panel shear wall structure
    Qian J.
    Cui Y.
    Zhang W.
    Han W.
    Ma T.
    Zhang Y.
    Zhang Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (01): : 51 - 60
  • [23] BOLTED CONNECTIONS SUBJECT TO SHEAR-OUT OR COMBINED BEARING AND SHEAR-OUT FAILURES
    Teh, Lip H.
    Uz, Mehmet E.
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [24] Failure Modes and Bearing Capacity of High-Strength-Steel-Bearing-Type Bolted Connections
    Di, Jin
    Xiao, Bowen
    Li, Yongqing
    Su, Yi
    Zhang, Qian
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (03)
  • [25] Predicting bearing capacity of angle steel bolted connections using machine learning based on experimental and numerical database
    Li, Xiongyan
    Liu, Caibao
    Xue, Yu
    Xue, Suduo
    Liao, Song
    Zhou, Yang
    STRUCTURES, 2024, 67
  • [26] Experimental study on seismic behavior of steel plate shear wall with high load-bearing capacity
    Cui J.
    Huo T.
    Xu J.
    Xu Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (05): : 79 - 88
  • [27] Experimental and numerical study on reduction coefficient of the shear capacity of austenitic long stainless-steel bolted connections
    Zhao, Jun
    Wang, Zhuang
    Peng, Yang
    Liu, Xuan
    Dong, Jun
    ENGINEERING STRUCTURES, 2022, 267
  • [28] Shear bearing capacity calculation of low-rise SFRC shear wall with CFST columns based on simplified softened strut and tie model
    You, Peibo
    Li, Li
    Qin, Yapeng
    Wang, Yi
    Yang, Qingjie
    Zhang, Jie
    FRONTIERS IN MATERIALS, 2024, 10
  • [29] Bearing factors of cold-formed stainless steel double shear bolted connections at elevated temperatures
    Cai, Yancheng
    Young, Ben
    THIN-WALLED STRUCTURES, 2016, 98 : 212 - 229
  • [30] Experimental and numerical study of undersized shear panel dampers with bolted connections
    Zhao, Huatian
    Shi, Gang
    Li, Shuailing
    Zhang, Naizhou
    Zhuang, Shanxiang
    Zhu, Bin
    ENGINEERING STRUCTURES, 2023, 280