Ultrasound-guided fine-needle aspiration versus fine-needle capillary sampling biopsy of thyroid nodules - Does technique matter?

被引:41
作者
Tublin, Mitchell E. [1 ]
Martin, Joseph A. [1 ]
Rollin, Lori J. [1 ]
Pealer, Karen [1 ]
Kurs-Lasky, Marcia [3 ]
Ohori, N. Paul [2 ]
机构
[1] Univ Pittsburgh, Med Ctr, Dept Radiol, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Med Ctr, Dept Pathol, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh, Grad Sch Publ Hlth, Dept Biostat, Pittsburgh, PA 15213 USA
关键词
biopsy; thyroid; ultrasound;
D O I
10.7863/jum.2007.26.12.1697
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. Both fine-needle aspiration (FNA) and fine-needle capillary (FNC) sampling of palpable thyroid nodules have been advocated. The appropriate technique for biopsy of nonpalpable nodules now sampled under ultrasound guidance has not been assessed. The objective of this study was to determine cytologic adequacy rates of ultrasound-guided FNA and FNC sampling. Methods. Ultrasound-guided fine-needle biopsy was performed on 180 thyroid nodules. Nodules were measured and characterized (mixed cystic-solid or solid) on diagnostic sonography The technique used for biopsy (FNA versus FNC sampling) alternated sequentially per patient. Four 25-gauge fine-needle samples were obtained from each nodule. The sampling adequacy and cytopathologic diagnoses were recorded. The significance of differences in cytologic adequacy rates between techniques was then assessed with a repeated measures logistic regression model. Results. Fine-needle aspiration and FNC sampling biopsies were performed in 88 and 92 nodules, respectively Fine-needle aspiration was diagnostic (ie, satisfactory) in 78 (89%) of 88 nodules and nondiagnostic (less than optimal or unsatisfactory) in 10 (11 %) of 88 nodules; FNC sampling was diagnostic in 80 (87%) of 92 nodules and nondiagnostic in 12 (13%) of 92 nodules. Fine-needle aspiration sampling was diagnostic in 38 (86%) of 44 solid nodules and 40 (91 %) of 44 mixed cystic-solid nodules; FNC sampling was diagnostic in 48 (81 %) of 59 solid nodules and 32 (97%) of 33 mixed cystic-solid nodules. These percentages were not significantly different. Conclusions. Ultrasound-guided FNA and FNC sampling result in comparable diagnostic cytologic adequacy rates. Equivalent diagnostic yields and the technical ease of capillary sampling may prompt adoption of FNC sampling at high-volume endocrine/radiology practices.
引用
收藏
页码:1697 / 1701
页数:5
相关论文
共 50 条
[31]   Carotid intramural hematoma after ultrasound-guided fine-needle aspiration biopsy [J].
Qin, Xiaojuan ;
Deng, Yao .
ASIAN JOURNAL OF SURGERY, 2023, 46 (06) :2542-2543
[32]   Pain associated with fine-needle aspiration biopsy of thyroid nodules [J].
Stangierski, Adam ;
Ruchala, Marek ;
Warmuz-Stangierska, Izabela ;
Glowacka, Maria Danuta ;
Zdanowska, Joanna ;
Glowacka-Rebala, Alicja ;
Rasinska, Renata ;
Czarnywojtek, Agata .
PRZEGLAD MENOPAUZALNY, 2012, 11 (03) :233-238
[33]   Ultrasound-Guided Fine-Needle Aspiration Practice Patterns [J].
Heller, Howard T. ;
Cibas, Edmund S. ;
Kraft, Adele O. ;
Jiang, Xiaoyin Sara ;
Foo, Wen-Chi ;
Sanchez, Miguel A. ;
Powers, Celeste N. .
AJSP-REVIEWS AND REPORTS, 2018, 23 (04) :159-164
[34]   Comparison of cytological adequacy in ultrasound-guided fine-needle aspiration of thyroid nodules with different numbers of needle passes [J].
Chen, Q. -Y. ;
Zhang, T. ;
LI, W. -G. ;
Liang, M. -L. ;
LI, C. -Z. ;
Song, D. -D. ;
LI, Z. -F. ;
Pan, D. -Y. ;
Hu, S. -D. ;
Song, Y. -Q. ;
Chen, Z. .
EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (13) :6000-6005
[35]   Thyroid nodules with initially non-diagnostic, fine-needle aspiration results: comparison of core-needle biopsy and repeated fine-needle aspiration [J].
Sang Hyun Choi ;
Jung Hwan Baek ;
Jeong Hyun Lee ;
Young Jun Choi ;
Min Ji Hong ;
Dong Eun Song ;
Jae Kyun Kim ;
Jong Ho Yoon ;
Won Bae Kim .
European Radiology, 2014, 24 :2819-2826
[36]   How to do it: ultrasound-guided fine-needle aspiration of thyroid nodules that commonly result in inappropriate cytology [J].
Kim, Dong Wook .
CLINICAL IMAGING, 2013, 37 (01) :1-7
[37]   Thyroid nodules with initially non-diagnostic, fine-needle aspiration results: comparison of core-needle biopsy and repeated fine-needle aspiration [J].
Choi, Sang Hyun ;
Baek, Jung Hwan ;
Lee, Jeong Hyun ;
Choi, Young Jun ;
Hong, Min Ji ;
Song, Dong Eun ;
Kim, Jae Kyun ;
Yoon, Jong Ho ;
Kim, Won Bae .
EUROPEAN RADIOLOGY, 2014, 24 (11) :2819-2826
[38]   Fine-Needle Aspiration Cytology of Thyroid Nodule: Does the Needle Matter? [J].
Cappelli, Carlo ;
Pirola, Ilenia ;
Gandossi, Elena ;
De Martino, Elena ;
Agosti, Barbara ;
Castellano, Maurizio .
SOUTHERN MEDICAL JOURNAL, 2009, 102 (05) :498-501
[39]   Diagnostic Accuracy of Surgeon-Performed Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules [J].
Bohacek, Linda ;
Milas, Mira ;
Mitchell, Jamie ;
Siperstein, Allan ;
Berber, Eren .
ANNALS OF SURGICAL ONCOLOGY, 2012, 19 (01) :45-51
[40]   Does Tumor Size Influence the Diagnostic Accuracy of Ultrasound-Guided Fine-Needle Aspiration Cytology for Thyroid Nodules? [J].
Koo, Do Hoon ;
Song, KwangSeop ;
Kwon, Hyungju ;
Bae, Dong Sik ;
Kim, Ji-hoon ;
Min, Hye Sook ;
Lee, Kyu Eun ;
Youn, Yeo-Kyu .
INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2016, 2016