Treatment of Gastrocnemius Muscle Hypertrophy with Botulinum Toxin Injection Followed by Magnetic Resonance Imaging Assessment and 3-Dimensional Evaluation

被引:23
|
作者
Bogari, Melia [1 ]
Tan, Andy [1 ]
Xin, Yu [1 ]
Chai, Gang [1 ]
Lin, Li [1 ]
Min, Peiru [1 ]
Zhang, Yan [1 ]
Zhang, Yixin [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Dept Plast & Reconstruct Surg, 639 Zhi Zao Ju Rd, Shanghai 200011, Peoples R China
基金
中国国家自然科学基金;
关键词
SELECTIVE NEURECTOMY; CALF HYPERTROPHY; ASIANS; CALVES; RESECTION; NERVE;
D O I
10.1093/asj/sjx070
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Hypertrophy of the gastrocnemius muscle is considered to be a hindrance to lower leg beauty in the Asian aesthetic market. A noninvasive technique that has been gaining recognition involves botulinum toxin A injection; however, there are no proper guidelines or standardized protocols for the administration of botulinum toxin to correct gastrocnemius hypertrophy. Objectives: This study sought to determine the most effective botulinum toxin injection method for correcting the contour of the lower leg calf, as well as to determine the dose that can produce the maximum effect in meeting the demands of the physician and patient. Methods: Eighteen female patients aged between 18 and 35 years were enrolled in this study from January 2015 to July 2015. Two injection methods were compared: (I) 48 injection points with a distance of 2 cm between every point; and (II) 10 injection points. Magnetic resonance imaging examinations were conducted at baseline prior to treatment and at one month and 6 months after treatment. A 3-dimensional study was performed to analyze the volumetric changes. Results: The most effective and significant treatment method for hypertrophic gastrocnemius muscle was the 48-point method (scattering injection). Following injection, this method exhibited a significant level of satisfaction with outcome. Conclusions: Our study reveals that injection dosage and method have a strong relationship with achieving a better contouring result.
引用
收藏
页码:1146 / 1156
页数:11
相关论文
共 50 条
  • [41] OPTIMAL IMAGING STRATEGIES FOR 3-DIMENSIONAL NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY
    AHN, CB
    CHU, WC
    JOURNAL OF MAGNETIC RESONANCE, 1991, 94 (03): : 455 - 470
  • [42] Complications After Liver Transplantation: Evaluation With Magnetic Resonance Imaging, Magnetic Resonance Cholangiography, and 3-Dimensional Contrast-Enhanced Magnetic Resonance Angiography in a Single Session
    Boraschi, Piero
    Donati, Francescamaria
    Gigoni, Roberto
    Salemi, Simonetta
    Urbani, Lucio
    Filipponi, Franco
    Falaschi, Fabio
    Bartolozzi, Carlo
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2008, 59 (05): : 259 - 263
  • [43] Definition of a Stereotactic 3-Dimensional Magnetic Resonance Imaging Template of the Human Insula
    Afif, Afif
    Becq, Guillaume
    Mertens, Patrick
    NEUROSURGERY, 2013, 72 : 35 - 46
  • [44] Prenatal Diagnosis of Seckel Syndrome on 3-Dimensional Sonography and Magnetic Resonance Imaging
    Napolitano, Raffaele
    Maruotti, Giuseppe M.
    Quarantelli, Mario
    Martinelli, Pasquale
    Paladini, Dario
    JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (03) : 369 - 374
  • [45] Magnetic resonance imaging and 3-dimensional analysis of external anal sphincter anatomy
    Hsu, Y
    Fenner, DE
    Weadock, WJ
    DeLancey, JOL
    OBSTETRICS AND GYNECOLOGY, 2005, 106 (06): : 1259 - 1265
  • [46] ARTIFACTS DUE TO RESIDUAL MAGNETIZATION IN 3-DIMENSIONAL MAGNETIC-RESONANCE IMAGING
    WOOD, ML
    RUNGE, VM
    MEDICAL PHYSICS, 1988, 15 (06) : 825 - 831
  • [47] Evaluation of 3-Dimensional Magnetic Resonance Imaging (3D MRI) in Diagnosing Anterior Talofibular Ligament Injury
    Xu, Yan
    He, Lei
    Han, Yu
    Duan, Deyu
    Ouyang, Liu
    MEDICAL SCIENCE MONITOR, 2021, 27
  • [48] Magnetic Resonance Imaging Versus 3-Dimensional Laser Scanning for Breast Volume Assessment After Breast Reconstruction
    Howes, Benjamin H. L.
    Watson, David I.
    Fosh, Beverley
    Yip, Jia Miin
    Kleinig, Pakan
    Dean, Nicola Ruth
    ANNALS OF PLASTIC SURGERY, 2017, 78 (04) : 455 - 459
  • [49] Magnetic Resonance Imaging Versus 3-Dimensional Laser Scanning for Breast Volume Assessment After Breast Reconstruction
    Wang, Chenglong
    Luan, Jie
    ANNALS OF PLASTIC SURGERY, 2018, 80 (05) : 592 - 592
  • [50] Commentary on Effect of a Second Injection of Botulinum Toxin on Lower Facial Contouring, as Evaluated Using 3-Dimensional Laser Scanning
    Park, Mee Young
    Ahn, Ki Young
    DERMATOLOGIC SURGERY, 2015, 41 (04) : 445 - 446