Improved understanding of factors contributing to quantification of anhydrate/hydrate powder mixtures

被引:61
作者
Rantanen, J
Wikström, H
Rhea, FE
Taylor, LS [1 ]
机构
[1] Purdue Univ, Dept Ind & Phys Pharm, W Lafayette, IN 47907 USA
[2] Univ Helsinki, Viikki Drug Discovery Technol Ctr, Pharmaceut Technol Div, FIN-00014 Helsinki, Finland
关键词
chemometrics; multivariate data analysis; process analytical technology; PAT; near infrared; NIR; Raman; spectroscopy; quantitation;
D O I
10.1366/0003702054411670
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Different spectroscopic approaches have proved to be excellent analytical tools for monitoring process-induced transformations of active pharmaceutical ingredients during pharmaceutical unit operations. In order to use these tools effectively, it is necessary to build calibration models that describe the relationship between the amount of each solid-state form of interest and the spectroscopic signal. In this study, near-infrared (NIR) and Raman spectroscopic methods have been evaluated for the quantification of hydrate and anhydrate forms in pharmaceutical powders. Process type spectrometers were used to collect the data and the role of the sampling procedure was examined. Multivariate regression models were compared with traditional univariate calibrations and special emphasis was placed on data treatment prior to multivariate modeling by partial least squares (PLS). It was found that the measured sample volume greatly affected the performance of the model whereby the calibrations were significantly improved by utilizing a larger sampling area. In addition, multivariate regression did not always improve the predictability of the data compared to univariate analysis. The data treatment prior to multivariate modeling had a significant influence on the quality of predictions with standard normal variate transformation generally proving to be the best preprocessing method. When the appropriate sampling techniques and data analysis methods were utilized, both NIR and Raman spectroscopy were found to be suitable methods for the quantification of anhydrate/hydrate in powder systems, and thus the method of choice will depend on the conditions in the process under investigation.
引用
收藏
页码:942 / 951
页数:10
相关论文
共 41 条
[1]   An introduction to wavelet transforms for chemometricians: A time-frequency approach [J].
Alsberg, BK ;
Woodward, AM ;
Kell, DB .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 37 (02) :215-239
[2]   Monitoring of a film coating process for tablets using near infrared reflectance spectrometry [J].
Andersson, M ;
Josefson, M ;
Langkilde, FW ;
Wahlund, KG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) :27-37
[3]   Study of preprocessing methods for the determination of crystalline phases in binary mixtures of drug substances by X-ray powder diffraction and multivariate calibration [J].
Artursson, T ;
Hagman, A ;
Björk, S ;
Trygg, J ;
Wold, S ;
Jacobsson, SP .
APPLIED SPECTROSCOPY, 2000, 54 (08) :1222-1230
[4]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[5]   Effective sample size in diffuse reflectance near-IR spectrometry [J].
Berntsson, O ;
Burger, T ;
Folestad, S ;
Danielsson, LG ;
Kuhn, J ;
Fricke, J .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :617-623
[6]   Near-infrared spectroscopy in the pharmaceutical industry [J].
Blanco, M ;
Coello, J ;
Iturriaga, H ;
Maspoch, S ;
de la Pezuela, C .
ANALYST, 1998, 123 (08) :135R-150R
[7]   Quantitation of cefepime center dot 2HCl dihydrate in cefepime center dot 2HCl monohydrate by diffuse reflectance IR and powder X-ray diffraction techniques [J].
Bugay, DE ;
Newman, AW ;
Findlay, WP .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 15 (01) :49-61
[8]   Determination of the information depth and sample size for the analysis of pharmaceutical materials using reflectance near-infrared microscopy [J].
Clarke, FC ;
Hammond, SV ;
Jee, RD ;
Moffat, AC .
APPLIED SPECTROSCOPY, 2002, 56 (11) :1475-1483
[9]   A COMPARISON OF FOURIER-TRANSFORM INFRARED AND NEAR-INFRARED FOURIER-TRANSFORM RAMAN-SPECTROSCOPY FOR QUANTITATIVE MEASUREMENTS - AN APPLICATION IN POLYMORPHISM [J].
DEELEY, CM ;
SPRAGG, RA ;
THRELFALL, TL .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1991, 47 (9-10) :1217-1223
[10]   ON THE SCALES ASSOCIATED WITH NEAR-INFRARED REFLECTANCE DIFFERENCE SPECTRA [J].
DHANOA, MS ;
LISTER, SJ ;
BARNES, RJ .
APPLIED SPECTROSCOPY, 1995, 49 (06) :765-772