Turn-on ratiometric fluorescence sensor film for ammonia based on salicylaldehyde-ionic liquid

被引:17
作者
Ali, Reham [1 ]
Elshaarawy, Reda F. M. [1 ,2 ]
Saleh, Sayed M. [3 ]
机构
[1] Suez Univ, Fac Sci, Chem Dept, Suez 43518, Egypt
[2] Heinrich Heine Univ, Inst Anorgan Chem & Strukturchem, D-40204 Dusseldorf, Germany
[3] Suez Univ, Fac Petr & Min Engn, Chem Branch, Dept Sci & Math, Suez 43721, Egypt
来源
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING | 2017年 / 5卷 / 05期
关键词
Ammonia; Sensor film; Ionic liquid; Ratiometric sensor; MATRIX; PROBE; DYES;
D O I
10.1016/j.jece.2017.09.022
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
We developed a novel and highly optical sensitive ammonia sensor film with merits including fluorescence turnon, ratiometric measurements and large Stocks shift. The film was designed based on the incorporation of pH probe methylimidazolium salicylaldehyde ionic liquid (MeIm-Sal-IL) and a reference pH insensitive dye mesotetrakis( pentafluorophenyl) porphyrin (TFPP) in commercial polystyrene (PS) matrix. The pH probe provides dual solubility, large Stocks shift and fluorescence turn on in basic medium over other pH fluorophores; that makes it promising candidate for the development of a new ammonia sensor film. All homogeneous components are dissolved in a single film then spread on an optically inert transparent polyester support. PS displays a good permeability for ammonia and inhibits protons penetrations that make the sensor film insensitive to pH changes outside the matrix. As ammonia penetrate the PS matrix it converts the doped pH probe MeIm-Sal-IL from protonated form to deprotonated form inducing large spectroscopic changes in both absorption and fluorescence as turn-on obviously occurs in fluorescence. The new film measures the ammonia in moderate low concentration from 0.5 up to 2.5 mu M with a low limit of detection (LOD) 0.07 mu M. The sensor film exhibits high reversibility by cycling between ammonia and water.
引用
收藏
页码:4813 / 4818
页数:6
相关论文
共 50 条
  • [41] Design of "turn-on" fluorescence sensor for L-Cysteine based on the instability of metal-organic frameworks
    Zhao, Xudong
    Zhang, Yuezhong
    Han, Jiamei
    Jing, Huimin
    Gao, Zhuqing
    Huang, Hongliang
    Wang, Yuanyang
    Zhong, Chongli
    MICROPOROUS AND MESOPOROUS MATERIALS, 2018, 268 : 88 - 92
  • [42] A highly selective fluorescence "turn-on" sensor for Ca2+ based on diarylethene with a triazozoyl hydrazine unit
    Wang, Zhen
    Cui, Shiqiang
    Qiu, Shouyu
    Pu, Shouzhi
    RSC ADVANCES, 2018, 8 (51): : 29295 - 29300
  • [43] Highly selective fluorescence turn-on sensor for hydrogen sulfide and imaging in living cells
    Wang, Jiaoliang
    Long, Liping
    Xie, Dan
    Zhan, Youwen
    JOURNAL OF LUMINESCENCE, 2013, 139 : 40 - 46
  • [44] Ratiometric Optical Temperature Sensor Using Two Fluorescent Dyes Dissolved in an Ionic Liquid Encapsulated by Parylene Film
    Kan, Tetsuo
    Aoki, Hironori
    Nguyen Binh-Khiem
    Matsumoto, Kiyoshi
    Shimoyama, Isao
    SENSORS, 2013, 13 (04): : 4138 - 4145
  • [45] A turn-on and reversible Schiff base fluorescence sensor for Al3+ ion
    Chen, Chang-Hung
    Liao, De-Jhong
    Wan, Chin-Feng
    Wu, An-Tai
    ANALYST, 2013, 138 (09) : 2527 - 2530
  • [46] Highly selective fluorescence turn-on determination of fluoride ions via chromogenic aggregation of a silyloxy-functionalized salicylaldehyde azine
    Zhao, Yun-Hui
    Li, Yubo
    Long, Yunfei
    Zhou, Zhihua
    Tang, Zilong
    Deng, Keqin
    Zhang, Shaowei
    TETRAHEDRON LETTERS, 2017, 58 (13) : 1351 - 1355
  • [47] A tetrazole-based fluorescence "turn-on" sensor for Al(III) and Zn(II) ions and its application in bioimaging
    Ding, Wei-Hua
    Cao, Wei
    Zheng, Xiang-Jun
    Ding, Wan-Jian
    Qiao, Jin-Ping
    Jin, Lin-Pei
    DALTON TRANSACTIONS, 2014, 43 (17) : 6429 - 6435
  • [48] Turn-on signal fluorescence sensor based on DNA derived bio-dots/polydopamine nanoparticles for the detection of glutathione
    Chen, Xiaoxiao
    Li, Pu
    Wu, Gaojun
    Wang, Zhe
    Huang, Chaobiao
    RSC ADVANCES, 2022, 12 (03) : 1807 - 1812
  • [49] A reversible, benzothiazole-based "Turn-on" fluorescence sensor for selective detection of Zn2+ ions in vitro
    Musib, Dulal
    Raza, Md Kausar
    Devi, Salam Sujata
    Roy, Mithun
    JOURNAL OF CHEMICAL SCIENCES, 2020, 132 (01)
  • [50] A turn-on and reversible Schiff-base fluorescence sensor for Al3+ ion
    Lu, Cheng-Yi
    Liu, Yen-Wen
    Hung, Pei-Ju
    Wan, Chin-Feng
    Wu, An-Tai
    INORGANIC CHEMISTRY COMMUNICATIONS, 2013, 35 : 273 - 275