Atomization of lead from whole blood using novel tungsten filaments in electrothermal atomic absorption spectrometry

被引:22
作者
Zhou, Y
Parsons, PJ
Aldous, KM
Brockman, P
Slavin, W
机构
[1] New York State Dept Hlth, Wadsworth Ctr, Albany, NY 12201 USA
[2] SUNY Albany, Dept Chem, Albany, NY 12222 USA
[3] SUNY Albany, Sch Publ Hlth, Dept Environm Hlth & Toxicol, Albany, NY 12201 USA
[4] Exeter Analyt Inc, N Chelmsford, MA 01863 USA
[5] Bonaire Technol, Ridgefield, CT 06877 USA
关键词
D O I
10.1039/b006644n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several novel W-filament designs are investigated and compared as atomization devices for blood Pb measurements by atomic absorption spectrometry. Two designs (short and long wire filaments) an based on rigidly-wound W-filaments from Osram, while a third (etched filament) is based on lithographic imaging and photoetching technology. The filaments are positioned in an aluminum atomization cell that is mounted in the optical path of a compact AAS instrument. This instrument is designed specifically for blood lead testing using W-filament technology with a Pb hollow cathode lamp and incorporates a self-reversal background correction system. Whole blood is diluted 1+4 with a phosphate modifier, Triton X-100 and nitric acid, and 15 muL are deposited on the filament using a micropipette. A simple heating program dries, pyrolyzes and atomizes the sample. Integrated absorbance measurements are used for improved precision and detection limits. Matrix-matched Pb standards are necessary for blood lead calibration. Of the three filaments studied, the long wire filament proved most suitable, with a characteristic mass (m(0)) of 200 pg, a method detection limit (3 sigma) of 1-2 mug dL(-1) (05-0.10 mu mol L-1), and a lifetime of the order of 60-70 firings. Method accuracy is verified using blood lead reference materials from the National Institute of Standards and Technology (SRM 955a,b), the Centers for Disease Control (BLLRS) and the New York State Department of Hearth (RMs 028, 040, and 043). For the long wire filament, blood lead results-below 40 mug dL(-1) were mostly within +/- 1 mug dL(-1) of certified values, and within +/- 10% above 40 mug dL(-1); within-run precision was almost always better than +/- 10%. Additional validation is reported using proficiency test materials and human blood specimens. All blood lead results were within the acceptable limits established by regulatory authorities in the US.
引用
收藏
页码:82 / 89
页数:8
相关论文
共 32 条
[1]  
[Anonymous], 1992, FED REG
[2]   SIMPLE LOW-COST TUNGSTEN-COIL ATOMIZER FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BERNDT, H ;
SCHALDACH, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :709-712
[3]   Determination of lead in whole blood by capacitively coupled microwave plasma atomic emission spectrometry [J].
Besteman, AD ;
Lau, N ;
Liu, DY ;
Smith, BW ;
Winefordner, JD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (07) :479-481
[4]   ANALYTICAL EVALUATION OF A TUNGSTEN COIL ATOMIZER FOR CADMIUM, LEAD, CHROMIUM, MANGANESE, NICKEL AND COBALT DETERMINATION BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BRUHN, CG ;
AMBIADO, FE ;
CID, HJ ;
WOERNER, R ;
TAPIA, J ;
GARCIA, R .
ANALYTICA CHIMICA ACTA, 1995, 306 (2-3) :183-192
[5]   Chemical modifiers in a tungsten coil electrothermal atomizer. Part 1. Determination of lead in hair and blood [J].
Bruhn, CG ;
Neira, JY ;
Valenzuela, GD ;
Nobrega, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (01) :29-35
[6]  
Centers for Disease Control, 1991, PREV LEAD POIS YOUNG
[7]   DETERMINATION OF LEAD IN BLOOD BY SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY AT A CARBON DISK ULTRAMICROELECTRODE [J].
FELDMAN, BJ ;
OSTERLOH, JD ;
HATA, BH ;
DALESSANDRO, A .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :1983-1987
[8]  
FELDMAN BJ, 1995, CLIN CHEM, V41, P557
[9]   DETERMINATION OF CADMIUM IN BIOLOGICAL-MATERIALS BY TUNGSTEN COIL ATOMIC-ABSORPTION SPECTROMETRY [J].
GINE, MF ;
KRUG, FJ ;
SASS, VA ;
REIS, BF ;
NOBREGA, JA ;
BERNDT, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :243-245