Effect of specimen geometry on tensile strength of cortical bone

被引:13
作者
Feng, Liang [1 ]
Jasiuk, Iwona [1 ]
机构
[1] Univ Illinois, Dept Mech Sci & Engn, Urbana, IL 61801 USA
基金
美国国家科学基金会;
关键词
cortical bone; tensile testing; finite element analysis; specimen geometry; tensile strength; MECHANICAL-PROPERTIES; MINERAL-CONTENT; YIELD BEHAVIOR; COMPACT-BONE; ELASTICITY; STRESS; TISSUE; STRAIN;
D O I
10.1002/jbm.a.32837
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We investigate the effect of specimen geometry on the ultimate tensile strength of cortical bone measured by a tensile test. This article is motivated by the fact that there is no clear consensus in the literature on a suitable specimen shape for cortical bone testing. We consider three commonly used tensile test specimen shapes: strip, dumbbell with sharp junctions, and dumbbell with rounded junctions. We conduct this study computationally, using a finite element method, and experimentally by testing porcine femurs. Our results show that local stress concentration factors in the specimen lead to reduced values in the measured tensile strength. The higher the stress concentrations are, the lower is the measured strength. We find that the strip specimens are not a good choice due to high stress concentrations. For the same reason, dumbbell specimens with sharp junctions between the grip and gage sections should also be avoided. The dumbbell shaped tensile test specimens with an arc transition and a maximized radius of fillet are a better choice because such geometry lowers stress concentrations. (C) 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 95A: 580-587, 2010.
引用
收藏
页码:580 / 587
页数:8
相关论文
共 29 条
[1]  
*ASTM, 2006, D63808 ASTM
[2]  
BEDFORD A, 2000, MECH MATER, P520
[3]   The tensile behavior of demineralized bovine cortical bone [J].
Bowman, SM ;
Zeind, J ;
Gibson, LJ ;
Hayes, WC ;
McMahon, TA .
JOURNAL OF BIOMECHANICS, 1996, 29 (11) :1497-1501
[4]   AGING OF BONE TISSUE - MECHANICAL-PROPERTIES [J].
BURSTEIN, AH ;
REILLY, DT ;
MARTENS, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (01) :82-86
[5]   ANISOTROPIC YIELD BEHAVIOR OF BONE UNDER COMBINED AXIAL FORCE AND TORQUE [J].
CEZAYIRLIOGLU, H ;
BAHNIUK, E ;
DAVY, DT ;
HEIPLE, KG .
JOURNAL OF BIOMECHANICS, 1985, 18 (01) :61-69
[6]   INVARIANT PROPERTIES OF THE STRESS IN PLANE ELASTICITY AND EQUIVALENCE CLASSES OF COMPOSITES [J].
CHERKAEV, AV ;
LURIE, KA ;
MILTON, GW .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1992, 438 (1904) :519-529
[7]   OSTEONAL STRUCTURE BETTER PREDICTS TENSILE-STRENGTH OF HEALING BONE THAN VOLUME FRACTION [J].
CLAES, LE ;
WILKE, HJ ;
KIEFER, H .
JOURNAL OF BIOMECHANICS, 1995, 28 (11) :1377-1390
[8]   Tensile yield in compact bone is determined by strain, post-yield behaviour by mineral content [J].
Currey, JD .
JOURNAL OF BIOMECHANICS, 2004, 37 (04) :549-556
[9]   PHYSICAL CHARACTERISTICS AFFECTING THE TENSILE FAILURE PROPERTIES OF COMPACT-BONE [J].
CURREY, JD .
JOURNAL OF BIOMECHANICS, 1990, 23 (08) :837-844
[10]   Prediction of cortical bone elastic constants by a two-level micromechanical model using a generalized self-consistent method [J].
Dong, X. Neil ;
Guo, X. Edward .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (03) :309-316