Improving the Performance of Integrated Power-Hardware-in-the-Loop and Quasi-Static Time-Series Simulations

被引:9
作者
Prabakar, Kumaraguru [1 ]
Palmintier, Bryan [1 ]
Pratt, Annabelle [1 ]
Hariri, Ali [1 ,2 ,3 ]
Mendoza, Ismael [1 ]
Baggu, Murali [1 ]
机构
[1] Natl Renewable Energy Lab, Power Syst Engn Ctr, Golden, CO 80401 USA
[2] Florida State Univ, Tallahassee, FL 32306 USA
[3] Intel Corp, Santa Clara, CA 95054 USA
关键词
Voltage control; Inverters; Hardware; Load modeling; Real-time systems; Mathematical model; Computational modeling; Advanced distribution management system (ADMS); advanced inverter control functions; cosimulation; distribution system; electromagnetic transient (EMT) simulation; hardware-in-the-loop (HIL); power systems simulation; power-hardware-in-the-loop (PHIL); quasi-static time series (QSTS); COMPREHENSIVE APPROACH; IMPLEMENTATION; INTERFACE; STABILITY; DESIGN;
D O I
10.1109/TIE.2020.3029465
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article introduces a novel multirate cosimulation architecture that overcomes previous challenges integrating faster real-time, microseconds-scale, power-hardware-in-the-loop (PHIL) with larger scale but slower, real-time, seconds-scale, quasi-static time-series (QSTS) simulation. Specifically, an intermediate reduced-equivalent electromagnetic transient (EMT) model duplicates the key power system topology to capture high-speed dynamics and converge hardware-power system interactions between QSTS updates. Exchanging multidimensional parameter vectors (loads, control status, etc.) between the QSTS and EMT models enables capturing the interactions of the rich, high-node-count (thousands of electrical nodes) QSTS model with the hardware. This architecture offers full spatial resolution from QSTS, including individual load dynamics, actual distribution management system controls, and nodal voltages. Simultaneously, the intermediate EMT model provides more detailed high-speed transients of key distributed energy resource hardware interactions. In addition, we use careful PHIL interface design and the exchange of complex power data, rather than current, to further improve performance. This cosimulation architecture is demonstrated by testing a simulated distribution system with an interconnected 500-kVA advanced photovoltaic (PV) inverter in PHIL. The architecture successfully captured PV local volt-volt ampere reactive (volt-VAR) control interactions with the larger network under time-varying electrical and weather conditions.
引用
收藏
页码:10938 / 10948
页数:11
相关论文
共 29 条
[1]  
Ainsworth N, 2016, NORTH AMER POW SYMP
[2]  
[Anonymous], 2016, Technical Report, NREL/TP-5D00-65551
[3]  
[Anonymous], 2016, NORTH AMER POW SYMP
[4]   A comprehensive approach to fixed-step simulation of switched circuits [J].
De Kelper, B ;
Dessaint, LA ;
Al-Haddad, K ;
Nakra, H .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2002, 17 (02) :216-224
[5]  
Dufour C., 2006, IECON 2006. 32nd Annual Conference on IEEE Industrial Electronics (IEEE Cat. No. 06CH37763), P5325, DOI 10.1109/IECON.2006.347675
[6]  
Guillaud Xavier, 2015, IEEE Power and Energy Technology Systems Journal, V2, P103
[7]   Real-Time Power-Hardware-in-the-Loop Implementation of Variable-Speed Wind Turbines [J].
Huerta, Francisco ;
Lister Tello, Ronald ;
Prodanovic, Milan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (03) :1893-1904
[8]  
IEEE Guide for Conducting Distribution Impact Studies for Distributed Resource Interconnection, 2014, 154772013 IEEE 154772013 IEEE
[9]  
Jalili-Marandi V., 2013, P INT C POW SYST TRA REAL TIME ELECTROMAG
[10]  
Kuffel R, 1995, ICDS '95 - DIGITAL POWER SYSTEM SIMULATORS, PROCEEDINGS, P199, DOI 10.1109/ICDS.1995.492830