Quantitative colorectal cancer perfusion measurement using dynamic contrast-enhanced multidetector-row computed tomography - Effect of acquisition time and implications for protocols

被引:57
作者
Goh, V
Halligan, S
Hugill, JA
Gartner, L
Bartram, CI
机构
[1] St Marks Hosp, Intestinal Imaging Ctr, Harrow HA1 3UJ, Middx, England
[2] Mt Vernon Hosp, Paul Strickland Scanner Ctr, Northwood HA6 2RN, Middx, England
关键词
computed tomography; perfusion study; rectum; neoplasms; colon;
D O I
10.1097/01.rct.0000152847.00257.d7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To determine the effect of acquisition time on quantitative colorectal cancer perfusion measurement. Methods: Dynamic contrast-enhanced computed tomography (CT) was performed prospectively in 10 patients with histologically proven colorectal cancer using 4-detector row CT (Lightspeed Plus; GE Healthcare Technologies, Waukesha, WI). Tumor blood flow, blood volume, mean transit time, and permeability were assessed for 3 acquisition times (45, 65, and 130 seconds). Mean values for all 4 perfusion parameters for each acquisition time were compared using the paired t test. Results: Significant differences in permeability values were noted between acquisitions of 45 seconds and 65 and 130 seconds, respectively (P = 0.02, P = 0.007). There was no significant difference for values of blood volume, blood flow, and mean transit time between any of the acquisition times. Conclusions: Scan acquisitions of 45 seconds are too short for reliable permeability measurement in the abdomen. Longer acquisition times are required.
引用
收藏
页码:59 / 63
页数:5
相关论文
共 24 条
  • [11] Perfusion CT in patients with advanced bronchial carcinomas:: a novel chance for characterization and treatment monitoring?
    Kiessling, F
    Boese, J
    Corvinus, C
    Ederle, JR
    Zuna, I
    Schoenberg, SO
    Brix, G
    Schmähl, A
    Tuengerthal, S
    Herth, F
    Kauczor, HU
    Essig, M
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (07) : 1226 - 1233
  • [12] Tumor angiogenesis: Molecular pathology, therapeutic targeting, and imaging
    Li, WW
    [J]. ACADEMIC RADIOLOGY, 2000, 7 (10) : 800 - 811
  • [13] Miles K, 1997, FUNCTIONAL COMPUTED
  • [14] FUNCTIONAL IMAGING OF CHANGES IN HUMAN INTRARENAL PERFUSION USING QUANTITATIVE DYNAMIC COMPUTED-TOMOGRAPHY
    MILES, KA
    HAYBALL, MP
    DIXON, AK
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 (10) : 911 - 914
  • [15] CT measurements of capillary permeability within nodal masses: A potential technique for assessing the activity of lymphoma
    Miles, KA
    Kelley, BB
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : 74 - 79
  • [16] MEASUREMENT OF TISSUE PERFUSION BY DYNAMIC COMPUTED-TOMOGRAPHY
    MILES, KA
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (761) : 409 - 412
  • [17] FUNCTIONAL IMAGES OF HEPATIC PERFUSION OBTAINED WITH DYNAMIC CT
    MILES, KA
    HAYBALL, MP
    DIXON, AK
    [J]. RADIOLOGY, 1993, 188 (02) : 405 - 411
  • [18] Perfusion CT for the assessment of tumour vascularity: which protocol?
    Miles, KA
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 : S36 - S42
  • [19] Perfusion CT: a worthwhile enhancement?
    Miles, KA
    Griffiths, MR
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (904) : 220 - 231
  • [20] MEASUREMENT OF HUMAN PANCREATIC PERFUSION USING DYNAMIC COMPUTED-TOMOGRAPHY WITH PERFUSION IMAGING
    MILES, KA
    HAYBALL, MP
    DIXON, AK
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (809) : 471 - 475