Quantitative colorectal cancer perfusion measurement using dynamic contrast-enhanced multidetector-row computed tomography - Effect of acquisition time and implications for protocols

被引:57
作者
Goh, V
Halligan, S
Hugill, JA
Gartner, L
Bartram, CI
机构
[1] St Marks Hosp, Intestinal Imaging Ctr, Harrow HA1 3UJ, Middx, England
[2] Mt Vernon Hosp, Paul Strickland Scanner Ctr, Northwood HA6 2RN, Middx, England
关键词
computed tomography; perfusion study; rectum; neoplasms; colon;
D O I
10.1097/01.rct.0000152847.00257.d7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To determine the effect of acquisition time on quantitative colorectal cancer perfusion measurement. Methods: Dynamic contrast-enhanced computed tomography (CT) was performed prospectively in 10 patients with histologically proven colorectal cancer using 4-detector row CT (Lightspeed Plus; GE Healthcare Technologies, Waukesha, WI). Tumor blood flow, blood volume, mean transit time, and permeability were assessed for 3 acquisition times (45, 65, and 130 seconds). Mean values for all 4 perfusion parameters for each acquisition time were compared using the paired t test. Results: Significant differences in permeability values were noted between acquisitions of 45 seconds and 65 and 130 seconds, respectively (P = 0.02, P = 0.007). There was no significant difference for values of blood volume, blood flow, and mean transit time between any of the acquisition times. Conclusions: Scan acquisitions of 45 seconds are too short for reliable permeability measurement in the abdomen. Longer acquisition times are required.
引用
收藏
页码:59 / 63
页数:5
相关论文
共 24 条
  • [1] TISSUE MEAN TRANSIT-TIME FROM DYNAMIC COMPUTED-TOMOGRAPHY BY A SIMPLE DECONVOLUTION TECHNIQUE
    AXEL, L
    [J]. INVESTIGATIVE RADIOLOGY, 1983, 18 (01) : 94 - 99
  • [3] Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method
    Bae, KT
    Tran, HQ
    Heiken, JP
    [J]. RADIOLOGY, 2004, 231 (03) : 732 - 736
  • [4] Brown, 1998, BLOOD PERFUSION MICR
  • [5] Cenic A, 2000, AM J NEURORADIOL, V21, P462
  • [6] CT measurement of perfusion and permeability within lymphoma masses and its ability to assess grade, activity, and chemotherapeutic response
    Dugdale, PE
    Miles, KA
    Bunce, I
    Kelley, BB
    Leggett, DAC
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (04) : 540 - 547
  • [7] Perfusion CT with iodinated contrast material
    Eastwood, JD
    Lev, MH
    Provenzale, JM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (01) : 3 - 12
  • [8] Functional CT imaging of the acute hyperemic response to radiation therapy of the prostate gland: Early experience
    Harvey, CJ
    Blomley, MJK
    Dawson, P
    Morgan, JA
    Dooher, A
    Deponte, J
    Vernon, CC
    Price, P
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (01) : 43 - 49
  • [9] Cerebral perfusion CT: Technique and clinical applications
    Hoeffner, EG
    Case, I
    Jain, R
    Gujar, SK
    Shah, GV
    Deveikis, JP
    Carlos, RC
    Thompson, BG
    Harrigan, MR
    Mukherji, SK
    [J]. RADIOLOGY, 2004, 231 (03) : 632 - 644
  • [10] Phase II, randomized trial comparing bevacizumab plus fluorouracil (FU) leucovorin (LV) with FU/LV alone in patients with metastatic colorectal cancer
    Kabbinavar, F
    Hurwitz, HI
    Fehrenbacher, L
    Meropol, NJ
    Novotny, WF
    Lieberman, G
    Griffing, S
    Bergsland, E
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (01) : 60 - 65