Predictors of long-term compliance with continuous positive airway pressure

被引:184
作者
Kohler, Malcolm [1 ,2 ,3 ]
Smith, Debbie [3 ]
Tippett, Victoria [3 ]
Stradling, John R. [3 ]
机构
[1] Univ Zurich Hosp, Sleep Disorders Ctr, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Div Pulm, CH-8091 Zurich, Switzerland
[3] Churchill Hosp, Sleep Unit, Oxford Ctr Resp Med, Oxford OX3 7LJ, England
关键词
OBSTRUCTIVE SLEEP-APNEA; APNOEA/HYPOPNOEA SYNDROME; DAYTIME SLEEPINESS; THERAPY; TRIAL; CPAP; MEN;
D O I
10.1136/thx.2010.135848
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background There are very few data on objectively assessed long-term compliance with continuous positive airway pressure (CPAP). No single factor has been consistently identified as predictive of continued CPAP use. Methods Adherence to and associations with objective CPAP use were examined in 639 of 3900 patients in whom CPAP treatment was started between 1994 and 2005. Kaplan-Meier survival analyses were used to estimate the proportion of patients still on CPAP. Cox regression models were used to explore the effects of covariates on continued use of CPAP. Results The median (IQR) follow-up time after initiating CPAP therapy was 3.9 (1.5-6.9) years and the average use of CPAP was 6.2 (4.5-7.3) h/night. The percentage of patients adherent to CPAP after 5 and 10 years was 81% and 70%, respectively. Multivariate analysis, including gender, age, neck circumference, Epworth Sleepiness Score, oxygen desaturation index (ODI) and research study participation, indicated that ODI was the only clinical variable independently associated with long-term adherence to CPAP (HR per 1 event=0.97, p<0.001, 95% CI 0.96 to 0.98). ODI categories were significantly associated with the risk for stopping CPAP in multivariate analysis (using ODI group 0-15/h as reference, HR for ODI group >15-30/h=0.68, p=0.100, 95% CI 0.43 to 1.08; for ODI group >30-60/h=0.37, p<0.001, 95% CI 0.22 to 0.60; and for ODI group >60/h=0.17, p=0.001, 95% CI 0.06 to 0.48). Conclusions The majority of patients with sleep-disordered breathing are using CPAP in the long term and the severity of sleep-disordered breathing rather than sleepiness determines long-term adherence to CPAP therapy.
引用
收藏
页码:829 / 832
页数:4
相关论文
共 16 条
[1]   A behavioural test to assess daytime sleepiness in obstructive sleep apnoea [J].
Bennett, LS ;
Stradling, JR ;
Davies, RJO .
JOURNAL OF SLEEP RESEARCH, 1997, 6 (02) :142-145
[2]   EFFECT OF CONTINUOUS POSITIVE AIRWAY PRESSURE TREATMENT ON DAYTIME FUNCTION IN SLEEP APNOEA/HYPOPNOEA SYNDROME [J].
ENGLEMAN, HM ;
MARTIN, SE ;
DEARY, IJ ;
DOUGLAS, NJ .
LANCET, 1994, 343 (8897) :572-575
[3]   Reduction in motor vehicle collisions following treatment of sleep apnoea with nasal CPAP [J].
George, CFP .
THORAX, 2001, 56 (07) :508-512
[4]   Cost-effectiveness of using continuous positive airway pressure in the treatment of severe obstructive sleep apnoea/hypopnoea syndrome in the UK [J].
Guest, J. F. ;
Helter, M. T. ;
Morga, A. ;
Stradling, J. R. .
THORAX, 2008, 63 (10) :860-865
[5]   Inflammation, oxidative stress, and repair capacity of the vascular endothelium in obstructive sleep apnea [J].
Jelic, Sanja ;
Padeletti, Margherita ;
Kawut, Steven M. ;
Higgins, Christopher ;
Canfield, Stephen M. ;
Onat, Duygu ;
Colombo, Paolo C. ;
Basner, Robert C. ;
Factor, Phillip ;
LeJemtel, Thierry H. .
CIRCULATION, 2008, 117 (17) :2270-2278
[6]   A NEW METHOD FOR MEASURING DAYTIME SLEEPINESS - THE EPWORTH SLEEPINESS SCALE [J].
JOHNS, MW .
SLEEP, 1991, 14 (06) :540-545
[7]  
Krieger J, 1996, SLEEP, V19, P136
[8]   Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational study [J].
Marin, JM ;
Carrizo, SJ ;
Vicente, E ;
Agusti, AGN .
LANCET, 2005, 365 (9464) :1046-1053
[9]   Long-term use of CPAP therapy for sleep apnea/hypopnea syndrome [J].
McArdle, N ;
Devereux, G ;
Heidarnejad, H ;
Engleman, HM ;
Mackay, TW ;
Douglas, NJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (04) :1108-1114
[10]   PREDICTIVE FACTORS OF LONG-TERM COMPLIANCE WITH NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE TREATMENT IN SLEEP-APNEA SYNDROME [J].
MEURICE, JC ;
DORE, P ;
PAQUEREAU, J ;
NEAU, JP ;
INGRAND, P ;
CHAVAGNAT, JJ ;
PATTE, F .
CHEST, 1994, 105 (02) :429-433