Image noise and dose performance across a clinical population: Patient size adaptation as a metric of CT performance

被引:18
作者
Ria, Francesco [1 ,2 ,3 ,4 ]
Wilson, Joshua Mark [2 ]
Zhang, Yakun [1 ,2 ]
Samei, Ehsan [1 ,2 ]
机构
[1] Duke Univ Hlth Syst, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Duke Univ Hlth Syst, Clin Imaging Phys Grp, Durham, NC 27705 USA
[3] Ctr Diagnost Italiano, Dipartimento Diagnost Immagini, I-20147 Milan, Italy
[4] Fdn Bracco, Alumnus ProgettoDiventero, I-20122 Milan, Italy
关键词
CT performance; image noise; patient population; radiation dose; TUBE CURRENT MODULATION; REDUCTION;
D O I
10.1002/mp.12172
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Modern CT systems adjust X-ray flux accommodating for patient size to achieve certain image noise values. The effectiveness of this adaptation is an important aspect of CT performance and should ideally be characterized in the context of real patient cases. The objective of this study was to characterize CT performance with a new metric that includes image noise and radiation dose across a clinical patient population. Materials and methods: The study included 1526 examinations performed by three CT scanners (one GE Healthcare Discovery CT750HD, one GE Healthcare Lightspeed VCT, and one Siemens SOMATOM definition Flash) used for two routine clinical protocols (abdominopelvic with contrast and chest without contrast). An institutional monitoring system recorded all the data involved in the study. The dose-patient size and noise-patient size dependencies were linearized by considering a first-order approximation of analytical models that describe the relationship between ionization dose and patient size, as well as image noise and patient size. A 3D-fit was performed for each protocol and each scanner with a planar function, and the root mean square error (RMSE) values were estimated as a metric of CT adaptability across the patient population. Results: The data show different scanner dependencies in terms of adaptability: the RMSE values for the three scanners are between 0.0385 HU1/2 and 0.0215 HU1/2. Conclusion: A theoretical relationship between image noise, CTDIvol, and patient size was determined based on real patient data. This relationship may be interpreted as a new metric related to the scanners' adaptability concerning image quality and radiation dose across a patient population. This method could be implemented to investigate the adaptability related to other image quality indexes and radiation dose in a clinical population. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:2141 / 2147
页数:7
相关论文
共 16 条
  • [1] [Anonymous], 2014, 220 AAPM
  • [2] [Anonymous], 2007, The Recommendations of the International Commission on Radiological Protection, V103
  • [3] [Anonymous], 2005, 05016 MHRA, DOI DOI 10.13140/RG.2.1.3128.4720
  • [4] Boone S, 2011, 204 AAPM
  • [5] Automated Technique to Measure Noise in Clinical CT Examinations
    Christianson, Olav
    Winslow, James
    Frush, Donald P.
    Samei, Ehsan
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (01) : W93 - W99
  • [6] Automated size-specific CT dose monitoring program: Assessing variability in CT dose
    Christianson, Olav
    Li, Xiang
    Frush, Donald
    Samei, Ehsan
    [J]. MEDICAL PHYSICS, 2012, 39 (11) : 7131 - 7139
  • [7] Dose reduction in CT by anatomically adapted tube current modulation. 1. Simulation studies
    Gies, M
    Kalender, WA
    Wolf, H
    Suess, C
    Madsen, MT
    [J]. MEDICAL PHYSICS, 1999, 26 (11) : 2235 - 2247
  • [8] ICRP, 2007, ANN ICRP, V103, P1
  • [9] Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
    Kalender, WA
    Wolf, H
    Suess, C
    [J]. MEDICAL PHYSICS, 1999, 26 (11) : 2248 - 2253
  • [10] Techniques and applications of automatic tube current modulation for CT
    Kalra, MK
    Maher, MM
    Toth, TL
    Schmidt, B
    Westerman, BL
    Morgan, HT
    Saini, S
    [J]. RADIOLOGY, 2004, 233 (03) : 649 - 657