TOWARD A REAL-TIME IN VIVO DOSIMETRY SYSTEM USING PLASTIC SCINTILLATION DETECTORS

被引:80
作者
Archambault, Louis [1 ]
Briere, Tina M. [1 ]
Poenisch, Falk [1 ]
Beaulieu, Luc [3 ]
Kuban, Deborah A. [2 ]
Lee, Andrew [2 ]
Beddar, Sam [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[3] Ctr Hosp Univ Quebec, Dept Radiooncol, Quebec City, PQ, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2010年 / 78卷 / 01期
关键词
Plastic scintillation detectors; in vivo dosimetry; real-time monitoring; rectal balloons; ENERGY BEAM DOSIMETRY; RADIATION-THERAPY; OPTICAL MEASUREMENTS; RADIOCHROMIC MEDIUM; FIBER DOSIMETER; RADIOTHERAPY; BRACHYTHERAPY; ACCELERATOR; PERFORMANCE; CANCER;
D O I
10.1016/j.ijrobp.2009.11.025
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: In the present study, we have presented and validated a plastic scintillation detector (PSD) system designed for real-time multiprobe in vivo measurements. Methods and Materials: The PSDs were built with a dose-sensitive volume of 0.4 mm(3). The PSDs were assembled into modular detector patches, each containing five closely packed PSDs. Continuous dose readings were performed every 150 ms, with a gap between consecutive readings of < 0.3 ms. We first studied the effect of electron multiplication. We then assessed system performance in acrylic and anthropomorphic pelvic phantoms. Results: The PSDs were compatible with clinical rectal balloons and were easily inserted into the anthropomorphic phantom. With an electron multiplication average gain factor of 40, a twofold increase in the signal/noise ratio was observed, making near real-time dosimetry feasible. Under calibration conditions, the PSDs agreed with the ion chamber measurements to 0.08%. Precision, evaluated as a function of the total dose delivered, ranged from 2.3% at 2 cGy to 0.4% at 200 cGy. Conclusion: Real-time PSD measurements are highly accurate and precise. These PSDs can be mounted onto rectal balloons, transforming these clinical devices into in vivo dose detectors without modifying current clinical practice. Real-time monitoring of the dose delivered near the rectum during prostate radiotherapy should help radiation oncologists protect this sensitive normal structure. (C) 2010 Elsevier Inc.
引用
收藏
页码:280 / 287
页数:8
相关论文
共 27 条
[1]   An algorithm for real-time dosimetry in intensity-modulated radiation therapy using the radioluminescence signal from Al2O3:C [J].
Andersen, C. E. ;
Marckmann, C. J. ;
Aznar, M. C. ;
Botter-Jensen, L. ;
Kjaer-Kristoffersen, F. ;
Medin, J. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :7-13
[2]  
ANDERSON CE, MED PHYS, V36, P5033
[3]  
[Anonymous], AM J CLIN ONCOL
[4]   Measurement accuracy and Cerenkov removal for high performance, high spatial resolution scintillation dosimetry [J].
Archambault, L ;
Beddar, AS ;
Gingras, L ;
Roy, R ;
Beaulieu, L .
MEDICAL PHYSICS, 2006, 33 (01) :128-135
[5]   Plastic scintillation dosimetry: Optimal selection of scintillating fibers and scintillators [J].
Archambault, L ;
Arsenault, J ;
Gingras, L ;
Beddar, AS ;
Roy, R ;
Beaulieu, L .
MEDICAL PHYSICS, 2005, 32 (07) :2271-2278
[6]   Transient noise characterization and filtration in CCD cameras exposed to stray radiation from a medical linear accelerator [J].
Archambault, Louis ;
Briere, Tina Marie ;
Beddar, Sam .
MEDICAL PHYSICS, 2008, 35 (10) :4342-4351
[7]   Water-equivalent dosimeter array for small-field external beam radiotherapy [J].
Archambault, Louis ;
Beddar, A. Sam ;
Gingras, Luc ;
Lacroix, Frederic ;
Roy, Rene ;
Beaulieu, Luc .
MEDICAL PHYSICS, 2007, 34 (05) :1583-1592
[8]   Water equivalent plastic scintillation detectors in radiation therapy [J].
Beddar, A. S. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :1-6
[9]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[10]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900