Determination of sulfa antibiotic residues in river and particulate matter by field-amplified sample injection-capillary zone electrophoresis

被引:18
|
作者
Li, Xinghua [1 ,2 ]
Yang, Yuqin [1 ,2 ]
Miao, Junjie [1 ,2 ]
Yin, Zhendong [1 ,2 ]
Zhai, Yijing [3 ]
Shi, Hongmei [1 ,2 ]
Li, Zengning [3 ]
机构
[1] Hebei Med Univ, Sch Publ Hlth, Shijiazhuang, Hebei, Peoples R China
[2] Hebei Med Univ, Key Lab Environm & Human Hlth Hebei Prov, Shijiazhuang, Hebei, Peoples R China
[3] Hebei Med Univ, Dept Nutr, Hosp 1, Shijiazhuang, Hebei, Peoples R China
基金
中国国家自然科学基金;
关键词
Capillary zone electrophoresis; Diode array detector; Environmental sample; Field-amplified sample injection; Sulfa antibiotic residues; LIQUID-LIQUID MICROEXTRACTION; HIGH-SENSITIVITY ANALYSIS; DYNAMIC PH JUNCTION; SOLVENT STACKING; WASTE-WATER; ONLINE CONCENTRATION; MICELLE; PRECONCENTRATION; CHROMATOGRAPHY; SULFONAMIDES;
D O I
10.1002/elps.202000122
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present research, field-amplified sample injection-CZE (FASI-CZE) coupled with a diode array detector was established to determine trace level sulfa antibiotic. Sulfathiazole, sulfadiazine, sulfamethazine, sulfadimethoxine, sulfamethoxazole, and sulfisoxazole were selected as analytes for the experiments. The background electrolyte solution consisted of 70.0 mmol/L borax and 60.0 mmol/L boric acid (including 10% methanol, pH 9.1). The plug was 2.5 mmol/L borax, which was injected into the capillary at a pressure of 0.5 psi for 5 s. Then the sample was injected into the capillary at an injection voltage of -10 kV for 20 s. The electrophoretic separation was carried out under a voltage of +19 kV. The capillary temperature was maintained at 20 degrees C throughout the analysis, and six sulfonamides were completely separated within 35 min. Compared with pressure injection-CZE, the sensitivity of FASI-CZE was increased by 6.25-10.0 times, and the LODs were reduced from 0.2-0.5 to 0.02-0.05 mu g/mL. The method was applied to the determination of sulfonamides in river water and particulate matter samples. The recoveries were 78.59-106.59%. The intraday and interday precisions were 2.89-7.35% and 2.77-7.09%, respectively. This provides a simpler and faster method for the analysis of sulfa antibiotic residues in environmental samples.
引用
收藏
页码:1584 / 1591
页数:8
相关论文
共 50 条
  • [41] Trace analysis of acetylcholinesterase inhibitors with antipsychotic drugs for Alzheimer's disease by capillary electrophoresis with on column field-amplified sample injection
    Wang, Yi-Rou
    Yang, Yuan-Han
    Lu, Chi-Yu
    Lin, Shun-Jin
    Chen, Su-Hwei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (10) : 3233 - 3242
  • [42] Detection of 2,2′-Azobis(2-amidinopropane) Dihydrochloride in Polyvinylpyrrolidone by Capillary Electrophoresis with Field-Amplified Sample Injection
    Chunli Lou
    Mengmeng Zheng
    Yao Xu
    Yuting Shen
    Jingwu Kang
    Chromatographia, 2019, 82 : 1579 - 1583
  • [43] Chemiluminescence detection of 10-16 mol/L level Co(II) with field-amplified sample injection in capillary electrophoresis
    Liu, YM
    Liu, EB
    Cheng, JK
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2001, 22 (12): : 2005 - 2007
  • [44] Hyphenation of field-amplified sample injection and transient isotachophoresis in CE for the determination of sotalol and metoprolol in human urine samples
    Xu, Lei
    Meng, Weiqi
    Lu, Jing
    Cui, Fengjuan
    Gao, Lidi
    Chen, Lin
    Xin, Yang
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (11) : 2193 - 2200
  • [45] Simultaneous Determination of Pyridine-Triphenylborane Anti-Fouling Agent and Its Degradation Products in Paint-Waste Samples Using Capillary Zone Electrophoresis with Field-Amplified Sample Injection
    Kaewchuay, Netnapit
    Fukushi, Keiichi
    Tsuboi, Ai
    Okamura, Hideo
    Saito, Keiitsu
    Hirokawa, Takeshi
    ANALYTICAL SCIENCES, 2012, 28 (12) : 1191 - 1196
  • [46] Capillary electrophoresis with field-amplified sample stacking for simultaneous determination of indacaterol and glycopyrronium in inhaler capsules: Application to human plasma and urine
    Zayed, Sahar
    Belal, Fathalla
    MICROCHEMICAL JOURNAL, 2020, 155
  • [47] Determination of D-amphetamine and diphenhydramine in beagle dog plasma by a 96-well formatted liquid-liquid extraction and capillary zone electrophoresis with field-amplified sample stacking
    Li, Ji
    Zhang, Lingli
    Cheng, Xianliang
    Zhang, Lei
    Shen, Baochun
    Qing, Chen
    Fan, Guorong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 156 : 263 - 271
  • [48] SPECIATION OF SELENIUM AND ARSENIC COMPOUNDS IN NATURAL-WATERS BY CAPILLARY ZONE ELECTROPHORESIS AFTER ON-COLUMN PRECONCENTRATION WITH FIELD-AMPLIFIED INJECTION
    LI, K
    LI, SFY
    ANALYST, 1995, 120 (02) : 361 - 366
  • [49] Separation and determination of acesulfame-K in soy sauce by capillary electrophoresis with contactless conductivity detection using liquid-liquid extraction and field-amplified sample injection
    Chen Hushui
    Jiang Jiankun
    Yi Jia
    Xie Tianyao
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (06) : 708 - 714
  • [50] Analysis of urinary neurotransmitters by capillary electrophoresis: Sensitivity enhancement using field-amplified sample injection and molecular imprinted polymer solid phase extraction
    Claude, Berengere
    Nehme, Reine
    Morin, Philippe
    ANALYTICA CHIMICA ACTA, 2011, 699 (02) : 242 - 248