On the possibility of silicon nitride as a ceramic for structural orthopaedic implants. Part II: chemical stability and wear resistance in body environment

被引:72
作者
Mazzocchi, Mauro [1 ]
Gardini, Davide [1 ]
Traverso, Pier Luigi [2 ]
Faga, Maria Giulia [3 ]
Bellosi, Alida [1 ]
机构
[1] CNR, Inst Sci & Technol Ceram, I-48018 Faenza, Ravenna, Italy
[2] CNR, Harine Sci Inst Unit Genova, I-16149 Genoa, Italy
[3] CNR, Inst Sci & Technol Ceram Unit, I-10135 Turin, Italy
关键词
D O I
10.1007/s10856-008-3437-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In Part I, the processing, microstructure and mechanical properties of three silicon nitride-based ceramics were examined and their non-toxicity was demonstrated. In this Part II, some features critical to biomedical applications were investigated: (i) the wetting behaviour against aqueous media, including physiological solutions; (ii) the chemical stability in water and in physiological solutions; and (iii) the wear resistance, measured under experimental procedures that simulate the conditions typical of the hip joint prosthesis. The results confirmed that silicon nitride may serve as a biomaterial for bone substitution in load bearing prosthesis.
引用
收藏
页码:2889 / 2901
页数:13
相关论文
共 45 条
[1]  
ABREAU CS, 2002, KEY ENG MATER, V230, P919
[2]   WETTABILITY AND INTERFACIAL INTERACTIONS IN BIOCERAMIC-BODY-LIQUID SYSTEMS [J].
AGATHOPOULOS, S ;
NIKOLOPOULOS, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (04) :421-429
[3]  
AGATHOPOULOS S, 1995, EUROCERAMICS 4, V8, P319
[4]   WEAR PROPERTIES OF SI3N4 IN ROLLING-SLIDING CONTACT [J].
AKAZAWA, M ;
KATO, K .
WEAR, 1988, 124 (02) :123-132
[5]   Improvement in zirconia osseointegration by means of a biological glass coating:: An in vitro and in vivo investigation [J].
Aldini, NN ;
Fini, M ;
Giavaresi, G ;
Torricelli, P ;
Martin, L ;
Giardino, R ;
Ravaglioli, A ;
Krajewski, A ;
Mazzocchi, M ;
Dubini, B ;
Ponzi-Bossi, MG ;
Rustichelli, F ;
Stanic, V .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 61 (02) :282-289
[6]   Wettability and surface charge of Si3N4-bioglass composites in contact with simulated physiological liquids [J].
Amaral, M ;
Lopes, MA ;
Santos, JD ;
Silva, RF .
BIOMATERIALS, 2002, 23 (20) :4123-4129
[7]   Densification route and mechanical properties of Si3N4-bioglass biocomposites [J].
Amaral, M ;
Lopes, MA ;
Silva, RF ;
Santos, JD .
BIOMATERIALS, 2002, 23 (03) :857-862
[8]   Colloidal protein solutions as a new standard sensor for adhesive wettability measurements [J].
Annarelli, CC ;
Fornazero, J ;
Cohen, R ;
Bert, J ;
Besse, JL .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1999, 213 (02) :386-394
[9]  
BELLOSI A, 1992, J EUROP CERAM SOC, P983
[10]  
BELLOSI A, 1999, NATO ARW SERIES, P285