Iridium Oxide Enabled Sensors Applications

被引:12
作者
Dong, Qiuchen [1 ]
Sun, Xiangcheng [2 ]
He, Songbing [3 ]
机构
[1] Xian Jiaotong Liverpool Univ, Dept Chem, 111 Ren Rd,Suzhou Ind Pk, Suzhou 215123, Peoples R China
[2] Rochester Inst Technol, Dept Chem Engn, Rochester, NY 14623 USA
[3] Soochow Univ, Dept Gen Surg, Affiliated Hosp 1, Suzhou 215006, Peoples R China
基金
美国国家科学基金会;
关键词
iridium oxide; sensors; biosensors; future trends; METAL-ORGANIC FRAMEWORK; PH-SENSOR; LABEL-FREE; REFERENCE ELECTRODE; CHAIN-REACTION; ELECTROCHEMICAL DETECTION; ISOTHERMAL AMPLIFICATION; GLUCOSE; FILM; DNA;
D O I
10.3390/catal11101164
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
There have been numerous studies applying iridium oxides in different applications to explore their proton-change-based reactions since the 1980s. Iridium oxide can be fabricated directly by applying electrodeposition, sputter-coating method, or oxidation of iridium wire. Generally, there have been currently two approaches in applying iridium oxide to enable its sensing applications. One was to improve or create different electrolytes with (non-)electrodeposition method for better performance of Nernst Constant with the temperature-related system. The mechanism behind the scenes were summarized herein. The other was to change the structure of iridium oxide through different kinds of templates such as photolithography patterns, or template-assisted direct growth methods, etc. to improve the sensing performance. The detection targets varied widely from intracellular cell pH, glucose in an artificial sample or actual urine sample, and the hydrogen peroxide, glutamate or organophosphate pesticides, metal-ions, etc. This review paper has focused on the mechanism of electrodeposition of iridium oxide in aqueous conditions and the sensing applications towards different biomolecules compounds. Finally, we summarize future trends on Iridium oxide based sensing and predict future work that could be further explored.</p>
引用
收藏
页数:34
相关论文
共 108 条
[1]  
Abu Rhayem E, 2002, J ELECTROANAL CHEM, V538, P153, DOI 10.1016/S0022-0728(02)01142-7
[2]   PROPERTIES OF THERMALLY PREPARED IRIDIUM DIOXIDE ELECTRODES [J].
ARDIZZONE, S ;
CARUGATI, A ;
TRASATTI, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1981, 126 (1-3) :287-292
[3]   Iridium oxide films as propane sensors [J].
Avila-Garcia, Alejandro ;
Chaudhary, Archana ;
Rojas-Chavez, H. .
THIN SOLID FILMS, 2021, 724
[4]   Bioactive Paper Sensor Based on the Acetylcholinesterase for the Rapid Detection of Organophosphate and Carbamate Pesticides [J].
Badawy, Mohamed E. I. ;
El-Aswad, Ahmed F. .
INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 2014
[5]  
Bard A.J., 2001, ELECTROCHEMICAL METH, V2, P482
[6]   Evaluation of flow injection analysis for determination of urea in sheep's and cow's milk [J].
Baumgartner, M ;
Flöck, M ;
Winter, P ;
Luf, P ;
Baumgartner, W .
ACTA VETERINARIA HUNGARICA, 2002, 50 (03) :263-271
[7]   Fabrication of anodically electrodeposited iridium oxide film pH microelectrodes for microenvironmental studies [J].
Bezbaruah, AN ;
Zhang, TC .
ANALYTICAL CHEMISTRY, 2002, 74 (22) :5726-5733
[8]   Fiber-Based Electrochemical Biosensors for Monitoring pH and Transient Neurometabolic Lactate [J].
Booth, Marsilea A. ;
Gowers, Sally A. N. ;
Hersey, Melinda ;
Samper, Isabelle C. ;
Park, Seongjun ;
Anikeeva, Polina ;
Hashemi, Parastoo ;
Stevens, Molly M. ;
Boutelle, Martyn G. .
ANALYTICAL CHEMISTRY, 2021, 93 (17) :6646-6655
[9]   Towards a reliable and high sensitivity O2-independent glucose sensor based on Ir oxide nanoparticles [J].
Campbell, H. B. ;
Elzanowska, H. ;
Birss, V. I. .
BIOSENSORS & BIOELECTRONICS, 2013, 42 :563-569
[10]   Cu3(hexaiminotriphenylene)2: An Electrically Conductive 2D Metal-Organic Framework for Chemiresistive Sensing [J].
Campbell, Michael G. ;
Sheberla, Dennis ;
Liu, Sophie F. ;
Swager, Timothy M. ;
Dinca, Mircea .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2015, 54 (14) :4349-4352