Partial discharge location based on time difference of energy accumulation curve of multiple signals

被引:31
作者
Tang, J. [1 ]
Xie, Y. [1 ]
机构
[1] Chongqing Univ, State Key Lab, Chongqing 400030, Peoples R China
关键词
D O I
10.1049/iet-epa.2010.0029
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Acquired partial discharge (PD) signals are always affected by various noises in the process of propagation and detection. These errors have great impact on the accuracy of location of the PD source. In this study, a new PD location algorithm based on the time difference on an energy accumulation curve of multiple signals is proposed to solve this problem. First, errors from different propagation paths of signals are eliminated by correlation shift. Then, averaged signal is used to calculate accumulated energy curves. By searching the maximum correlation of those curves, the time differences of signals are calculated to locate the PD sources. This method has been used in a transformer model in the laboratory and it is proved to be a more effective way to locate the PD source in the transformer model compared to the single signal method. Based on this algorithm, the errors of time difference are in 0.1 ns range and errors of the PD source positions are in centimetre range.
引用
收藏
页码:175 / 180
页数:6
相关论文
共 16 条
[1]  
Danikas MG, 1996, EUR T ELECTR POWER, V6, P217
[2]  
Danikas MG, 1998, EUR T ELECTR POWER, V8, P405
[3]  
Danikas MG, 1996, EUR T ELECTR POWER, V6, P445, DOI 10.1002/etep.4450060616
[4]  
Heinrich R, 2000, EUR T ELECTR POWER, V10, P161, DOI 10.1002/etep.4450100306
[5]   Recent trend of the partial discharge measurement technique using the UHF electromagnetic wave detection method [J].
Hikita, Masayuki ;
Ohtsuka, Shinya ;
Matsumoto, Satoshi .
IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2007, 2 (05) :504-509
[6]   Partial discharge monitoring for power transformers using UHF sensors - part 2: Field experience [J].
Judd, MD ;
Yang, L ;
Hunter, IBB .
IEEE ELECTRICAL INSULATION MAGAZINE, 2005, 21 (03) :5-13
[7]   Analysis and localization of abnormal partial discharge activity in generator units [J].
Pemen, A. J. M. ;
van der Laan, P. C. T. .
EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2007, 17 (02) :191-206
[8]  
PETERM E, 1995, IEEE T ELECT INSUL M, V41, P613
[9]   Experimental Comparison of UHF Sensor Types for PD Location Applications [J].
Pinpart, T. ;
Judd, M. D. .
2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, :26-30
[10]  
SANDER M, 2005, P 2005 INT S EL INS, P698