First experience of 192Ir source stuck event during high-dose-rate brachytherapy in Japan

被引:3
作者
Kumagai, Shinobu [1 ]
Arai, Norikazu [1 ]
Takata, Takeshi [2 ]
Kon, Daisuke [1 ]
Saitoh, Toshiya [3 ]
Oba, Hiroshi [4 ]
Furui, Shigeru [4 ]
Kotoku, Jun'ichi [2 ]
Shiraishi, Kenshiro [4 ]
机构
[1] Teikyo Univ Hosp, Cent Radiol Div, Tokyo, Japan
[2] Teikyo Univ, Grad Sch Med Care & Technol, Tokyo, Japan
[3] Chiyoda Technol Corp Co Ltd, Tokyo, Japan
[4] Teikyo Univ, Dept Radiol, Sch Med, Tokyo, Japan
基金
日本学术振兴会;
关键词
brachytherapy; medical event; Monte Carlo simulation; FAILURE MODES; SAFETY; ERRORS; VERIFICATION; AAPM;
D O I
10.5114/jcb.2020.92401
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To share the experience of an iridium-192 (Ir-192) source stuck event during high-dose-rate (HDR) brachytherapy for cervical cancer. Material and methods: In 2014, we experienced the first source stuck event in Japan when treating cervical cancer with HDR brachytherapy. The cause of the event was a loose screw in the treatment device that interfered with the gear reeling the source. This event had minimal clinical effects on the patient and staff; however, after the event, we created a normal treatment process and an emergency process. In the emergency processes, each staff member is given an appropriate role. The dose rate distribution calculated by the new Monte Carlo simulation system was used as a reference to create the process. Results: According to the calculated dose rate distribution, the dose rates inside the maze, near the treatment room door, and near the console room were congruent to 10(-2) [cGy . h(-1)], 10(-3) [cGy . h(-1)], and << 10(-3) [cGy . h(-1)], respectively. Based on these findings, in the emergency process, the recorder was evacuated to the console room, and the rescuer waited inside the maze until the radiation source was recovered. This emergency response manual is currently a critical work-flow once a year with vendors. Conclusions: We reported our experience of the source stuck event. Details of the event and proposed emergency process will be helpful in managing a patient safety program for other HDR brachytherapy users.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 20 条
  • [1] Advisory Committee on Medical Uses of Isotopes, 2011, REP MED EV SUBC
  • [2] Independent brachytherapy plan verification software: Improving efficacy and efficiency
    Damato, Antonio L.
    Devlin, Phillip M.
    Bhagwat, Mandar S.
    Buzurovic, Ivan
    Friesen, Scott
    Hansen, Jorgen L.
    Lee, Larissa J.
    Molodowitch, Christina
    Nguyen, Paul L.
    O'Farrell, Desmond A.
    Viswanathan, Akila N.
    Williams, Christopher L.
    Killoran, Joseph H.
    Cormack, Robert A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 113 (03) : 420 - 424
  • [3] Brachytherapy patient safety events in an academic radiation medicine program
    Felder, Shira
    Morley, Lyndon
    Ng, Elizabeth
    Chan, Kitty
    Ballantyne, Heather
    Di Tomasso, Anne
    Borg, Jette
    Bissonnette, Jean-Pierre
    Breen, Stephen
    Waldron, John
    Rink, Alexandra
    Milosevic, Michael
    [J]. BRACHYTHERAPY, 2018, 17 (01) : 16 - 23
  • [4] A streamlined failure mode and effects analysis
    Ford, Eric C.
    Smith, Koren
    Terezakis, Stephanie
    Croog, Victoria
    Gollamudi, Smitha
    Gage, Irene
    Keck, Jordie
    DeWeese, Theodore
    Sibley, Greg
    [J]. MEDICAL PHYSICS, 2014, 41 (06)
  • [5] The report of Task Group 100 of the AAPM: Application of risk analysis methods to radiation therapy quality management
    Huq, M. Saiful
    Fraass, Benedick A.
    Dunscombe, Peter B.
    Gibbons, John P., Jr.
    Ibbott, Geoffrey S.
    Mundt, Arno J.
    Mutic, Sasa
    Palta, Jatinder R.
    Rath, Frank
    Thomadsen, Bruce R.
    Williamson, Jeffrey F.
    Yorke, Ellen D.
    [J]. MEDICAL PHYSICS, 2016, 43 (07) : 4209 - 4262
  • [6] Japan Society of Medical Physics, 2018, STAND DOS ABS DOS WA, P203
  • [7] A failure modes and effects analysis study for gynecologic high-dose-rate brachytherapy
    Mayadev, Jyoti
    Dieterich, Sonja
    Harse, Rick
    Lentz, Susan
    Mathai, Mathew
    Boddu, Sunita
    Kern, Marianne
    Courquin, Jean
    Stern, Robin L.
    [J]. BRACHYTHERAPY, 2015, 14 (06) : 866 - 875
  • [8] Real-Time Verification of a High-Dose-Rate Iridium 192 Source Position Using a Modified C-Arm Fluoroscope
    Nose, Takayuki
    Chatani, Masashi
    Otani, Yuki
    Teshima, Teruki
    Kumita, Shinichirou
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 97 (04): : 858 - 865
  • [9] Quantitative Approach to Failure Mode and Effect Analysis for Linear Accelerator Quality Assurance
    O'Daniel, Jennifer C.
    Yin, Fang-Fang
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 98 (01): : 56 - 62
  • [10] Lessons learned from investigations of therapy misadministration events
    Ostrom, LT
    Rathbun, P
    Cumberlin, R
    Horton, J
    Castorf, R
    Leahy, TJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (01): : 227 - 234